87 resultados para Multivariate Monitoring
Resumo:
Introduction The aim of the present study was to assess the polymerase chain reaction (PCR) as a method for detecting Trypanosoma cruzi infection in triatomines that had been previously determined by microscopic examination in the State of Mato Grosso do Sul, Brazil. Methods In total, 515 specimens were collected. Material from the digestive tract of each triatomine was analyzed for the presence of T. cruzi by microscopic examination and PCR using the 121/122 primer set. Results Among the 515 specimens tested, 58 (11.3%) were positive by microscopy and 101 (19.61%) were positive by PCR and there was an association between the results of the techniques (χ2 = 53.354, p = 0.001). The main species of triatomine identified was T. sordida (95.5%) Conclusions The use of PCR in entomological surveillance may contribute to a better assessment of the occurrence of T. cruzi in triatomine populations.
Resumo:
A prospective study was conducted to determine if standardized vancomycin doses could produce adequate serum concentrations in 25 term newborn infants with sepsis. Purpose: The therapeutic response of neonatal sepsis by Staphylococcus sp. treated with vancomycin was evaluated through serum concentrations of vancomycin, serum bactericidal titers (SBT), and minimum inhibitory concentration (MIC). METHOD: Vancomycin serum concentrations were determined by the fluorescence polarization immunoassay technique , SBT by the macro-broth dilution method, and MIC by diffusion test in agar . RESULTS: Thirteen newborn infants (59.1%) had adequate peak vancomycin serum concentrations (20--40 mg/mL) and one had peak concentration with potential ototoxicity risk (>40 µg/mL). Only 48% had adequate trough concentrations (5--10 mg/mL), and seven (28%) had a potential nephrotoxicity risk (>10 µg/mL). There was no significant agreement regarding normality for peak and trough vancomycin method (McNemar test : p = 0.7905). Peak serum vancomycin concentrations were compared with the clinical evaluation (good or bad clinical evolution) of the infants, with no significant difference found (U=51.5; p=0.1947). There was also no significant difference between the patients' trough concentrations and good or bad clinical evolution (U = 77.0; p=0.1710). All Staphylococcus isolates were sensitive to vancomycin according to the MIC. Half of the patients with adequate trough SBT (1/8), also had adequate trough vancomycin concentrations and satisfactory clinical evolution. CONCLUSIONS: Recommended vancomycin schedules for term newborn infants with neonatal sepsis should be based on the weight and postconceptual age only to start antimicrobial therapy. There is no ideal pattern of vancomycin dosing; vancomycin dosages must be individualized. SBT interpretation should be made in conjunction with the patient's clinical presentation and vancomycin serum concentrations. Those laboratory and clinical data favor elucidation of the probable cause of patient's bad evolution, which would facilitate drug adjustment and reduce the risk of toxicity or failing to achieve therapeutic doses.
Resumo:
INTRODUCTION: Peak and trough serum concentrations of vancomycin were determined in term newborn infants with confirmed or suspected Staphylococcus sp sepsis by high performance liquid chromatography and flourescence polarization immunoassay. OBJECTIVE: To statistically compare the results of the high performance liquid chromatography and flourescence polarization immunoassay techniques for measuring serum vancomycin concentrations. METHODS: Eighteen peak and 20 trough serum samples were assayed for vancomycin concentrations using high performance liquid chromatography and flourescence polarization immunoassay from October 1995 to October 1997. RESULTS: The linear correlation coefficients for high performance liquid chromatography and flourescence polarization immunoassay were 0.27 (peak, P = 0.110) and 0.26 (trough, P = 0.1045) respectively, which were not statistically significant. CONCLUSION: There was wide variation in serum vancomycin concentrations determined by high performance liquid chromatography as compared with those determined by flourescence polarization immunoassay. There was no recognizable pattern in the variability; in an apparently random fashion, the high performance liquid chromatography measurement was sometimes substantially higher than the flourescence polarization immunoassay measurement, and at other times it was substantially lower.
