129 resultados para Leptin antibody


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An IgG2a subclass monoclonal antibody, C6G9, was obtained by immunization of BALB/c mice with Schistosoma mansoni egg antigens. With this monoclonal antibody, it was possible to identify a schistosomular antigen with a molecular weight of 46 kilodaltons (KDa), and its expression being evaluated by means of indirect immunofluorescence. The antigen persisted in the integument of the developing schistosomulum, for at least 96 hours post-transformation. The monoclonal antibody also reacted with the cercaria surface, but not with that of adult worm. The C6G9 was also able to mediate significant levels of cytotoxicity in the presence of complement for newly transformed schistosomula.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and specific Capture Sandwich ELISA (CSE) was developed using polyclonal purified rabbit antibodies against three different axenic strains of Entamoeba histolytica: CSP from Brazil and HM1 - IMSS from Mexico, for the detection of coproantigens in fecal samples. Immunoglobulin G (IgG) againstis E. histolytica was isolated from rabbits immunized with throphozoites whole extract in two stages: affinity chromatography in a column containing E. histolytica antigens bound to Sepharose 4B was followed by another chromatography in Sepharose antibodies 4B-Protein A. A Capture Sandwich ELISA using purified antibodies was able to detect 70ng of amebae protein, showing a sensitivity of 93% and specificity of 94%. The combination of microscopic examination and CSE gave a concordance and discordance of 93.25% and 6.75%, respectively. It was concluded that CSE is highly specific for the detection of coproantigens of E. histolytica in feces of infected patients, is quicker to perform, easier and more sensitive than microscopic examination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neisseria meningitidis are gram-negative diplococci responsible for cases of meningococcal disease all over the world. The epidemic potential of N. meningitidis serogroup B and C is clearly a function of their serotype antigens more than of their capsular polysaccharides. Until recently, hiperimmune sera were used to detect typing antigens on the bacteria. The advent of monoclonal antibodies (MAbs) offered the opportunity to eliminate many of the cross-reactions and have improved the accuracy and reproducibility of meningococcal serotyping. We have produced a MAb to the outer membrane protein of the already existent serotype 17 that have been detected by the use of hiperimmune rabbit sera. The prevalence of this serotype epitope is low in the Brazilian strains. By using the MAb 17 we could not decrease the percentage of nontypeable serogroup C strains. However, there were a decreasing in nontypeable strains to 13% into serogroup B strains and to 25% into the other serogroups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anti-Toxocara antibody production and persistence were studied in experimental infections of BALB/c mice, according to three different schedules: Group I (GI) - 25 mice infected with 200 T. canis eggs in a single dose; Group II (GII) 25 mice infected with 150 T. canis eggs given in three occasions, 50 in the 1st, 50 in the 5th and 50 in the 8th days; Group III (GIII) - 25 mice also infected with 150 T. canis eggs, in three 50 eggs portions given in the 1st, 14th and 28th days. A 15 mice control group (GIV) was maintained without infection. In the 30th, 50th, 60th, 75th, 105th and 180th post-infection days three mice of the GI, GII and GIII groups and two mice of the control group had been sacrificed and exsanguinated for sera obtention. In the 360th day the remainder mice of the four groups were, in the same way, killed and processed. The obtained sera were searched for the presence of anti-Toxocara antibodies by an ELISA technique, using T. canis larvae excretion-secretion antigen. In the GI and GII, but not in the GIII, anti-Toxocara antibodies had been found, at least, up to the 180th post-infection day. The GIII only showed anti-Toxocara antibodies, at significant level, in the 30th post-infection day.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amebiasis continues to be of epidemiological importance in underdeveloped countries. Clinical diagnosis and epidemiological setting in a region are based on the fecal microscopic identification of cysts or trophozoites. This procedure requires well trained personnel, is laborious, of low sensitivity and frequently yields false-positives results. The present study was designed to develop an immuno-enzymatic fecal 96 kDa antigen capture test (COPROELISA-Eh) more sensitive and specific than microscopic diagnosis of amebiasis. Triplicates of 177 stool samples processed by the formol-ether concentration method, were defined as positive or negative by three experienced microscopic observers. Another aliquot was submitted to the antigen capture test by a monoclonal antibody against a specific membrane antigen of pathogenic strains of Entamoeba histolytica. Optical densities were interpreted as positive when they exceeded the mean value of negative samples plus two standard deviations. COPROELISA-Eh showed a 94.4% sensitivity, 98.3% specificity, 96.2% positive predictive value and 97.6% negative