36 resultados para Non-constant coefficient diffusion equations


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work is presented and tested (for 106 adducts, mainly of the zinc group halides) two empirical equations supported in TG data to estimate the value of the metal-ligand bond dissociation enthalpy for adducts: <D> (M-O) = t i / g if t i < 420 K and <D> (M-O) = (t i / g ) - 7,75 . 10-2 . t i if t i > 420 K. In this empirical equations, t i is the thermodynamic temperature of the beginning of the thermal decomposition of the adduct, as determined by thermogravimetry, andg is a constant factor that is function of the metal halide considered and of the number of ligands, but is not dependant of the ligand itself. To half of the tested adducts the difference between experimental and calculated values was less than 5%. To about 80% of the tested adducts, the difference between the experimental (calorimetric) and the calculated (using the proposed equations) values are less than 15%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Theoretical and practical aspects concerning construction and use of a thin layer electrochemical cell are presented. Construction was realized by a simple technic and geometry was optimized in order to minimize the problems of electrical resistance. A well known redox system was studied ((Fe(III)(CN)6(3-)/Fe(II)(CN) 6(4-)) using two experimental methods, cyclic voltammetry and pulse chronopotentiometry. A numerical integration based-program was developed to calculate the voltammetric current in case of nernstian and non-nernstian behaviours and a diffusional model was used to treat the chronopotentiometric data. Thermodynamic (potential, concentration) and kinetic parameters (diffusion coefficient) were successfully determined for the redox system studied in this work.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, the effects of acrylamide (AAm), methylcellulose (MC) contents, pH and ionic strength on kinetic, network and hydrophilic properties of polyacrylamide and methylcellulose hydrogels were investigated. The hydrogels were characterized by evaluating of network [average molecular weight between crosslinks (M C), crosslink density (q) and the number of elastically effective chains (Ve)], and kinetic parameters [diffusional exponent (n), diffusion constant (k) and diffusion coefficient (D)]. Such properties were controlled by adjusting of the AAm, MC contents, pH and ionic strength factors. Due to high hydrophilicity and fast water-uptake, the PAAm-MC hydrogels can be considered as materials for potential applications in agricultural fields, mainly in controlled release of water or pesticides.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Al(C9H6ON)3.2.5H2O was precipitated from the mixture of an aqueous solution of aluminium ion and an acid solution of 8-hydroxyquinoline, by increasing the pH value to 9.5 with ammonia aqueous solution. The TG curves in nitrogen atmosphere present mass losses due to dehydration, partial volatilisation (sublimation plus vaporisation) of the anhydrous compound followed by thermal decomposition with the formation of a mixture of carbonaceous and residues. The relation between sublimation and vaporisation depends on the heating rate used. The non isothermic integral isoconventional methods as linear equations of Ozawa-Flynn-Wall and Kissinger-Akahira-Sunose (KAS) were used to obtain the kinetic parameters from TG and DTA curves, respectively. Despite the fact that both dehydration and volatilisation reactions follow the linearity by using both methods, only for the volatilisation reaction the validity condition, 20<= E/RT<= 50, was verified.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrode kinetics and study of 'transition state' with applied potential in case of [M - antibiotics - cephalothin] system were reported at pH = 7.30 ± 0.01 at suitable supporting electrolyte at 25.0ºC. The M = Co or Ni and antibiotics were doxycycline, chlortetracycline, oxytetracycline, tetracycline, minocycline, amoxicillin and chloramphenicol used as primary ligands and cephalothin as secondary ligand. Kinetic parameters viz. transfer coefficient (a), degree of irreversibility (l), diffusion coefficient (D) and rate constant (k) were determined. The values of a and k varied from 0.41 to 0.59 and 2.60 X 10-3 cm s-1 to 9.67 X 10-3 cm s-1 in case of [Co - antibiotics - cephalothin] system. In case of [Ni - antibiotics - cephalothin], a and k varied from 0.41 to 0.58 and 2.34 X 10-3 cm s-1 to 9.19 X 10-3 cm s-1 respectively confirmed that transition state behaves between oxidant and reductant response to applied potential and it adjusts it self in such a way that the same is located midway between dropping mercury electrode and solution