Resumo:
The use of substitute groups in biomonitoring programs has been proposed to minimize the high financial costs and time for samples processing. The objectives of this study were to evaluate the correlation between (i) the spatial distribution among the major zooplankton groups (cladocerans, copepods, rotifers, and testaceans protozoa), (ii) the data of density and presence/absence of species, and (iii) the data of species, genera, and families from samples collected in the Lago Grande do Curuai, Pará, Brazil. A total of 55 sample of the zooplanktonic community was collected, with 28 samples obtained in March and 27 in September, 2013. The agreement between the different sets of data was assessed using Mantel and Procrustes tests. Our results indicated high correlations between genus level and species level and high correlations between presence/absence of species and abundance, regardless of the seasonal period. These results suggest that zooplankton community could be incorporated in a long-term monitoring program at relatively low financial and time costs.
Resumo:
OBJECTIVE: A double-blind, placebo-controlled multicenter study involving 34 centers from different Brazilian regions was performed to evaluate the antihypertensive efficacy and tolerability of trandolapril, an angiotensin I converting enzyme inhibitor, in the treatment of mild-to-moderate systemic arterial hypertension. METHODS: Of 262 patients enrolled in this study, 127 were treated with trandolapril 2 mg/day for 8 consecutive weeks, and the remaining 135 patients received placebo for the same period of time. Reduction in blood pressure (BP) and the occurrence of adverse events during this period were evaluated in both groups. RESULTS: Significant reductions in both systolic and diastolic pressures were observed in patients treated with trandolapril when compared with those on placebo. Antihypertensive efficacy was achieved in 57.5% of the patients on trandolapril and in 42% of these normal values of BP were obtained. The efficacy of trandolapril was similar in all centers, regardless of the area of the country. In a subset of 30 patients who underwent ABPM, responders showed a significant hypotensive effect to trandolapril throughout the 24 hour day. The adverse event profile was similar in both trandolapril and placebo groups. CONCLUSION: Our results demonstrate, for the first time in a large group of hypertensive patients from different regions in Brazil, good efficacy and tolerability of trandolapril during treatment of mild-to-moderate essential systemic hypertension.
Resumo:
OBJETIVE: To assess the hemodynamic profile of cardiac surgery patients with circulatory instability in the early postoperative period (POP). METHODS: Over a two-year period, 306 patients underwent cardiac surgery. Thirty had hemodynamic instability in the early POP and were monitored with the Swan-Ganz catheter. The following parameters were evaluated: cardiac index (CI), systemic and pulmonary vascular resistance, pulmonary shunt, central venous pressure (CVP), pulmonary capillary wedge pressure (PCWP), oxygen delivery and consumption, use of vasoactive drugs and of circulatory support. RESULTS: Twenty patients had low cardiac index (CI), and 10 had normal or high CI. Systemic vascular resistance was decreased in 11 patients. There was no correlation between oxygen delivery (DO2) and consumption (VO2), p=0.42, and no correlation between CVP and PCWP, p=0.065. Pulmonary vascular resistance was decreased in 15 patients and the pulmonary shunt was increased in 19. Two patients with CI < 2L/min/m² received circulatory support. CONCLUSION: Patients in the POP of cardiac surgery frequently have a mixed shock due to the systemic inflammatory response syndrome (SIRS). Therefore, invasive hemodynamic monitoring is useful in handling blood volume, choice of vasoactive drugs, and indication for circulatory support.
