17 resultados para Fractal geometry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The implementation of local geodetic networks for georeferencing of rural properties has become a requirement after publication of the Georeferencing Technical Standard by INCRA. According to this standard, the maximum distance of baselines to GNSS L1 receivers is of 20 km. Besides the length of the baseline, the geometry and the number of geodetic control stations are other factors to be considered in the implementation of geodetic networks. Thus, this research aimed to examine the influence of baseline lengths higher than the regulated limit of 20 km, the geometry and the number of control stations on quality of local geodetic networks for georeferencing, and also to demonstrate the importance of using specific tests to evaluate the solution of ambiguities and on the quality of the adjustment. The results indicated that the increasing number of control stations has improved the quality of the network, the geometry has not influenced on the quality and the baseline length has influenced on the quality; however, lengths higher than 20 km has not interrupted the implementation, with GPS L1 receiver, of the local geodetic network for the purpose of georeferencing. Also, the use of different statistical tests, both for the evaluation of the resolution of ambiguities and for the adjustment, have enabled greater clearness in analyzing the results, which allow that unsuitable observations may be eliminated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fractal dimension has been employed as a useful parameter in the diagnosis of retinal disease. Avakian et al. (Curr Eye Res 2002; 24: 274-280), comparing the vascular pattern of normal patients with mild to moderate non-proliferative diabetic retinopathy (NPDR), found a significant difference between them only in the macular region. This significant difference in the box-counting fractal dimension of the macular region between normal and mild NPDR patients has been proposed as a method of precocious diagnosis of NPDR. The aim of the present study was to determine if fractal dimensions can really be used as a parameter for the early diagnosis of NPDR. Box-counting and information fractal dimensions were used to parameterize the vascular pattern of the human retina. The two methods were applied to the whole retina and to nine anatomical regions of the retina in 5 individuals with mild NPDR and in 28 diabetic but opthalmically normal individuals (controls), with age between 31 and 86 years. All images of retina were obtained from the Digital Retinal Images for Vessel Extraction (DRIVE) database. The results showed that the fractal dimension parameter was not sensitive enough to be of use for an early diagnosis of NPDR.