76 resultados para Low cost analog test
Resumo:
Objective: to describe and evaluate the acceptance of a low-cost chest tube insertion porcine model in a medical education project in the southwest of Paraná, Brazil. Methods: we developed a low-cost and low technology porcine model for teaching chest tube insertion and used it in a teaching project. Medical trainees - students and residents - received theoretical instructions about the procedure and performed thoracic drainage in this porcine model. After performing the procedure, the participants filled a feedback questionnaire about the proposed experimental model. This study presents the model and analyzes the questionnaire responses. Results: seventy-nine medical trainees used and evaluated the model. The anatomical correlation between the porcine model and human anatomy was considered high and averaged 8.1±1.0 among trainees. All study participants approved the low-cost porcine model for chest tube insertion. Conclusion: the presented low-cost porcine model for chest tube insertion training was feasible and had good acceptability among trainees. This model has potential use as a teaching tool in medical education.
Resumo:
We describe a low-cost, high quality device capable of monitoring indirect activity by detecting touch-release events on a conducting surface, i.e., the animal's cage cover. In addition to the detecting sensor itself, the system includes an IBM PC interface for prompt data storage. The hardware/software design, while serving for other purposes, is used to record the circadian activity rhythm pattern of rats with time in an automated computerized fashion using minimal cost computer equipment (IBM PC XT). Once the sensor detects a touch-release action of the rat in the upper portion of the cage, the interface sends a command to the PC which records the time (hours-minutes-seconds) when the activity occurred. As a result, the computer builds up several files (one per detector/sensor) containing a time list of all recorded events. Data can be visualized in terms of actograms, indicating the number of detections per hour, and analyzed by mathematical tools such as Fast Fourier Transform (FFT) or cosinor. In order to demonstrate method validation, an experiment was conducted on 8 Wistar rats under 12/12-h light/dark cycle conditions (lights on at 7:00 a.m.). Results show a biological validation of the method since it detected the presence of circadian activity rhythm patterns in the behavior of the rats
Resumo:
In the present work the immune adherence hemagglutination test (IAHA) was standardized in a simplified procedure. This test showed good reproducibility, better than the classical mice serum neutralization test (SN). The tests showed high correlation degree: high titers in one test corresponded to high titers in the other one, and the same occured with low titers. The IAHA test is extremely simple, fast to perform, and of low cost when compared to tests such as SN or indirect immunofluorescense (IIF). It also proved to be useful in less sophisticated laboratories or even as a screening test for the titration of rabies antibodies.
Resumo:
Abstract:INTRODUCTION:The Montenegro skin test (MST) has good clinical applicability and low cost for the diagnosis of American tegumentary leishmaniasis (ATL). However, no studies have validated the reference value (5mm) typically used to discriminate positive and negative results. We investigated MST results and evaluated its performance using different cut-off points.METHODS:The results of laboratory tests for 4,256 patients with suspected ATL were analyzed, and 1,182 individuals were found to fulfill the established criteria. Two groups were formed. The positive cutaneous leishmaniasis (PCL) group included patients with skin lesions and positive direct search for parasites (DS) results. The negative cutaneous leishmaniasis (NCL) group included patients with skin lesions with evolution up to 2 months, negative DS results, and negative indirect immunofluorescence assay results who were residents of urban areas that were reported to be probable sites of infection at domiciles and peridomiciles.RESULTS:The PCL and NCL groups included 769 and 413 individuals, respectively. The mean ± standard deviation MST in the PCL group was 12.62 ± 5.91mm [95% confidence interval (CI): 12.20-13.04], and that in the NCL group was 1.43 ± 2.17mm (95% CI: 1.23-1.63). Receiver-operating characteristic curve analysis indicated 97.4% sensitivity and 93.9% specificity for a cut-off of 5mm and 95.8% sensitivity and 97.1% specificity for a cut-off of 6mm.CONCLUSIONS:Either 5mm or 6mm could be used as the cut-off value for diagnosing ATL, as both values had high sensitivity and specificity.