Resumo:
OBJECTIVE: To evaluate the influence of the siesta in ambulatory blood pressure (BP) monitoring and in cardiac structure parameters. METHODS: 1940 ambulatory arterial blood pressure monitoring tests were analyzed (Spacelabs 90207, 15/15 minutes from 7:00 to 22:00 hours and 20/20 minutes from 22:01 to 6.59hours) and 21% of the records indicated that the person had taken a siesta (263 woman, 52±14 years). The average duration of the siesta was 118±58 minutes. RESULTS: (average ± standard deviation) The average of systolic/diastolic pressures during wakefulness, including the napping period, was less than the average for the period not including the siesta (138±16/85±11 vs 139±16/86±11 mmHg, p<0.05); 2) pressure loads during wakefulness including the siesta, were less than those observed without the siesta); 3) the averages of nocturnal sleep blood pressures were similar to those of the siesta, 4) nocturnal sleep pressure drops were similar to those in the siesta including wakefulness with and without the siesta; 5) the averages of BP in men were higher (p<0.05) during wakefulness with and without the siesta, during the siesta and nocturnal sleep in relation to the average obtained in women; 6) patients with a reduction of 0- 5% during the siesta had thickening of the interventricular septum and a larger posterior wall than those with a reduction during the siesta >5%. CONCLUSION: The siesta influenced the heart structure parameters and from a statistical point of view the average of systolic and diastolic pressures and the respective pressure loads of the wakeful period.
Resumo:
OBJECTIVE: To assess the association between microalbuminuria with ambulatory blood pressure monitoring in normotensive individuals with insulin-dependent diabetes mellitus. METHODS: Thirty-seven patients underwent determination of the rate of urinary excretion of albumin through radioimmunoassay and ambulatory blood pressure monitoring. Their mean age was 26.5±6.7 years, and the mean duration of their disease was 8 (1-34) years. Microalbuminuria was defined as urinary excretion of albumin > or = 20 and <200µg/min in at least 2 out of 3 urine samples. RESULTS: Nine (24.3%) patients were microalbuminuric. Ambulatory blood pressure monitoring in the microalbuminuric patients had higher mean pressure values, mainly the systolic pressure, during sleep as compared with that in the normoalbuminuric patients (120.1±8.3 vs 110.8±7.1 mmHg; p=0.007). The pressure load was higher in the microalbuminuric individuals, mainly the systolic pressure load during wakefulness [6.3 (2.9-45.9) vs 1.6 (0-16%); p=0.001]. This was the variable that better correlated with the urinary excretion of albumin (rS=0.61; p<0.001). Systolic pressure load >50% and diastolic pressure load > 30% during sleep was associated with microalbuminuria (p=0.008). The pressure drop during sleep did not differ between the groups. CONCLUSION: Microalbuminuric normotensive insulin-dependent diabetic patients show greater mean pressure value and pressure load during ambulatory blood pressure monitoring, and these variables correlate with urinary excretion of albumin.
Resumo:
OBJECTIVE: To assess the influence of the quality of sleep on the nocturnal physiological drop in blood pressure during ambulatory blood pressure monitoring. METHODS: We consecutively assessed ambulatory blood pressure monitoring, the degree of tolerance for the examination, and the quality of sleep in 168 patients with hypertension or with the suspected "white-coat" effect. Blood pressure fall during sleep associated with a specific questionnaire and an analogical visual scale of tolerance for ambulatory blood pressure monitoring were used to assess usual sleep and sleep on the day of examination. Two specialists in sleep disturbances classified the patients into 2 groups: those with normal sleep and those with abnormal sleep. RESULTS: Fifty-nine (35 %) patients comprised the abnormal sleep group. Findings regarding the quality of sleep on the day of ambulatory blood pressure monitoring as compared with those regarding the quality of sleep on a usual day were different and were as follows, respectively: total duration of sleep (-12.4±4.7 versus -42.2±14.9 minutes, P=0.02), latency of sleep (0.4±2.7 versus 17±5.1 minutes, P<0.001), number of awakenings (0.1±0.1 versus 1.35±0.3 times, P<0.001), and tolerance for ambulatory blood pressure monitoring (8±0.2 versus 6.7±0.35, P=0.035). An abnormal drop in blood pressure during sleep occurred in 20 (18%) patients in the normal sleep group and in 14 (24%) patients in the abnormal sleep group, P=0.53. CONCLUSION: Ambulatory blood pressure monitoring causes sleep disturbances in some patients, and a positive association between quality of sleep and tolerance for the examination was observed.
