18 resultados para Monitor mode


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research was done to study the reproductive system of papaya hermaphrodite plant based on the histochemical nature of pollen grain, stigma receptivity, in vivo pollen grain germination and pollen:ovule ratio. In the histochemical analysis, pollen grains were stained by using Sudan IV and I2KI solution ; the stigma receptivity was assessed by alpha-naphthtyl acetate solution in closed and opened flowers. Pollen germination and pollen tube growing were examined in flower buds near anthesis with 0.1% aniline blue. To estimate the pollen:ovule ratio , anthers from each flower bud were dissected and all pollen grains were counted; ovules were dissected from ovaries and were counted under stereomicroscope. The results indicated that papaya pollen grains are of lipidic nature; the stigmas were receptive before the opening and until 48 hours after opening; the pollen grains germinated and emitted polinic tube before flower opening and the pollen:ovule ratio indicated the predominance of autogamous reproductive system. These results indicate that hermaphrodite papaya trees is preferentially of optional autogamous with cleistogamy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To compare the capacity of mammography, sonoelastography, B-mode ultrasonography and histological analysis to differentiate benign from malignant breast lesions. Materials and Methods A total of 12 histopathologically confirmed breast lesions were documented. The lesions were assessed by means of mammography, B-mode ultrasonography and sonoelastography, and histopathological analysis was utilized as a gold standard. Sensitivity and specificity were calculated. A receiver operating characteristic (ROC) curve was constructed to evaluate the diagnostic performance of the mentioned techniques. Results Sensitivity and specificity in the differentiation between benign and malignant lesions were respectively 100% and 50% for mammography, 100% and 71% for B-mode ultrasonography, and 67% and 83% for sonoelastography. The area under the ROC curve was calculated for the three imaging modalities and corresponded to 0.792 for mammography, 0.847 for B-mode ultrasonography, and 0.806 for sonoelastography. Conclusion Sonoelastography demonstrated higher specificity and lower sensitivity as compared with mammography and B-mode ultrasonography. On the other hand, B-mode ultrasonography had the largest area under the ROC curve. Sonoelastography has demonstrated to be a promising technique to detect and evaluate breast lesions, and could potentially reduce the number of unnecessary biopsies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.