140 resultados para NIRS. Plum. Multivariate calibration. Variables selection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, a partial least squares regression routine was used to develop a multivariate calibration model to predict the chemical oxygen demand (COD) in substrates of environmental relevance (paper effluents and landfill leachates) from UV-Vis spectral data. The calibration models permit the fast determination of the COD with typical relative errors lower by 10% with respect to the conventional methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since the last decade, the combined use of chemometrics and molecular spectroscopic techniques has become a new alternative for direct drug determination, without the need of physical separation. Among the new methodologies developed, the application of PARAFAC in the decomposition of spectrofluorimetric data should be highlighted. The first objective of this article is to describe the theoretical basis of PARAFAC. For this purpose, a discussion about the order of chemometric methods used in multivariate calibration and the development of multi-dimensional methods is presented first. The other objective of this article is to divulge for the Brazilian chemical community the potential of the combination PARAFAC/spectrofluorimetry for the determination of drugs in complex biological matrices. For this purpose, two applications aiming at determining, respectively, doxorrubicine and salicylate in human plasma are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chemometric activities in Brazil are described according to three phases: before the existence of microcomputers in the 1970s, through the initial stages of microcomputer use in the 1980s and during the years of extensive microcomputer applications of the ´90s and into this century. Pioneering activities in both the university and industry are emphasized. Active research areas in chemometrics are cited including experimental design, pattern recognition and classification, curve resolution for complex systems and multivariate calibration. New trends in chemometrics, especially higher order methods for treating data, are emphasized.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Least-squares support vector machines (LS-SVM) were used as an alternative multivariate calibration method for the simultaneous quantification of some common adulterants found in powdered milk samples, using near-infrared spectroscopy. Excellent models were built using LS-SVM for determining R², RMSECV and RMSEP values. LS-SVMs show superior performance for quantifying starch, whey and sucrose in powdered milk samples in relation to PLSR. This study shows that it is possible to determine precisely the amount of one and two common adulterants simultaneously in powdered milk samples using LS-SVM and NIR spectra.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, the artificial neural networks (ANN) and partial least squares (PLS) regression were applied to UV spectral data for quantitative determination of thiamin hydrochloride (VB1), riboflavin phosphate (VB2), pyridoxine hydrochloride (VB6) and nicotinamide (VPP) in pharmaceutical samples. For calibration purposes, commercial samples in 0.2 mol L-1 acetate buffer (pH 4.0) were employed as standards. The concentration ranges used in the calibration step were: 0.1 - 7.5 mg L-1 for VB1, 0.1 - 3.0 mg L-1 for VB2, 0.1 - 3.0 mg L-1 for VB6 and 0.4 - 30.0 mg L-1 for VPP. From the results it is possible to verify that both methods can be successfully applied for these determinations. The similar error values were obtained by using neural network or PLS methods. The proposed methodology is simple, rapid and can be easily used in quality control laboratories.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work a multivariate spectroscopic methodology is proposed for quantitative determination of sulfamethoxazole and trimethoprim in pharmaceutical associations. The multivariate model was developed by partial least-squares regression, using twenty synthetic mixtures and the spectral region between 190 and 350 nm. In the validation stage, which involved the analysis of five synthetic mixtures, prediction errors lower that 3% were observed. The predictive capacity of the multivariate models is seriously affected by spectral changes induced by pH variations, a fact that acquires a great significance in the analysis of real samples (pharmaceuticals) that contain chemical additives.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diffuse reflectance near-infrared (DR-NIR) spectroscopy associated with partial least squares (PLS) multivariate calibration is proposed for a direct, non-destructive, determination of total nitrogen in wheat leaves. The procedure was developed for an Analytical Instrumental Analysis course, carried out at the Institute of Chemistry of the State University of Campinas. The DR-NIR results are in good agreement with those obtained by the Kjeldhal standard procedure, with a relative error of less than ± 3% and the method may be used for teaching purposes as well as for routine analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work an analytical methodology for the determination of relevant physicochemical parameters of prato cheese is reported, using infrared spectroscopy (DRIFT) and partial least squares regression (PLS). Several multivariate models were developed, using different spectral regions and preprocessing routines. In general, good precision and accuracy was observed for all studied parameters (fat, protein, moisture, total solids, ashes and pH) with standard deviations comparable with those provided by the conventional methodologies. The implantation of this multivariate routine involves significant analytical advantages, including reduction of cost and time of analysis, minimization of human errors, and elimination of chemical residues.