Resumo:
OBJECTIVE: To assess the prevalence of white-coat normortension, white-coat hypertension, and white-coat effect. METHODS: We assessed 670 medical records of patients from the League of Hypertension of the Hospital das Clínicas of the Medical School of the University of São Paulo. White-coat hypertension (blood pressure at the medical office: mean of 3 measurements with the oscillometric device ³140 or ³90 mmHg, or both, and ambulatory blood pressure monitoring mean during wakefulness < 135/85) and white-coat normotension (office blood pressure < 140/90 and blood pressure during wakefulness on ambulatory blood pressure monitoring ³ 135/85) were analyzed in 183 patients taking no medication. The white-coat effect (difference between office and ambulatory blood pressure > 20 mmHg for systolic and 10 mmHg for diastolic) was analyzed in 487 patients on treatment, 374 of whom underwent multivariate analysis to identify the variables that better explain the white-coat effect. RESULTS: Prevalence of white-coat normotension was 12%, prevalence of white-coat hypertension was 20%, and prevalence of the white-coat effect was 27%. A significant correlation (p<0.05) was observed between white-coat hypertension and familial history of hypertension, and between the white-coat effect and sex, severity of the office diastolic blood pressure, and thickness of left ventricular posterior wall. CONCLUSION: White-coat hypertension, white-coat normotension, and white-coat effect should be considered in the diagnosis of hypertension.
Resumo:
Background: The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM). Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM) as gold-standard and measurements taken before morning micturition (BM) and in the afternoon (AM), for the best diagnosis of systemic arterial hypertension (SAH), and their association with prognostic markers. Methods: After undergoing 24-hour wakefulness ABPM, 158 participants (84 women) were randomized for 3- or 5-day HBPM. Two variations of the 3-day protocol were considered: with measurements taken before morning micturition and in the afternoon (BM+AM); and with post-morning-micturition and evening measurements (PM+EM). All patients underwent echocardiography (for left ventricular hypertrophy - LVH) and urinary albumin measurement (for microalbuminuria - MAU). Result: Kappa statistic for the diagnosis of SAH between wakefulness-ABPM and standard 3-day HBPM, 3-day HBPM (BM+AM) and (PM+EM), and 5-day HBPM were 0.660, 0.638, 0.348 and 0.387, respectively. The values of sensitivity of (BM+AM) versus (PM+EM) were 82.6% × 71%, respectively, and of specificity, 84.8% × 74%, respectively. The positive and negative predictive values were 69.1% × 40% and 92.2% × 91.2%, respectively. The comparisons of intraclass correlations for the diagnosis of LVH and MAU between (BM+AM) and (PM+EM) were 0.782 × 0.474 and 0.511 × 0.276, respectively. Conclusions: The 3 day-HBPM protocol including measurements taken before morning micturition and during work in the afternoon showed the best agreement with SAH diagnosis and the best association with prognostic markers.
Resumo:
Background: Several researchers seek methods for the selection of homogeneous groups of animals in experimental studies, a fact justified because homogeneity is an indispensable prerequisite for casualization of treatments. The lack of robust methods that comply with statistical and biological principles is the reason why researchers use empirical or subjective methods, influencing their results. Objective: To develop a multivariate statistical model for the selection of a homogeneous group of animals for experimental research and to elaborate a computational package to use it. Methods: The set of echocardiographic data of 115 male Wistar rats with supravalvular aortic stenosis (AoS) was used as an example of model development. Initially, the data were standardized, and became dimensionless. Then, the variance matrix of the set was submitted to principal components analysis (PCA), aiming at reducing the parametric space and at retaining the relevant variability. That technique established a new Cartesian system into which the animals were allocated, and finally the confidence region (ellipsoid) was built for the profile of the animals’ homogeneous responses. The animals located inside the ellipsoid were considered as belonging to the homogeneous batch; those outside the ellipsoid were considered spurious. Results: The PCA established eight descriptive axes that represented the accumulated variance of the data set in 88.71%. The allocation of the animals in the new system and the construction of the confidence region revealed six spurious animals as compared to the homogeneous batch of 109 animals. Conclusion: The biometric criterion presented proved to be effective, because it considers the animal as a whole, analyzing jointly all parameters measured, in addition to having a small discard rate.