interface. The values of rate constant confirmed the quasireversible nature of electrode processes. The stability constants (logb) of complexes were also determined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study aimed at evaluating the use of Artificial Neural Network to correlate the values resulting from chemical analyses of samples of coffee with the values of their sensory analyses. The coffee samples used were from the Coffea arabica L., cultivars Acaiá do Cerrado, Topázio, Acaiá 474-19 and Bourbon, collected in the southern region of the state of Minas Gerais. The chemical analyses were carried out for reducing and non-reducing sugars. The quality of the beverage was evaluated by sensory analysis. The Artificial Neural Network method used values from chemical analyses as input variables and values from sensory analysis as output values. The multiple linear regression of sensory analysis values, according to the values from chemical analyses, presented a determination coefficient of 0.3106, while the Artificial Neural Network achieved a level of 80.00% of success in the classification of values from the sensory analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is divided into two different parts. The first one provides a brief introduction to the fractal geometry with some simple illustrations in fluid mechanics. We thought it would be helpful to introduce the reader into this relatively new approach to mechanics that has not been sufficiently explored by engineers yet. Although in fluid mechanics, mainly in problems of percolation and binary flows, the use of fractals has gained some attention, the same is not true for solid mechanics, from the best of our knowledge. The second part deals with the mechanical behavior of thin wires subjected to very large deformations. It is shown that starting to a plausible conjecture it is possible to find global constitutive equations correlating geometrical end energy variables with the fractal dimension of the solid subjected to large deformations. It is pointed out the need to complement the present proposal with experimental work.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The flow structure of cold and ignited jets issuing into a co-flowing air stream was experimentally studied using a laser Doppler velocimeter. Methane was employed as the jet fluid discharging from circular and elliptic nozzles with aspect ratios varying from 1.29 to 1.60. The diameter of the circular nozzle was 4.6 mm and the elliptic nozzles had approximately the same exit area as that of the circular nozzle. These non-circular nozzles were employed in order to increase the stability of attached jet diffusion flames. The time-averaged velocity and r.m.s. value of the velocity fluctuation in the streamwise and transverse directions were measured over the range of co-flowing stream velocities corresponding to different modes of flame blowout that are identified as either lifted or attached flames. On the basis of these measurements, attempts were made to explain the existence of an apparent optimum aspect ratio for the blowout of attached flames observed at higher values of co-flowing stream velocities. The insensitivity of the blowout limits of lifted flames to nozzle geometry observed in our previous work at low co-flowing stream velocities was also explained. Measurements of the fuel concentration at the jet centerline indicated that the mixing process was enhanced with the 1.38 aspect ratio jet compared with the 1.60 aspect ratio jet. On the basis of the obtained experimental data, it was suggested that the higher blowout limits of attached flames for an elliptic jet of 1.38 aspect ratio was due to higher entrainment rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Mathematica system (version 4.0) is employed in the solution of nonlinear difusion and convection-difusion problems, formulated as transient one-dimensional partial diferential equations with potential dependent equation coefficients. The Generalized Integral Transform Technique (GITT) is first implemented for the hybrid numerical-analytical solution of such classes of problems, through the symbolic integral transformation and elimination of the space variable, followed by the utilization of the built-in Mathematica function NDSolve for handling the resulting transformed ODE system. This approach ofers an error-controlled final numerical solution, through the simultaneous control of local errors in this reliable ODE's solver and of the proposed eigenfunction expansion truncation order. For covalidation purposes, the same built-in function NDSolve is employed in the direct solution of these partial diferential equations, as made possible by the algorithms implemented in Mathematica (versions 3.0 and up), based on application of the method of lines. Various numerical experiments are performed and relative merits of each approach are critically pointed out.