Resumo:
Abstract: INTRODUCTION: The treatment of individuals with active tuberculosis (TB) and the identification and treatment of latent tuberculosis infection (LTBI) contacts are the two most important strategies for the control of TB. The objective of this study was compare the performance of tuberculin skin testing (TST) with QuantiFERON-TB Gold In TUBE(r) in the diagnosis of LTBI in contacts of patients with active TB. METHODS: Cross-sectional analytical study with 60 contacts of patients with active pulmonary TB. A blood sample of each contact was taken for interferon-gamma release assay (IGRA) and subsequently performed the TST. A receiver operating characteristic curve was generated to assess the cutoff points and the sensitivity, predictive values, and accuracy were calculated. The agreement between IGRA and TST results was evaluated by Kappa coefficient. RESULTS: Here, 67.9% sensitivity, 84.4% specificity, 79.1% PPV, 75% NPV, and 76.7% accuracy were observed for the 5mm cutoff point. The prevalence of LTBI determined by TST and IGRA was 40% and 46.7%, respectively. CONCLUSIONS: Both QuantiFERON-TB Gold In TUBE(r) and TST showed good performance in LTBI diagnosis. The creation of specific diagnostic methods is necessary for the diagnosis of LTBI with higher sensitivity and specificity, preferably with low cost and not require a return visit for reading because with early treatment of latent forms can prevent active TB.
Resumo:
The aim of this work was to compare the performance of isotope-selective non-dispersive infrared spectrometry (IRIS) for the 13C-urea breath test with the combination of the 14C-urea breath test (14C-UBT), urease test and histologic examination for the diagnosis of H. pylori (HP) infection. Fifty-three duodenal ulcer patients were studied. All patients were submitted to gastroscopy to detect HP by the urease test, histologic examination and 14C-UBT. To be included in the study the results of the 3 tests had to be concordant. Within one month after admission to the study the patients were submitted to IRIS with breath samples collected before and 30 min after the ingestion of 75 mg 13C-urea dissolved in 200 ml of orange juice. The samples were mailed and analyzed 11.5 (4-21) days after collection. Data were analyzed statistically by the chi-square and Mann-Whitney test and by the Spearman correlation coefficient. Twenty-six patients were HP positive and 27 negative. There was 100% agreement between the IRIS results and the HP status determined by the other three methods. Using a cutoff value of delta-over-baseline (DOB) above 4.0 the IRIS showed a mean value of 19.38 (minimum = 4.2, maximum = 41.3, SD = 10.9) for HP-positive patients and a mean value of 0.88 (minimum = 0.10, maximum = 2.5, SD = 0.71) for negative patients. Using a cutoff value corresponding to 0.800% CO2/weight (kg), the 14C-UBT showed a mean value of 2.78 (minimum = 0.89, maximum = 5.22, SD = 1.18) in HP-positive patients. HP-negative patients showed a mean value of 0.37 (minimum = 0.13, maximum = 0.77, SD = 0.17). IRIS is a low-cost, easy to manage, highly sensitive and specific test for H. pylori detection. Storing and mailing the samples did not interfere with the performance of the test.
Resumo:
It is widely accepted that the classical constant-temperature hot-plate test is insensitive to cyclooxygenase inhibitors. In the current study, we developed a variant of the hot-plate test procedure (modified hot-plate (MHP) test) to measure inflammatory nociception in freely moving rats and mice. Following left and right hind paw stimulation with a phlogogen and vehicle, respectively, the animals were placed individually on a hot-plate surface at 51ºC and the withdrawal latency for each paw was determined simultaneously in measurements performed at 15, 60, 180, and 360 min post-challenge. Plantar stimulation of rats (250 and 500 µg/paw) and mice (125-500 µg/paw) with carrageenan led to a rapid hyperalgesic response of the ipsilateral paw that reached a plateau from 15 to 360 min after challenge. Pretreatment with indomethacin (4 mg/kg, ip) inhibited the phenomenon at all the times analyzed. Similarly, plantar stimulation of rats and mice with prostaglandin E2 (0.5 and 1 µg/paw) also resulted in rapid hyperalgesia which was first detected 15 min post-challenge. Finally, we observed that the MHP test was more sensitive than the classical Hargreaves' test, being able to detect about 4- and 10-fold lower doses of prostaglandin E2 and carrageenan, respectively. In conclusion, the MHP test is a simple and sensitive method for detecting peripheral hyperalgesia and analgesia in rats and mice. This test represents a low-cost alternative for the study of inflammatory pain in freely moving animals.
Resumo:
The determination of anti-HBs as a screening test before vaccination has been advisable in order to encounter immune individuals that don't need to receive vaccine protection. A case-report is presented and three other cases are reviewed from the literature. Anti-HBs was positive in these health-care personnels that developped typical acute B hepatitis. Different subtyping involving the d/y determinants were found in the first case, but false-positive anti-HBs even with high titres, determined by RIA, were found in the other cases. Concomitant determination of anti-HBc or absence of screening tests seem to be more reasonable policies until a low-cost and risk-free vaccine is produced.