Resumo:
AbstractBackground:30-40% of cardiac resynchronization therapy cases do not achieve favorable outcomes.Objective:This study aimed to develop predictive models for the combined endpoint of cardiac death and transplantation (Tx) at different stages of cardiac resynchronization therapy (CRT).Methods:Prospective observational study of 116 patients aged 64.8 ± 11.1 years, 68.1% of whom had functional class (FC) III and 31.9% had ambulatory class IV. Clinical, electrocardiographic and echocardiographic variables were assessed by using Cox regression and Kaplan-Meier curves.Results:The cardiac mortality/Tx rate was 16.3% during the follow-up period of 34.0 ± 17.9 months. Prior to implantation, right ventricular dysfunction (RVD), ejection fraction < 25% and use of high doses of diuretics (HDD) increased the risk of cardiac death and Tx by 3.9-, 4.8-, and 5.9-fold, respectively. In the first year after CRT, RVD, HDD and hospitalization due to congestive heart failure increased the risk of death at hazard ratios of 3.5, 5.3, and 12.5, respectively. In the second year after CRT, RVD and FC III/IV were significant risk factors of mortality in the multivariate Cox model. The accuracy rates of the models were 84.6% at preimplantation, 93% in the first year after CRT, and 90.5% in the second year after CRT. The models were validated by bootstrapping.Conclusion:We developed predictive models of cardiac death and Tx at different stages of CRT based on the analysis of simple and easily obtainable clinical and echocardiographic variables. The models showed good accuracy and adjustment, were validated internally, and are useful in the selection, monitoring and counseling of patients indicated for CRT.
Resumo:
AbstractBackground:The recording of arrhythmic events (AE) in renal transplant candidates (RTCs) undergoing dialysis is limited by conventional electrocardiography. However, continuous cardiac rhythm monitoring seems to be more appropriate due to automatic detection of arrhythmia, but this method has not been used.Objective:We aimed to investigate the incidence and predictors of AE in RTCs using an implantable loop recorder (ILR).Methods:A prospective observational study conducted from June 2009 to January 2011 included 100 consecutive ambulatory RTCs who underwent ILR and were followed-up for at least 1 year. Multivariate logistic regression was applied to define predictors of AE.Results:During a mean follow-up of 424 ± 127 days, AE could be detected in 98% of patients, and 92% had more than one type of arrhythmia, with most considered potentially not serious. Sustained atrial tachycardia and atrial fibrillation occurred in 7% and 13% of patients, respectively, and bradyarrhythmia and non-sustained or sustained ventricular tachycardia (VT) occurred in 25% and 57%, respectively. There were 18 deaths, of which 7 were sudden cardiac events: 3 bradyarrhythmias, 1 ventricular fibrillation, 1 myocardial infarction, and 2 undetermined. The presence of a long QTc (odds ratio [OR] = 7.28; 95% confidence interval [CI], 2.01–26.35; p = 0.002), and the duration of the PR interval (OR = 1.05; 95% CI, 1.02–1.08; p < 0.001) were independently associated with bradyarrhythmias. Left ventricular dilatation (LVD) was independently associated with non-sustained VT (OR = 2.83; 95% CI, 1.01–7.96; p = 0.041).Conclusions:In medium-term follow-up of RTCs, ILR helped detect a high incidence of AE, most of which did not have clinical relevance. The PR interval and presence of long QTc were predictive of bradyarrhythmias, whereas LVD was predictive of non-sustained VT.