17 resultados para Equivalent circuits


Relevância:

10.00% 10.00%

Publicador:

Resumo:

From June to July 1999 an outbreak of acute respiratory illness occurred in the town of Iporanga. Out of a total of 4,837 inhabitants, 324 cases were notified to the Regional Surveillance Service. Influenza virus was isolated from 57.1% of the collected samples and 100% seroconversion to influenza A (H1N1) was obtained in 20 paired sera tested. The isolates were related to the A/Bayern/07/95 strain (H1N1). The percentages of cases notified during the outbreak were 28.4%, 29.0%, 20.7%, 6.2% and 15.7% in the age groups of 0-4, 5-9, 10-14, 15-19 and older than 20 years, respectively. The highest proportion of positives was observed among children younger than 14 years and no cases were notified in people older than 65 years, none of whom had been recently vaccinated against influenza. These findings suggest a significant vaccine protection against A/Bayern/7/95, the H1 component included in the 1997-98 influenza vaccine for elderly people. This viral strain is antigenically and genetically related to A/Beijing/262/95, the H1 component of the 1999 vaccine. Vaccines containing A/Beijing/262/95 (H1N1) stimulated post-immunization hemagglutination inhibition antibodies equivalent in frequency and titre to both A/Beijing/262/95-like and A/Bayern/7/95-like viruses. Thus, this investigation demonstrates the effectiveness of vaccination against influenza virus in the elderly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

HHV-6 is the etiological agent of Exanthem subitum which is considered the sixth most frequent disease in infancy. In immuno-compromised hosts, reactivation of latent HHV-6 infection may cause severe acute disease. We developed a Sybr Green Real Time PCR for HHV-6 and compared the results with nested conventional PCR. A 214 pb PCR derived fragment was cloned using pGEM-T easy from Promega system. Subsequently, serial dilutions were made in a pool of negative leucocytes from 10-6 ng/µL (equivalent to 2465.8 molecules/µL) to 10-9 (equivalent to 2.46 molecules/µL). Dilutions of the plasmid were amplified by Sybr Green Real Time PCR, using primers HHV3 (5' TTG TGC GGG TCC GTT CCC ATC ATA 3)'and HHV4 (5' TCG GGA TAG AAA AAC CTA ATC CCT 3') and by conventional nested PCR using primers HHV1 (outer): 5'CAA TGC TTT TCT AGC CGC CTC TTC 3'; HHV2 (outer): 5' ACA TCT ATA ATT TTA GAC GAT CCC 3'; HHV3 (inner) and HHV4 (inner) 3'. The detection threshold was determined by plasmid serial dilutions. Threshold for Sybr Green real time PCR was 24.6 molecules/µL and for the nested PCR was 2.46 molecules/µL. We chose the Real Time PCR for diagnosing and quantifying HHV-6 DNA from samples using the new Sybr Green chemistry due to its sensitivity and lower risk of contamination.