42 resultados para Generic Core Scales
Resumo:
This study was undertaken to evaluate an enzyme immunoassay (EIA) for hepatitis C virus antibody detection (anti-HCV), using just one antigen. Anti-HCV EIA was designed to detect anti-HCV IgG using on the solid-phase a recombinant C22 antigen localized at the N-terminal end of the core region of HCV genome, produced by BioMérieux. The serum samples diluted in phosphate buffer saline were added to wells coated with the C22, and incubated. After washings, the wells were loaded with conjugated anti-IgG, and read in a microtiter plate reader (492 nm). Serum samples of 145 patients were divided in two groups: a control group of 39 patients with non-C hepatitis (10 acute hepatitis A, 10 acute hepatitis B, 9 chronic hepatitis B, and 10 autoimmune hepatitis) and a study group consisting of 106 patients with chronic HCV hepatitis. In the study group all patients had anti-HCV detected by a commercially available EIA (Abbott®), specific for HCV structural and nonstructural polypeptides, alanine aminotransferase elevation or positive serum HCV-RNA detected by nested-PCR. They also had a liver biopsy compatible with chronic hepatitis. The test was positive in 101 of the 106 (95%) sera from patients in the study group and negative in 38 of the 39 (97%) sera from those in the control group, showing an accuracy of 96%. According to these results, our EIA could be used to detect anti-HCV in the serum of patients infected with hepatitis C virus.
Resumo:
The prevalence of antibodies to hepatitis B core antigen in 552 prime blood donors was of 9.4%. The majority (71.2%) has antibodies to hepatitis B surface antigen. The hepatitis B surface antigen was present in 0.7%, all of them antibodies to hepatitis B core antigen positive.
Resumo:
Humoral and cellular immune responses are currently induced against hepatitis C virus (HCV) core following vaccination with core-encoding plasmids. However, the anti-core antibody response is frequently weak or transient. In this paper, we evaluated the effect of different additives and DNA-protein combinations on the anti-core antibody response. BALB/c mice were intramuscularly injected with an expression plasmid (pIDKCo), encoding a C-terminal truncated variant of the HCV core protein, alone or combined with CaCl2, PEG 6000, Freund's adjuvant, sonicated calf thymus DNA and a recombinant core protein (Co.120). Mixture of pIDKCo with PEG 6000 and Freund's adjuvant accelerated the development of the anti-core Ab response. Combination with PEG 6000 also induced a bias to IgG2a subclass predominance among anti-core antibodies. The kinetics, IgG2a/IgG1 ratio and epitope specificity of the anti-core antibody response elicited by Co.120 alone or combined with pIDKCo was different regarding that induced by the pIDKCo alone. Our data indicate that the antibody response induced following DNA immunization can be modified by formulation strategies.
Resumo:
To increase blood safety Brazil introduced screening for anti-HBc among blood donors in 1993. There was a decrease in the hepatitis B virus (HBV) transmission, but this measure identified a great number of HBsAg-negative, anti-HBc-positive donors. Surveillance policy determines that contacts of HBV carriers should be screened to HBV markers, but there is no recommendation about how to guide contacts of HBsAg-negative, anti-HBc-positive donors. Aiming to evaluate whether the contacts of this group are at greater risk for HBV infection, a cross-sectional study was performed to compare prevalence of HBV infection between contacts of HBsAg-positive blood donors (group I) and contacts of HBsAg-negative, anti-HBc-positive donors (group II). Contacts were submitted to a questionnaire and blood tests for HBV markers. In group I (n = 143), 53 (37.1%) were anti-HBc-positive and 11 (7.7%) were HBsAg-positive. In group II (n = 111), there were 9 and 0.9%, respectively. HBV exposure was associated with group I, sexual activity, blood transfusion, being one of the donor's parents, and living for more than ten years with the donor. Regarding the families as sample units, it was more common to find at least one member with HBV markers (p < 0.05) among the families of group I compared to group II. Contacts of HBsAg-negative, anti-HBc-positive individuals presented a much lower risk of having already been exposed to HBV and there is no need to screen them for HBV in low to moderate prevalence populations.