Resumo:
In search of an efficient but simple, low cost procedure for the serodiagnosis of Toxoplasmosis, especially suited for routine laboratories facing technical and budget limitations as in less developed countries, the diagnostic capability of Hematoxo® , an hemagglutination test for toxoplasmosis, was evaluated in relation to a battery of tests including IgG- and IgM-immunofluorescence tests, hemagglutination and an IgM-capture enzymatic assay. Detecting a little as 5 I.U. of IgG antitoxoplasma antibodies, Hematoxo® showed a straight agreement as to reactivity and non-reactivity for the 443 non-reactive and the 387 reactive serum samples, included in this study. In 23 cases presenting a serological pattern of acute toxoplasmosis and showing IgM antibodies, Hematoxo® could detect IgM antibodies in 18, indicated by negativation or a significant decrease in titers as a result of treating samples with 2-mercapto-ethanol. However, a neat increase in sensitivity for IgM specific antibodies could be achieved by previously removing IgG from the sample, as demonstrated in a series of acute toxoplasmosis sera. A simple procedure was developed for this purpose, by reconstituting a lyophilized suspension of Protein A - rich Staphylococcus with the lowest serum dilution to be tested. Of low cost and easy to perform, Hematoxo® affords not only a practical qualitative procedure for screening reactors and non-reactors, as in prenatal services, but also quantitative assays that permit to titrate antibodies as well as to identify IgM antibodies.
Resumo:
A dot-ELISA was developed for the detection of antibodies in CSF in the immunologic diagnosis of human neurocysticercosis, using antigen extracts of the membrane and scolex of Cysticercus cellulosae (M+S-Cc) and, alternately, membrane (M) and vesicular fluid (VF) of Cysticercus longicollis (Cl) covalently bound to a new solid phase consisting of polyester fabric treated with N-methylol-acrylamide resin (dot-RT). The test was performed at room temperature, with reduced incubation times and with no need for special care in the manipulation of the support. The sensitivity rates obtained were 95.1% for antigen Cc and 97.6% for antigen Cl. Specificity was 90.6% when Cc was used, and 96.9% and 100% when M-Cl and VF-Cl were used, respectively. No significant differences in titer were observed between tests carried out with homologous and heterologous antigens. The low cost and easy execution of the dot-RT test using antigen extracts of Cysticercus longicollis indicate the test for use in the immunodiagnosis of human neurocysticercosis.
Resumo:
INTRODUCTION: Leptospirosis is often mistaken for other acute febrile illnesses because of its nonspecific presentation. Bacteriologic, serologic, and molecular methods have several limitations for early diagnosis: technical complexity, low availability, low sensitivity in early disease, or high cost. This study aimed to validate a case definition, based on simple clinical and laboratory tests, that is intended for bedside diagnosis of leptospirosis among hospitalized patients. METHODS: Adult patients, admitted to two reference hospitals in Recife, Brazil, with a febrile illness of less than 21 days and with a clinical suspicion of leptospirosis, were included to test a case definition comprising ten clinical and laboratory criteria. Leptospirosis was confirmed or excluded by a composite reference standard (microscopic agglutination test, ELISA, and blood culture). Test properties were determined for each cutoff number of the criteria from the case definition. RESULTS: Ninety seven patients were included; 75 had confirmed leptospirosis and 22 did not. Mean number of criteria from the case definition that were fulfilled was 7.8±1.2 for confirmed leptospirosis and 5.9±1.5 for non-leptospirosis patients (p<0.0001). Best sensitivity (85.3%) and specificity (68.2%) combination was found with a cutoff of 7 or more criteria, reaching positive and negative predictive values of 90.1% and 57.7%, respectively; accuracy was 81.4%. CONCLUSIONS: The case definition, for a cutoff of at least 7 criteria, reached average sensitivity and specificity, but with a high positive predictive value. Its simplicity and low cost make it useful for rapid bedside leptospirosis diagnosis in Brazilian hospitalized patients with acute severe febrile disease.