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The validation of an analytical procedure must be certified through the determination of parameters known as figures of merit. For first order data, the acuracy, precision, robustness and bias is similar to the methods of univariate calibration. Linearity, sensitivity, signal to noise ratio, adjustment, selectivity and confidence intervals need different approaches, specific for multivariate data. Selectivity and signal to noise ratio are more critical and they only can be estimated by means of the calculation of the net analyte signal. In second order calibration, some differentes approaches are necessary due to data structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective of the present work is represented by the characterization of the physical properties of industrial kraft paper (i.e. transversal and longitudinal tear resistance, transversal traction resistance, bursting or crack resistance, longitudinal and transversal compression resistance (SCT (Compressive Strength Tester) and compression resistance (RCT-Ring Crush Test)) by near infrared spectroscopy associated to partial least squares regression. Several multivariate models were developed, many of them with high prevision capacity. In general, low prevision errors were observed and regression coefficients that are comparable with those provided by conventional standard methodologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ten common doubts of chemistry students and professionals about their statistical applications are discussed. The use of the N-1 denominator instead of N is described for the standard deviation. The statistical meaning of the denominators of the root mean square error of calibration (RMSEC) and root mean square error of validation (RMSEV) are given for researchers using multivariate calibration methods. The reason why scientists and engineers use the average instead of the median is explained. Several problematic aspects about regression and correlation are treated. The popular use of triplicate experiments in teaching and research laboratories is seen to have its origin in statistical confidence intervals. Nonparametric statistics and bootstrapping methods round out the discussion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this manuscript was to show the basic concepts and practical application of Partial Least Squares (PLS) as a tutorial, using the Matlab computing environment for beginners, undergraduate and graduate students. As a practical example, the determination of the drug paracetamol in commercial tablets using Near-Infrared (NIR) spectroscopy and Partial Least Squares (PLS) regression was shown, an experiment that has been successfully carried out at the Chemical Institute of Campinas State University for chemistry undergraduate course students to introduce the basic concepts of multivariate calibration in a practical way.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Several researchers seek methods for the selection of homogeneous groups of animals in experimental studies, a fact justified because homogeneity is an indispensable prerequisite for casualization of treatments. The lack of robust methods that comply with statistical and biological principles is the reason why researchers use empirical or subjective methods, influencing their results. Objective: To develop a multivariate statistical model for the selection of a homogeneous group of animals for experimental research and to elaborate a computational package to use it. Methods: The set of echocardiographic data of 115 male Wistar rats with supravalvular aortic stenosis (AoS) was used as an example of model development. Initially, the data were standardized, and became dimensionless. Then, the variance matrix of the set was submitted to principal components analysis (PCA), aiming at reducing the parametric space and at retaining the relevant variability. That technique established a new Cartesian system into which the animals were allocated, and finally the confidence region (ellipsoid) was built for the profile of the animals’ homogeneous responses. The animals located inside the ellipsoid were considered as belonging to the homogeneous batch; those outside the ellipsoid were considered spurious. Results: The PCA established eight descriptive axes that represented the accumulated variance of the data set in 88.71%. The allocation of the animals in the new system and the construction of the confidence region revealed six spurious animals as compared to the homogeneous batch of 109 animals. Conclusion: The biometric criterion presented proved to be effective, because it considers the animal as a whole, analyzing jointly all parameters measured, in addition to having a small discard rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to evaluate the efficiency of simultaneous selection (selection indices) using estimated genetic gains in yellow passion fruit and to make a comparison between the methodologies of Mulamba & Mock and Elston. The study was conducted with 26 sib progenies of yellow passion fruit for intrinsic production characteristics including fruit number, fruit mass, fruit length and diameter, and for the fruit characteristics skin thickness, soluble solids and acidity. Two methodologies were applied: first, in the joint analysis of fruit characteristics and of intrinsic production characteristics in a single phase of selection; and second, in the analysis in two phases, in which priority was given to the intrinsic production characteristics in the first phase, and later, in the second phase, the best fruit characteristics were chosen among the progenies of the first phase. The analysis of variance was applied to the data to detect genetic variability among progenies. The Elston's selection indice was unable to provide distribution of genetic gains consistent with the purposes of the study, as it selected a single progeny of passion fruit. However, the index based on the sum of ranks of Mulamba & Mock was more suitable, as it provided a balanced distribution of gains, selecting a larger number of progenies. The methodology of selection using indices is advantageous in passion fruit, since it contributes to higher genetic gains for all the traits evaluated, and the selection in a single phase was proved efficient for progeny selection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Associations between socio-demographic factors, water contact patterns and Schistosoma mansoni infection were investigated in 506 individuals (87% of inhabitants over 1 year of age) in an endemic area in Brazil (Divino), aiming at determining priorities for public health measures to prevent the infection. Those who eliminated S. mansoni eggs (n = 198) were compared to those without eggs in the stools (n = 308). The following explanatory variables were considered: age, sex, color, previous treatment with schistosomicide, place of birth, quality of the houses, water supply for the household, distance from houses to stream, and frequency and reasons for water contact. Factors found to be independently associated with the infection were age (10-19 and > 20 yrs old), and water contact for agricultural activities, fishing, and swimming or bathing (Adjusted relative odds = 5.0, 2.4, 3.2, 2.1 and 2.0, respectively). This suggests the need for public health measures to prevent the infection, emphasizing water contact for leisure and agricultural activities in this endemic area.