21 resultados para Gemstone Team ELECTRODE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of a carbon paste electrode (CPE) modified with SBA-15 nanostructured silica organofunctionalised with 2-benzothiazolethiol for determination of Cu(II) ions in sugar cane spirit (cachaça) is described, based on differential pulse anodic stripping voltammetry (DPASV) procedure. The Cu(II) oxidation peak was observed at 0.03 V (vs. SCE) in phosphate solution (pH 3.0). The results were obtained using optimised conditions such as 100 mV pulse amplitude, 3 min accumulation time, 25 mV s-1 scan rate in phosphate solution pH 3.0, resulting in a linear dynamic range from 8.0 x 10-7 to 1.0 x 10-5 mol L-1 Cu(II) and a limit of detection 2.0 x10-7 mol L-1. Cu(II) spiked in a cachaça sample was determined with 102.5 % mean recovery at mmol L-1 level. Interference from other metallic cations present in the sample was avoided by the standard addition procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrode kinetics and complex formation of Zn(II) using doxycycline, chlortetracycline, oxytetracycline, tetracycline, minocycline, amoxicillin, chloramphenicol and cephaloglycin were reported at pH = 7.30 ± 0.01 in = 1.0 molL-1 NaClO4 used as supporting electrolyte at 25.0°C. Kinetic parameters viz. transfer coefficient (α), degree of irreversibility (λ) and rate constant (k) were determined. The study showed that 'Transition state' behaves between reactant (O) and product (R) response to applied potential. The stability constants varied from 2.14 to 10.31 showing that these drugs or their complexes could be used against Zn toxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As variações nos parâmetros hematológicos são utilizadas com intuito de avaliar o grau de treinamento ou estado clínico do animal. A avaliação hematológica de eqüinos em repouso tem sido objeto de estudo, a fim de estabelecer uma relação com treinamento ou capacidade atlética. Objetivou-se avaliar o perfil hematológico de eqüinos submetidos à prova de Team Penning, correlacionando o sexo e freqüência da atividade física. Mediante punção da veia jugular externa coletaram-se dois mL de sangue de 29 eqüinos, 18 machos e 11 fêmeas, em repouso (Momento I) e após o exercício (Momento II). As amostras de sangue foram processadas em analisador hematológico automático veterinário (ABC VET - Horiba ABX Diagnostics). Os animais foram divididos em Grupos A, B, C e D, de acordo com o número de participações na prova. Observou-se que os valores de volume globular, hemoglobina, hemácias, leucócitos, neutrófilos em bastonetes e segmentados, e monócitos aumentaram após o exercício físico, ao contrário do número de linfócitos e eosinófilos, que reduziram. Não existiram diferenças significativas (p<0,05) entre machos e fêmeas ao confrontar as relações antes/depois. Além disso, evidenciou-se que o valor da relação MI/MII para volume globular, hemoglobina e número de hemácias variou de acordo com a freqüência do exercício. Conclui-se que a prova de Team Peninng ocasiona alterações hematológicas em eqüinos, com interferência da freqüência do exercício, independente do sexo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polarization curves experimentally obtained in the electro-dissolution of iron in a 1 M H2SO4 solution using a rotating disc as the working electrode present a current instability region within the range of applied voltage in which the current is controlled by mass transport in the electrolyte. According to the literature (Barcia et. al., 1992) the electro-dissolution process leads to the existence of a viscosity gradient in the interface metal-solution, which leads to a velocity field quantitatively different form the one developed in uniform viscosity conditions and may affect the stability of the hydrodynamic field. The purpose of this work is to investigate whether a steady viscosity profile, depending on the distance to the electrode surface, affects the stability properties of the classic velocity field near a rotating disc. Two classes of perturbations are considered: perturbations monotonically varying along the radial direction, and perturbations periodically modulated along the radial direction. The results show that the hydrodynamic field is always stable with respect to the first class of perturbations and that the neutral stability curves are modified by the presence of a viscosity gradient in the second case, in the sense of reducing the critical Reynolds number beyond which perturbations are amplified. This result supports the hypothesis that the current oscillations observed in the polarization curve may originate from a hydrodynamic instability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared two electroretinography (ERG) electrodes in dogs using ERG standards of the International Society for Clinical Electrophysiology of Vision (ISCEV). Ten healthy Yorkshire terrier dogs (mean age, 2.80 ± 1.42 years; 6 females) weighing 5.20 ± 1.56 kg were evaluated using an ERG system for veterinary use. Dark- and light-adapted ERG responses were recorded using an ERG-Jet electrode and a fiber electrode prototype. The examinations were performed during 2 visits, 3 weeks apart. Both electrodes (ERG-Jet or fiber prototype) were used on each animal and the first eye to be recorded (OD × OS) was selected randomly. Three weeks later the examination was repeated on the same animal switching the type of electrode to be used that day and the first eye to be examined. The magnitude and waveform quality obtained with the two electrode types were similar for all ERG responses. ERG amplitudes and implicit times obtained from dogs using the fiber electrode prototype were comparable to those obtained with the ERG-Jet electrode for rod, maximal rod-cone summed, cone, and 30-Hz flicker responses. The fiber electrode prototype is a low-cost device, available as an alternative instrument for clinical veterinary ERG recording for retinal function assessment.