predictive value for the detection of E. histolytica in feces. COPROELISA-Eh is more sensitive and specific than microscopic examination, does not require specially trained personnel and allows the simultaneous processing of a large number of samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three months after a mass vaccination campaign (coverage: 100%) against measles a random seroepidemiological survey was carried out in students aged 1 to 19 years old in the Municipality of Niterói, State of Rio de Janeiro. Blood samples were tested for measles antibodies by enzyme immunosorbent assay (EIA) and negative cases were tested again using hemagglutination inhibition (HI) and plaque reduction neutralization (PRN). Of the 798 samples tested by EIA, 718 (90.2%) were positive for measles antibodies. PRN test was more sensitive than EIA and HI in detecting measles specific antibodies. The total antibody prevalence increased from 90.2% to 93.2% when HI was employed in EIA negative specimens and to 98.9% when PRN was used. After the mass vaccination campaign a marked decrease in measles incidence was observed in the municipality studied, showing the effectiveness of the strategy used for measles control in developing countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antibodies to a number of parasite antigens are found in schistosomiasis patients, and antibodies to early developmental stages were demonstrated to be efficient immunologic markers for the diagnosis of schistosomiasis. In the present study, decay patterns of IgM and IgG antibodies against cercariae and schistosomula were investigated, in comparison to antibodies against worms and eggs in schistosomiasis patients after chemotherapy, for an investigation of seroepidemiologic aspects. Data obtained in the study of 359 serum samples from patients with Schistosoma mansoni infection, noninfected individuals, and patients followed-up for a period of 12 to 15 months after treatment provided the basis to postulate a general pattern for the kinetics of antibody decay. Before treatment, the antibody pattern was represented by a unimodal curve, which shifted to a bimodal curve after treatment, and ended with a unimodal curve similar to that for the noninfected group. Different types of antibodies were classified into four categories according to their decay features, and anti-schistosomulum IgM was classified into the moderate-decay caterogy, whereas other antibodies to early parasite stages were classified into the slow-decay category. The present methodology permits the identification of the most suitable antibodies to be detected in field control programs for schistosomiasis or other parasitoses

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The persistence, in some subjects, of specific IgM antibodies to Toxoplasma gondii for several months after the acute phase of infection has complicated the interpretation of serological test results for toxoplasmosis. Several reports have emphasized the value of the detection of Toxoplasma-specific IgA antibodies for the diagnosis of acute toxoplasmosis. In this article, we report the follow-up profiles of Toxoplasma-specific IgM and IgA antibodies in serum samples obtained from 12 patients at various intervals after the onset of the clinical manifestations of infection. IgM antibodies were detected by the indirect immunofluorescence (IIF) test, antibody capture enzyme-linked immunosorbent assay (cELISA) and enzyme-mediated chemilluminescent technique (CmL). IgA antibodies were quantified by the direct ELISA (dELISA) and cELISA procedures. As defined by the manufacturer of the cELISA test for IgA used, most patients with acute toxoplasmosis have antibody levels > 40 arbritary units per ml (AU/ml). At values > 40 AU/ml, the cELISA for IgA detected significant antibody levels for a shorter time than the other techniques used for IgM and IgA detection. However, IgA levels £ 40 AU/ml do not exclude the possibility of acute toxoplasmosis since such levels can be reached very soon after infection with T. gondii. The results obtained in the present study show that the serological diagnosis of acute toxoplasmosis may not be such an easy task. Our data suggest that use of the IgA-cELISA concomitantly with IgM antibody screening could permit, in some circumstances, a more efficient diagnosis of acute acquired toxoplasmosis

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recognition profile of the tissue cysts antigens by IgG antibodies was studied during acute and chronic human toxoplasmic infection. Thus the IgG response against Toxoplasma gondii was investigated by immunoblotting in two patients accidentally infected with the RH strain as well as in group of naturally infected patients at acute and chronic phase. There was an overall coincidence of molecular mass among antigens of tachyzoites and tissue cysts recognized by these sera, however, they appear not to be the same molecules. The response against tissue cysts starts early during acute infection, and the reactivity of antibodies is strong against a wide range of antigens. Six bands (between 82 and 151 kDa) were exclusively recognized by chronic phase sera but only the 132 kDa band was positive in more than 50% of the sera analysed. A mixture of these antigens could be used to discriminate between