65 resultados para OUTDOOR AIR
Resumo:
This study aimed to quantify Toxoplasma gondii in tissue samples of serologically positive chickens using real-time polymerase chain reaction (PCR). Of 65 chickens evaluated, 28 were positive for T. gondii antibodies. Brain and heart samples were collected from 26 seropositive chickens and DNA was extracted using Trizol® and amplified using real-time PCR with SYBR® Green. Parasite DNA was detected in 24 of the 26 samples analyzed; the number of positive tissue samples and the parasite quantity did not differ between tissue types. The results confirmed the analytical sensitivity of parasite detection in chicken tissue samples and demonstrated the possibility of using other molecular systems for genotypic analysis.
Resumo:
This work compared the behaviour of pre-parturient sows housed in intensive confined and outdoor systems, during the morning and afternoon prior to delivery. Eight sows were kept individually in farrowing crates or in paddocks with access to fresh pasture from 8 to 10 days before expected parturition. All outdoor sows built a nest within 24 hours before farrowing. On the morning and afternoon before farrowing they spent 6.5% of the time collecting grass and 7.5% of the time organizing the nest. Outdoor sows were observed more often than confined sows rooting (4.60% vs. 0.25%), feeding (10.2% vs. 3.0%), standing (51% vs. 13%) and walking (8% vs. 0%). Indoor sows redirected the nesting behaviour to other behaviours like attempts to dig the ground, nosing, biting and rooting parts of the crate, feeder or drinker, during 4.7% of the time. They also spent more time than outdoor sows inactive (85% vs. 60%), lying (72% vs. 41%), drinking (2.1% vs. 0.5%) and vacuum chewing (3.7% vs. 0.1%). The pre-parturient behaviour of sows was considerably affected by the husbandry system. The outdoor system appears to be more appropriate for the sows' welfare than the conventional confinement.
Resumo:
The objective of this study was to adapt a nonlinear model (Wang and Engel - WE) for simulating the phenology of maize (Zea mays L.), and to evaluate this model and a linear one (thermal time), in order to predict developmental stages of a field-grown maize variety. A field experiment, during 2005/2006 and 2006/2007 was conducted in Santa Maria, RS, Brazil, in two growing seasons, with seven sowing dates each. Dates of emergence, silking, and physiological maturity of the maize variety BRS Missões were recorded in six replications in each sowing date. Data collected in 2005/2006 growing season were used to estimate the coefficients of the two models, and data collected in the 2006/2007 growing season were used as independent data set for model evaluations. The nonlinear WE model accurately predicted the date of silking and physiological maturity, and had a lower root mean square error (RMSE) than the linear (thermal time) model. The overall RMSE for silking and physiological maturity was 2.7 and 4.8 days with WE model, and 5.6 and 8.3 days with thermal time model, respectively.
Resumo:
The objective of this study was to assess the development response of cultivated rice and red rice to different increases in minimum and maximum daily air temperatures, in Santa Maria, Rio Grande do Sul State, Brazil. One hundred years climate scenarios of temperatures 0, +1, +2, +3, +4, and +5ºC, with symmetric and asymmetric increases in minimum and maximum daily air temperatures were created, using the LARS-WG Weather Generator, and a 1969-2003 database. Nine cultivated rice genotypes (IRGA 421, IRGA 416, IRGA 417, IRGA 420, BRS 7 TAIM, BR-IRGA 409, EPAGRI 109, EEA 406 and a hybrid), and two red rice biotypes (awned black hull-ABHRR, and awned yellow hull-AYHRR) were used. The dates of panicle differentiation (R1), anthesis (R4), and all grains with brown hulls (R9) were estimated with a nonlinear simulation model. Overall, the duration of the emergence-R1 phase decreased, whereas the duration of the R1-R4 and R4-R9 phases most often increased, as temperature increased in the climate change scenarios. The simulated rice development response to elevated temperature was not the same, when the increase in minimum and maximum temperature was symmetric or asymmetric.
Resumo:
The objective of this work was to evaluate the effects of increased air-CO2 concentration on plant growth and on leaf-spot caused by Cylindrocladium candelabrumin Eucalyptus urophylla. Seedlings were cultivated for 30 days at 451, 645, 904, and 1,147 µmol mol-1 CO2 ; then, they were inoculated with the pathogen and kept under the same conditions for seven days. Increased CO2concentration increased plant height and shoot dry matter mass, and decreased disease incidence and severity. Stem diameter was not affected by the treatments. Increased concentrations of atmospheric CO2 favorably affect eucalypt growth and reduce leaf-spot severity.
Resumo:
A study was conducted to determine the possibility of cashew (Anacardium occidentale) cloning by air-layering and influence of IBA (indol-butyric acid) on this process. It was adopted a completely randomized design with 4 treatments, 10 air layers each and 4 replications, reaching 160 air layers. The IBA levels on the treatments were, as follow: 0, 1000, 3000 and 5000 mg.kg-1. It was evaluated: survival, callus and rooting percentage, average number and length of roots. The highest survival rate (67.5%) was registered with no growth regulator and IBA at 1000 mg.kg-1, while the best rooting percentage (82%) referred to 1000 mg.kg-1. In spite of average number and length of roots, the highest results were observed with IBA at 5000 mg.kg-1. IBA concentrations had no influence on cashew air-layering formation.