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper studies the effect of time delay on the active non-linear control of dynamically loaded flexible structures. The behavior of non-linear systems under state feedback control, considering a fixed time delay for the control force, is investigated. A control method based on non-linear optimal control, using a tensorial formulation and state feedback control is used. The state equations and the control forces are expressed in polynomial form and a performance index, quadratic in both state vector and control forces, is used. General polynomial representations of the non-linear control law are obtained and implemented for control algorithms up to the fifth order. This methodology is applied to systems with quadratic and cubic non-linearities. Strongly non-linear systems are tested and the effectiveness of the control system including a delay for the application of control forces is discussed. Numerical results indicate that the adopted control algorithm can be efficient for non-linear systems, chiefly in the presence of strong non-linearities but increasing time delay reduces the efficiency of the control system. Numerical results emphasize the importance of considering time delay in the project of active structural control systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We apply the Bogoliubov Averaging Method to the study of the vibrations of an elastic foundation, forced by a Non-ideal energy source. The considered model consists of a portal plane frame with quadratic nonlinearities, with internal resonance 1:2, supporting a direct current motor with limited power. The non-ideal excitation is in primary resonance in the order of one-half with the second mode frequency. The results of the averaging method, plotted in time evolution curve and phase diagrams are compared to those obtained by numerically integrating of the original differential equations. The presence of the saturation phenomenon is verified by analytical procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The human immunoglobulin lambda variable locus (IGLV) is mapped at chromosome 22 band q11.1-q11.2. The 30 functional germline v-lambda genes sequenced untill now have been subgrouped into 10 families (Vl1 to Vl10). The number of Vl genes has been estimated at approximately 70. This locus is formed by three gene clusters (VA, VB and VC) that encompass the variable coding genes (V) responsible for the synthesis of lambda-type Ig light chains, and the Jl-Cl cluster with the joining segments and the constant genes. Recently the entire variable lambda gene locus was mapped by contig methodology and its one- megabase DNA totally sequenced. All the known functional V-lambda genes and pseudogenes were located. We screened a human genomic DNA cosmid library and isolated a clone with an insert of 37 kb (cosmid 8.3) encompassing four functional genes (IGLV7S1, IGLV1S1, IGLV1S2 and IGLV5a), a pseudogene (VlA) and a vestigial sequence (vg1) to study in detail the positions of the restriction sites surrounding the Vl genes. We generated a high resolution restriction map, locating 31 restriction sites in 37 kb of the VB cluster, a region rich in functional Vl genes. This mapping information opens the perspective for further RFLP studies and sequencing

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the effect of first morning urinary volume (collected on three different non-consecutive days), fasting blood glucose (determined on the first and third days of urine collection), and glycosylated hemoglobin (determined on the first and third days of urine collection) on the albumin concentration in first morning urine samples collected on three different days. We found 3.6% asymptomatic bacteriuria in the urine samples; therefore, every urine sample must be tested to exclude infection. One hundred and fifty urine samples were provided by 50 IDDM patients aged 21.9 ± 7 (12-38) years with a disease duration of 6.8 ± 5.8 (0.4-31) years attending the Diabetes Clinic at the State University Hospital of Rio de Janeiro. There were no differences in albumin concentration (6.1 vs 5.8 vs 6.2 µg/ml; P = NS) or urinary volume (222.5 vs 210 vs 200 ml) between the three samples. In addition, there were no differences in fasting blood glucose (181.9 ± 93.6 vs 194.6 ± 104.7 mg%; P = NS) or glycosylated hemoglobin (HbA1)(8.4 ± 1.3 vs 8.8 ± 1.5%; P = NS) between the first and third blood samples. Six patients (group 1) had a mean urinary albumin concentration of more than 20 µg/ml for the three urine samples. This group was compared with the 44 patients (group 2) with a mean urinary albumin concentration for the three urine samples of less than 20 µg/ml. No difference was found between groups 1 and 2 in relation to fasting blood glucose (207.1 ± 71.7 vs 187.6 ± 84.6 mg/dl), HbA1 (8.1 ± 0.9 vs 8.6 ± 1.1%) or urinary volume [202 (48.3-435) vs 246 (77.3-683.3) ml]. Stepwise multiple regression analysis with albumin concentration of first morning urine samples as the dependent variable, and urinary volume, fasting blood glucose and glycosylated hemoglobin as independent variables, showed that only 12% (P = 0.01) of the albumin concentration could be accounted for by the independent effect of morning urine volume on the first day of urine collection. No urine samples showed a change in the cutoff level of 20 µg/ml of albumin concentration as the result of volume. Fasting blood glucose and glycosylated hemoglobin did not influence the urinary albumin concentration. Considerable variability in urinary albumin concentration was found in the three morning urine samples with a mean intraindividual coefficient variation of 56%. In conclusion, in the present study, urinary volume had a minimal, though not constant, effect on first morning urinary albumin concentration. Day-to-day metabolic and clinical control of IDDM patients, except probably for ketoacidosis, should not contraindicate microalbuminuria screening in first morning urine samples

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work was to compare the performance of isotope-selective non-dispersive infrared spectrometry (IRIS) for the 13C-urea breath test with the combination of the 14C-urea breath test (14C-UBT), urease test and histologic examination for the diagnosis of H. pylori (HP) infection. Fifty-three duodenal ulcer patients were studied. All patients were submitted to gastroscopy to detect HP by the urease test, histologic examination and 14C-UBT. To be included in the study the results of the 3 tests had to be concordant. Within one month after admission to the study the patients were submitted to IRIS with breath samples collected before and 30 min after the ingestion of 75 mg 13C-urea dissolved in 200 ml of orange juice. The samples were mailed and analyzed 11.5 (4-21) days after collection. Data were analyzed statistically by the chi-square and Mann-Whitney test and by the Spearman correlation coefficient. Twenty-six patients were HP positive and 27 negative. There was 100% agreement between the IRIS results and the HP status determined by the other three methods. Using a cutoff value of delta-over-baseline (DOB) above 4.0 the IRIS showed a mean value of 19.38 (minimum = 4.2, maximum = 41.3, SD = 10.9) for HP-positive patients and a mean value of 0.88 (minimum = 0.10, maximum = 2.5, SD = 0.71) for negative patients. Using a cutoff value corresponding to 0.800% CO2/weight (kg), the 14C-UBT showed a mean value of 2.78 (minimum = 0.89, maximum = 5.22, SD = 1.18) in HP-positive patients. HP-negative patients showed a mean value of 0.37 (minimum = 0.13, maximum = 0.77, SD = 0.17). IRIS is a low-cost, easy to manage, highly sensitive and specific test for H. pylori detection. Storing and mailing the samples did not interfere with the performance of the test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is widely accepted that the classical constant-temperature hot-plate test is insensitive to cyclooxygenase inhibitors. In the current study, we developed a variant of the hot-plate test procedure (modified hot-plate (MHP) test) to measure inflammatory nociception in freely moving rats and mice. Following left and right hind paw stimulation with a phlogogen and vehicle, respectively, the animals were placed individually on a hot-plate surface at 51ºC and the withdrawal latency for each paw was determined simultaneously in measurements performed at 15, 60, 180, and 360 min post-challenge. Plantar stimulation of rats (250 and 500 µg/paw) and mice (125-500 µg/paw) with carrageenan led to a rapid hyperalgesic response of the ipsilateral paw that reached a plateau from 15 to 360 min after challenge. Pretreatment with indomethacin (4 mg/kg, ip) inhibited the phenomenon at all the times analyzed. Similarly, plantar stimulation of rats and mice with prostaglandin E2 (0.5 and 1 µg/paw) also resulted in rapid hyperalgesia which was first detected 15 min post-challenge. Finally, we observed that the MHP test was more sensitive than the classical Hargreaves' test, being able to detect about 4- and 10-fold lower doses of prostaglandin E2 and carrageenan, respectively. In conclusion, the MHP test is a simple and sensitive method for detecting peripheral hyperalgesia and analgesia in rats and mice. This test represents a low-cost alternative for the study of inflammatory pain in freely moving animals.