the two infection phases. The most important antigens recognized by the acute and the chronic phase sera were 4 clusters in the ranges 20-24 kDa, 34-39 kDa, 58-80 kDa and 105-130 kDa as well as two additional antigens of 18 and 29 kDa. Both accidentally infected patients and some of the naturally infected patients showed a weak specific response against tissue cyst antigens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationship between the IgM antibody response, antigenic load as well as the clinical improvement after chemotherapy was studied in order to obtain useful data for the early diagnosis and monitoring leprosy. A level of 82% (94/115) agreement was obtained between IgM UMELISA HANSEN and slitskin smear examination. Discrepant results were observed in 16 patients who showed positive IgM response despite negative by the skin smear examination. In these patients, the IgM response was seen to be associated to the early signal for bacilli recurrence in the skin. In one of these patients the presence of bacilli was demonstrated in the skin, two months after IgM antibodies being detected by UMELISA HANSEN. Also in one of the treated patients positive by both diagnostic techniques, a remarkable decrease in the IgM antibody levels was seen, correlating with a significant clinical improvement. Moreover it was found a direct relationship between the IgM antibody response and bacterial antigenic load, regardless the time elapsed in the disease's evolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most practicable assay for measurement of measles IgG (mIgG) in large numbers of sera is an enzyme immunoassay (EIA). To assess how EIA results would agree with those by the gold standard method of plaque reduction neutralization (PRN) we compared the results from the two methods in 43 pairs of maternal and umbilical cord sera, and sera from the corresponding infants when aged 11 - 14 months. In maternal-cord sera, the differences between mean antibody levels by EIA or PRN were not statistically significant, though in individual sera, differences could be large. However, agreement was less good for infants sera, in which levels of mIgG were very low. The conclusions of a study of transplacental transport of mIgG would not be affected by the use of either technique. When studying waning immunity in infants, PRN should be the method of choice, while results from studies using EIA should be interpreted with caution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Toxocariasis is caused by infection of man by Toxocara canis and Toxocara cati larvae, the common roundworm of dogs and cats. Because larvae are difficult to detect in tissues, diagnosis is mostly based on serology. Non specific reactions are observed mainly due to cross-reactivity with Ascaris sp antigens. This investigation aimed at developing and evaluating an indirect antibody competition ELISA (IACE) employing a specific rabbit IgG anti-Toxocara canis excretory-secretory antigens as the competition antibody, in order to improve indirect ELISA specificity performed for toxocariasis diagnosis. For that, the rabbit IgG was previously absorbed by Ascaris suum adult antigens. Sensitivity and specificity of IACE were first evaluated in 28 serum samples of mice experimentally infected with T. canis embryonated eggs. Adopting cut-off value established in this population before infection, sensitivity and specificity were 100% after 20 days post-inoculation. For human population IACE was evaluated using sera from 440 patients with clinical signs of toxocariasis and the cut-off value was established with 60 serum samples from apparently healthy individuals. Using as reference test the indirect ELISA performed by Adolfo Lutz Institute, sensitivity was 60.2%, specificity was 98% and concordance was 77.3%. Repeatability of IACE was evaluated by the inter-reactions variation coefficient (2.4%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the detection of specific IgA antibodies and the determination of IgG avidity in sequential serum samples from a patient exhibiting significant levels of Toxoplasma-specific IgM antibodies for seven years after the onset of the clinical symptoms of toxoplasmosis. IgM antibodies were detected by an indirect immunofluorescence test and by three commercial enzyme-linked immunosorbent assays (ELISA). Anti-T. gondii IgA was quantified by the a-capture ELISA technique using a commercial kit. As defined by the manufacturer of the IgA ELISA test used, most patients with acute toxoplasmosis have antibody levels > 40 arbitrary units per ml (AU/mL). At this cut-off level, the patient still had a positive ELISA result (45 AU/mL) in a serum sample taken one year after the beginning of clinical manifestations. The IgG avidity-ELISA test was performed with the Falcon assay screening test (F.A.S.T.®) - ELISA system. Avidity indices compatible with a recent Toxoplasma infection were found only in serum samples taken during the first 5 months after the onset of the clinical symptoms of toxoplasmosis. These results show that the interpretation of positive IgM results as indicative of recently acquired toxoplasmosis requires additional laboratory confirmation either by other tests or by the demonstration of a significant rise in the antibody titers in sequential serum samples.