Resumo:
The distribution of Lutzomyia longipalpis is heterogeneous with a pattern of high abundance areas (HAAs) embedded in a matrix of low abundance areas (LAAs). The objective of this study was to describe the variability in the abundance of Lu. longipalpis at two different spatial levels and to analyse the relationship between the abundance and multiple environmental variables. Of the environmental variables analysed in each household, the condition that best explained the differences in vector abundance between HAA-LAA was the variable "land_grass", with greater average values in the peridomestic environments within the LAA, and the variables "#sp tree", "#pots" and "dist_water" that were higher in the HAA. Of the environmental variables analysed in the patches, the variable "unpaved_streets" was higher in the LAAs and the variable "prop_inf_dogs" was higher in the HAAs. An understanding of the main environmental variables that influence the vector distribution could contribute to the development of strategies for the prevention and control of visceral leishmaniasis (VL). This is the first work in which environmental variables are analysed at the micro-scale in urban areas at the southern edge of the current range of Lu. longipalpis. Our results represent a significant contribution to the understanding of the abundance of the vector in the peridomestic habitats of the region.
Resumo:
Este estudo teve por objetivos traduzir e adaptar o Newcastle Satisfaction with Nursing Scales para a cultura brasileira, bem como verificar seu uso prático. O instrumento contém duas escalas e tem como objetivo avaliar as experiências vivenciadas pelo paciente e a satisfação com o cuidado de enfermagem. Para o procedimento metodológico de adaptação cultural foram seguidas as etapas de tradução, síntese, retro-tradução, avaliação pelo comitê de especialistas e pré-teste. O processo de tradução e adaptação cultural foi considerado apropriado. A avaliação pelo comitê de especialistas resultou em modificações gramaticais simples para a maioria dos itens e, no pré-teste, participaram 40 sujeitos. A versão brasileira do Newcastle Satisfaction with Nursing Scales demonstrou adequada validade de conteúdo e facilidade de compreensão pelos sujeitos. Contudo, este é um estudo que antecede o processo de avaliação das propriedades psicométricas do instrumento, cujos resultados serão apresentados em publicação posterior.
Resumo:
AbstractOBJECTIVECorrelating two unidimensional scales for measurement of self-reported pain intensity for elderly and identifying a preference for one of the scales.METHODA study conducted with 101 elderly people living in Nursing Home who reported any pain and reached ( 13 the scores on the Mini-Mental State Examination. A Numeric Rating Scale - (NRS) of 11 points and a Verbal Descriptor Scale (VDS) of five points were compared in three evaluations: overall, at rest and during movement.RESULTSWomen were more representative (61.4%) and the average age was 77.0±9.1 years. NRS was completed by 94.8% of the elderly while VDS by 100%. The association between the mean scores of NRS with the categories of VDS was significant, indicating convergent validity and a similar metric between the scales.CONCLUSIONPain measurements among institutionalized elderly can be made by NRS and VDS; however, the preferred scale for the elderly was the VDS, regardless of gender.
Resumo:
A list of species of tribe Aedini from Middle and South American, south of the United States, with their current generic combinations is provided. Its purpose is to enable entomologists, public health personnel and mosquito control workers to more quickly become familiar with recent formal taxonomic changes within the tribe.
Resumo:
Este artigo aborda a necessidade de adoção de padrões de descrição de recursos de informação eletrônica, particularmente, no âmbito da Embrapa Informática Agropecuária. O Rural Mídia foi desenvolvido utilizando o modelo Dublin Core (DC) para descrição de seu acervo, acrescido de pequenas adaptações introduzidas diante da necessidade de adequar-se a especificidades meramente institucionais. Este modelo de metadados baseado no Dublin Core, adaptado para o Banco de Imagem, possui características que endossam a sua adoção, como a simplicidade na descrição dos recursos, entendimento semântico universal (dos elementos), escopo internacional e extensibilidade (o que permite sua adaptação às necessidades adicionais de descrição).
Resumo:
This study aimed to establish relationships between maize yield and rainfall on different temporal and spatial scales, in order to provide a basis for crop monitoring and modelling. A 16-year series of maize yield and daily rainfall from 11 municipalities and micro-regions of Rio Grande do Sul State was used. Correlation and regression analyses were used to determine associations between crop yield and rainfall for the entire crop cycle, from tasseling to 30 days after, and from 5 days before tasseling to 40 days after. Close relationships between maize yield and rainfall were found, particularly during the reproductive period (45-day period comprising the flowering and grain filling). Relationships were closer on a regional scale than at smaller scales. Implications of the crop-rainfall relationships for crop modelling are discussed.