Resumo:
Objective The authors have sought to study the calibration of a clinical PKA meter (Diamentor E2) and a calibrator for clinical meters (PDC) in the Laboratory of Ionizing Radiation Metrology at Instituto de Energia e Ambiente - Universidade de São Paulo. Materials and Methods Different qualities of both incident and transmitted beams were utilized in conditions similar to a clinical setting, analyzing the influence from the reference dosimeter, from the distance between meters, from the filtration and from the average beam energy. Calibrations were performed directly against a standard 30 cm3 cylindrical chamber or a parallel-plate monitor chamber, and indirectly against the PDC meter. Results The lowest energy dependence was observed for transmitted beams. The cross calibration between the Diamentor E2 and the PDC meters, and the PDC presented the greatest propagation of uncertainties. Conclusion The calibration coefficient of the PDC meter showed to be more stable with voltage, while the Diamentor E2 calibration coefficient was more variable. On the other hand, the PDC meter presented greater uncertainty in readings (5.0%) than with the use of the monitor chamber (3.5%) as a reference.
Resumo:
The authors report a case of umbilical venous catheter malposition with air in the portal venous system in a preterm neonate. Initially, the hypothesis of necrotizing enterocolitis was considered, but the newborn progressed with no finding of disease and the air disappeared at follow-up radiography. The differential diagnosis of such a finding can avoid unnecessary clinical treatments.
Resumo:
The presence of low carbonyl compounds (C1-C4) and glutaraldehyde was observed in 14 work-locations in São Paulo city, Brazil, during January to July 1997 period. The quantification of other carbonyls was not possible due to a sampling artifact caused probably by undesirable reactions between the ambient ozone and the organic substract of C18 cartridge used to collect carbonyls. High indoor concentrations, compared to outdoor levels, were observed for all compounds. Formaldehyde was the most abundant species (29 ppb) followed by acetone and acetaldehyde (25 and 17 ppb) with a small contribution of propanal, crotonaldehyde and C4 isomers (0.7 to 1.5 ppb) when related to the total indoor carbonyls level. Glutaraldehyde was observed only in two different occupational locations in a hospital at high concentrations (121 ppb). In general, high individual carbonyl levels as well as total carbonyls levels found in several locations indicated an unpropitious air quality for the occupants of these non-industrial sites.
Resumo:
A sensitive and simple system was proposed for the in situ measurement of total aldehyde in outdoor or indoor ambient. The method is based on the use of a reagent drop as an useful interface to preconcentrate the sample prior to determination of total aldehyde as formaldehyde. The drop is formed at the tip of a cylindrical tube that contains two optical fibers placed on opposite sides and in contact with the reagent solution. One optical fiber carries the red light to the drop form a light emitting diode (LED). The transmitted light is measured by a second optical fiber/photodiode system. The analytical signal is read and converted into absorbance. The reagent solution of 3-methyl-2-benzothiazoline hydrazone (MBTH) forms a blue cation during reaction with formaldehyde that can be measured at 660 nm. Some aspects of kinetics reaction formation of dye were reevaluated. The formaldehyde reacts with MBTH and forms the azine in about 12 min. The oxidation of MBTH by Fe (III) and the formation of dye requires 3 min. The absorbance of the reagent drop is proportional to the sampling time and to the analyte concentration. The absorbance signal increases with increased sample gas flow until a maximum is reached then decreases until it forms a plateau. The proposed method was evaluated using both outdoor and indoor samples, and it was shown to viable provide an accurate measure of total aldehyde.
Resumo:
The present paper constitutes a synthesis of the results gotten during the five campaigns of air quality measurement in the years of 2003 and 2004 carried out in the Portuguese city of Viana do Castelo to characterise the reference situation and to accompany the Polis Programme, an urban re-qualification and environmental valorisation plan. The main objective of the monitoring programme consisted of the evaluation of atmospheric pollutants whose levels were susceptible of enhancement in the course of the urbanistic public works. The presented results refer to measurements performed in two distinct places of this city, comprising various consecutive days of acquisition that include, at least, one day of weekend.
Resumo:
Daily records of hospital admissions due to cardiorespiratory diseases and levels of PM10, SO2, CO, NO, NO2, and O3 were collected from 1999-2004 to evaluate the relationship between air pollution and morbidity in Lisbon. Generalised additive Poisson regression models were adopted, controlling for temperature, humidity, and both short and long-term seasonality. Significant positive associations, lagged by 1 or 2 days, were found between markers of traffic-related pollution (CO and NO2) and cardiocirculatory diseases in all age groups. Increased childhood emergency admissions for respiratory illness were significantly correlated with the 1-day lagged SO2 levels coming from industrial activities.
Resumo:
In this communication we describe the application of a conductive polymer gas sensor as an air pressure sensor. The device consists of a thin doped poly(4'-hexyloxy-2,5-biphenylene ethylene) (PHBPE) film deposited on an interdigitated metallic electrode. The sensor is cheap, easy to fabricate, lasts for several months, and is suitable for measuring air pressures in the range between 100 and 700 mmHg.
Resumo:
In this work, noise and aromatic hydrocarbons levels of indoor and outdoor karting circuits located in Rio de Janeiro were assessed. The sampling was perfomed using active charcoal cartridges, followed by solvent desorption and analysis by gas chromatography with mass spectrometry detection. This study demonstrated that the karting circuits, venues for entertainment, were a major source of air pollution with the detection of considerable amounts of these compounds (2.0 to 19.7 µg m-3 of benzene; 4.1 to 41.1 µg m-3 of toluene; 2.8 to 36.2 µg m-3 of ethylbenzene; 0.7 to 36.2 µg m-3 of xylenes) and high noise levels.
Resumo:
ABSTRACTWhile a number of papers have shown that subway systems have an impact on the air quality through the release of particulate matters, no information about the impact of such particles on tree attributes is available. Tree leaves from three different species from the exit side of a subway station in Rio de Janeiro, Brazil, were more asymmetrical than leaves from the entrance side. This leaves also presenting changes in leaves cuticle and chlorophyll content.