Resumo:
OBJECTIVES: To determine the efficacy of a simple, short-term and low-cost eradication treatment for Helicobacter pylori (H. pylori) using omeprazole, tetracycline, and furazolidone in a Brazilian peptic ulcer population, divided into 2 subgroups: untreated and previously treated for the infection. PATIENTS AND METHODS: Patients with peptic ulcer disease diagnosed by endoscopic examination and infected by H. pylori diagnosed by the rapid urease test (RUT) and histological examination, untreated and previously unsuccessfully treated by macrolides and nitroimidazole, were medicated with omeprazole 20 mg daily dose and tetracycline 500 mg and furazolidone 200 mg given 3 times a day for 7 days. Another endoscopy or a breath test was performed 12 weeks after the end of treatment. Patients were considered cured of the infection if a RUT and histologic examination proved negative or a breath test was negative for the bacterium. RESULTS: Sixty-four patients were included in the study. The women were the predominant sex (58%); the mean age was 46 years. Thirty-three percent of the patients were tobacco users, and duodenal ulcer was identified in 80% of patients. For the 59 patients that underwent follow-up examinations, eradication was verified in 44 (75%). The eradication rate for the intention-to-treat group was 69%. The incidence of severe adverse effects was 15%. CONCLUSION: The treatment provides good efficacy for H. pylori eradication in patients who were previously treated without success, but it causes severe adverse effects that prevented adequate use of the medications in 15% of the patients.
Resumo:
Studying the application of those methods of microanalysis which avoid costly instalations and atempting to combine high precision with low cost, the author recomends a new method consisting of the following : a) exposure of a surface of 530.66 mm2 of Zn to the action of the acid. b) instalation of 3 series of HgBr2 paper in test tubes with an internal diameter of respectively 3,5 and 9 mm. c - mouting between two slides, covering the margins (with parafin etc.) with parafin in order to conserve the results of the determination without change due to the action of light or moisture. d) the results can be compared at a level of 0.00001 mgr. A203 or 0.000007575 mgr. As.
Resumo:
The aim of this study was to evaluate the indirect immunoperoxidase virus neutralization (IPVN) and mouse neutralization test (MNT) to detect antibodies against rabies virus from vaccinated dogs and cattle. The IPVN was set up for the ability to measure 0.5 International Units/ml (IU) of antibody required by the World Health Organization and the Office International des Epizooties as the minimum response for proof of rabies immunization. IPVN was developed and standardized in chicken embryo related (CER) cell line when 141 dog and 110 cattle sera were applied by serial five-fold dilutions (1:5, 1:25, 1:125) as well as the positive and negative reference controls, all added in four adjacent wells, of 96-well microplates. A 50 µl amount of CVS32 strain dilution containing 50-200 TCID50/ml was mixed to each serum dilution, and after 90 min 50 µl of 3 x 10(5) cells/mlcell suspension added to each well. After five days of incubation, the monolayers were fixed and the IPVN test performed. The correlation coefficient between the MNT and IPVN performed in CER cells was r = 0.9949 for dog sera (n = 100) and r = 0.9307 for cattle sera (n = 99), as well as good specificity (94.7%), sensitivity (87.5%), and agreement (96.6%) were also obtained. IPVN technique can adequately identify vaccinated and unvaccinated animals, even from low-responding vaccinated animals, with the advantage of low cost and faster then MNT standard test.
Resumo:
A study was carried out to compare the performance of a commercial method (MGIT) and four inexpensive drug susceptibility methods: nitrate reductase assay (NRA), microscopic observation drug susceptibility (MODS) assay, MTT test, and broth microdilution method (BMM). A total of 64 clinical isolates of Mycobacterium tuberculosis were studied. The Lowenstein-Jensen proportion method (PM) was used as gold standard. MGIT, NRA, MODS, and MTT results were available on an average of less than 10 days, whereas BMM results could be reported in about 20 days. Most of the evaluated tests showed excellent performance for isoniazid and rifampicin, with sensitivity and specificity values > 90%. With most of the assays, sensitivity for ethambutol was low (62-87%) whereas for streptomycin, sensitivity values ranged from 84 to 100%; NRA-discrepancies were associated with cultures with a low proportion of EMB-resistant organisms while most discrepancies with quantitative tests (MMT and BMM) were seen with isolates whose minimal inhibitory concentrations fell close the cutoff. MGIT is reliable but still expensive. NRA is the most inexpensive and easiest method to perform without changing the organization of the routine PM laboratory performance. While MODS, MTT, and BMM, have the disadvantage from the point of view of biosafety, they offer the possibility of detecting partial resistant strains. This study shows a very good level of agreement of the four low-cost methods compared to the PM for rapid detection of isoniazid, rifampicin and streptomycin resistance (Kappa values > 0.8); more standardization is needed for ethambutol.