Resumo:
Com o objetivo de avaliar o desempenho das agulhas de calibres 14 e 12 na obtenção de "core biopsies" da mama sob controle estereotáxico, os autores compararam biópsias de lesões mamárias impalpáveis obtidas com agulhas desses calibres quanto ao tamanho dos fragmentos e freqüência dos tipos de lesões diagnosticadas. De um total de 1.009 biópsias, os autores analisaram 900 obtidas por agulhas 14 e 109 obtidas por agulhas 12, para análise da freqüência das lesões. Os tamanhos dos fragmentos foram analisados nos 700 primeiros casos para os espécimes obtidos por agulhas 14. A utilização de agulhas 12 resultou em maior tamanho dos fragmentos (p < 0,001), ausência de material insatisfatório, redução na proporção das lesões benignas não-neoplásicas (p = 0,03) e aumento na freqüência de carcinomas (p < 0,001), tanto in situ como invasivos. Tais achados podem refletir aumento da acurácia do diagnóstico, em virtude da maior quantidade de material e/ou melhor seleção radiológica das biópsias obtidas por agulhas 12, pela utilização coincidente da mamografia digital em campo limitado (estereotaxia digital).
Resumo:
OBJETIVO: Mostrar a eficácia do método para evitar biópsias excisionais, verificar suas dificuldades técnicas, definir entre seguimento e biópsia excisional nos nódulos categoria IV do BI-RADS™ e agilizar o procedimento cirúrgico nos casos de nódulos altamente suspeitos de malignidade (categoria V). MATERIAIS E MÉTODOS: As pacientes foram submetidas a exame clínico de rotina, mamografia e ultra-som. A "core" foi feita com pistola automática e agulha número 14, e foram colhidas de quatro a oito amostras. RESULTADOS: Das 100 lesões estudadas, 47 foram submetidas à cirurgia, além da "core", e diagnosticaram-se 34 carcinomas (34,0%). Das 23 lesões classificadas como categoria III, identificou-se apenas um carcinoma (4,34%); das 43 classificadas como categoria IV, sete (16,28%); e das 34 classificadas como categoria V, 26 (76,47%). Evitou-se a biópsia excisional em 53 casos (53,0%). Identificou-se dificuldade no método da "core" em sete casos (7,0%), devido a material insuficiente, risco para malignidade envolvendo lesões esclerosantes complexas e discordância entre imagem e histologia. As 33 lesões com resultados de malignidade à punção biópsia por agulha grossa foram confirmadas após a biópsia cirúrgica. Em um caso o diagnóstico pela "core" foi de hiperplasia ductal atípica e após a biópsia cirúrgica da peça diagnosticou-se carcinoma, correspondendo a um resultado falso-negativo. Não houve nenhum resultado falso-positivo.
Resumo:
Ultrasound-guided core-needle biopsy has high sensitivity in the diagnosis of breast cancer. The present study is aimed at detailing the main steps of such procedure, including indications, advantages, limitations, follow-up and description of the technique, besides presenting a checklist including the critical steps required for an appropriate practice of the technique. In the recent years, an increasing number of patients have required breast biopsy, indicating the necessity of a proportional increase in the number of skilled professionals to carry out the procedures and histological diagnoses. A multidisciplinary approach involving the tripod clinical practice-radiology-pathology is responsible for the highest rate of accuracy of the technique and must always be adopted.
Resumo:
Abstract Objective: To determine the rates of diagnostic underestimation at stereotactic percutaneous core needle biopsies (CNB) and vacuum-assisted biopsies (VABB) of nonpalpable breast lesions, with histopathological results of atypical ductal hyperplasia (ADH) or ductal carcinoma in situ (DCIS) subsequently submitted to surgical excision. As a secondary objective, the frequency of ADH and DCIS was determined for the cases submitted to biopsy. Materials and Methods: Retrospective review of 40 cases with diagnosis of ADH or DCIS on the basis of biopsies performed between February 2011 and July 2013, subsequently submitted to surgery, whose histopathological reports were available in the internal information system. Biopsy results were compared with those observed at surgery and the underestimation rate was calculated by means of specific mathematical equations. Results: The underestimation rate at CNB was 50% for ADH and 28.57% for DCIS, and at VABB it was 25% for ADH and 14.28% for DCIS. ADH represented 10.25% of all cases undergoing biopsy, whereas DCIS accounted for 23.91%. Conclusion: The diagnostic underestimation rate at CNB is two times the rate at VABB. Certainty that the target has been achieved is not the sole determining factor for a reliable diagnosis. Removal of more than 50% of the target lesion should further reduce the risk of underestimation.