46 resultados para Computer software - Quality control
Resumo:
The aim of this study was to evaluate the application possibility of tabular CUSUM control charts in the quality control of chemical variables in surface water. It was performed bibliographic and field research to collect water samples from 2003 to 2009, totaling 30 samples, some monthly and others semi-annual in order to observe the variables that regulate water quality. It was found that these charts may be applied to control the quality of river water; showing to be effective in the perception of changes during the process, especially for small samples (n=1) which there is no repetition as in this research. It was also concluded that the Mandurim River does not presents significant levels of pollution.
Resumo:
ABSTRACTObjective:to analyze the implementation of a trauma registry in a university teaching hospital delivering care under the unified health system (SUS), and its ability to identify points for improvement in the quality of care provided.Methods:the data collection group comprised students from medicine and nursing courses who were holders of FAPESP scholarships (technical training 1) or otherwise, overseen by the coordinators of the project. The itreg (ECO Sistemas-RJ/SBAIT) software was used as the database tool. Several quality "filters" were proposed to select those cases for review in the quality control process.Results:data for 1344 trauma patients were input to the itreg database between March and November 2014. Around 87.0% of cases were blunt trauma patients, 59.6% had RTS>7.0 and 67% ISS<9. Full records were available for 292 cases, which were selected for review in the quality program. The auditing filters most frequently registered were laparotomy four hours after admission and drainage of acute subdural hematomas four hours after admission. Several points for improvement were flagged, such as control of overtriage of patients, the need to reduce the number of negative imaging exams, the development of protocols for achieving central venous access, and management of major TBI.Conclusion: the trauma registry provides a clear picture of the points to be improved in trauma patient care, however, there are specific peculiarities for implementing this tool in the Brazilian milieu.
Resumo:
The software Seed Vigor Imaging System (SVIS®), has been successfully used to evaluate seed physiological potential by automated analyses of scanned seedlings. In this research, the efficiency of this system was compared to other tests accepted for assessing cucumber (Cucumis sativus L.) seed vigor of distinct seed lots of Supremo and Safira cultivars. Seeds were subjected to germination, traditional and saturated salt accelerated aging, seedling emergence, seedling length and SVIS analyses (determination of vigor indices and seedling growth uniformity, lengths of primary root, hypocotyl and whole seedlings). It was also determined whether the definition of seedling growth/uniformity ratios affects the sensitivity of the SVIS®. Results showed that analyses SVIS have provided consistent identification of seed lots performance, and have produced information comparable to those from recommended seed vigor tests, thus demonstrating a suitable sensitivity for a rapid and objective evaluation of physiological potential of cucumber seeds. Analyses of four-days-old cucumber seedlings using the SVIS® are more accurate and growth/uniformity does not affect the precision of results.
Resumo:
OBJECTIVE: The assessment of an easy to prepare and low cost control material for Hematology, available for manual and automated methods. MATERIAL AND METHOD: Aliquots of stabilized whole blood were prepared by partial fixation with aldehydes; the stability at different temperatures (4. 20 and 37 °C) during periods of up to 8-9 weeks and aliquot variability with both methods were controlled. RESULTS: Aliquot variability with automated methods at day 1, expressed as CV% (coefficient of variation) was: white blood cells (WBC) 2.7, red blood cells (RBC) 0.7, hemoglobin (Hb) 0.6, hematocrit (Hct) 0.7, mean cell volume (MCV) 0.3, mean cell hemoglobin (MCH) 0.6, mean cell hemoglobin concentration (MCHC) 0.7, and platelets (PLT) 4.6. The CV (coefficient of variation) percentages obtained with manual methods in one of the batches were: WBC 23, Hct 2.8, Hb 4.5, MCHC 5.9, PLT 41. Samples stored at 4ºC and 20ºC showed good stability, only a very low initial hemolysis being observed, whereas those stored at 37ºC deteriobed a rapidly (metahemoglobin formation, aggregation of WBC and platelets, as well as alteration of erythrocyte indexes). CONCLUSIONS: It was confirmed that, as long as there is no exposure to high temperatures during distribution, this material is stable, allowing assessment, both esternal and internal, for control purposes, with acceptable reproductivity, both for manual and auttomatic methods.
Resumo:
OBJECTIVE: To evaluate the microbiological quality of treated and untreated water samples came from urban and rural communities and to examine the relationship between coliforms occurrence and average water temperature, and a comparison of the rainfall levels. METHODS: A sample of 3,073 untreated and treated (chlorinated) water from taps (1,594), reservoir used to store treated water (1,033), spring water (96) and private well (350) collected for routine testing between 1996 and 1999 was analyzed by the multiple dilution tube methods used to detect the most probable number of total and fecal coliforms. These samples were obtained in the region of Maringá, state of Paraná, Brazil. RESULTS: The highest numbers water samples contaminated by TC (83%) and FC (48%) were found in the untreated water. TC and FC in samples taken from reservoirs used to store treated water was higher than that from taps midway along distribution lines. Among the treated water samples examined, coliform bacteria were found in 171 of the 1,033 sampling reservoirs. CONCLUSIONS: Insufficient treatment or regrowth is suggested by the observation that more than 17% of these treated potable water contained coliform. TC and FC positive samples appear to be similar and seasonally influenced in treated water. Two different periods must be considered for the occurrence of both TC and FC positive samples: (i) a warm-weather period (September-March) with high percentage of contaminated samples; and (ii) cold-weather period (April-August) were they are lower. Both TC and TF positive samples declined with the decreased of water temperature.
Resumo:
The RID assay is one of the in vitro methods used for in-process control in the production of rabies vaccines for veterinary use. It has been shown to be very useful for determining antigen concentration in the final bulk product. The work presented in this paper, including the production and standardization of candidate standard reagents for use in the Radial Immunodiffusion Assay (RID) was carried out at the Pan American Institute for Food Protection and Zoonoses (INPPAZ/PAHO/WHO). The study was completed with the cooperation of the Faculty of Veterinary Sciences, National University of La Plata (NULP), Argentina, where the validation of the proposed standards and the quality control of samples from 28 different batches of rabies vaccines produced with Pasteur strain rabies virus (PV) in BHK cells were performed. The activity of the vaccines was determined by in vivo (NIH) and in vitro (RID)assays. The results of the candidate reagents for the reagent standardization tests showed stability, sensitivity and reproducibility. The Relative Potency the 1.2 between the problem vaccines and the reference vaccine was estimated by variance and regression analysis. The results of our validation study show that the INPPAZ (PAHO/WHO) is capable of producing and distributing the above-mentioned standard reagents, as well as of providing support for the incorporation of the RID technique (sensitive, rapid and inexpensive) to the laboratories that manufacture rabies vaccines in Latin America and the Caribbean.
Resumo:
Foodborne diseases represent operational risks in industrial restaurants. We described an outbreak of nine clustered cases of acute illness resembling acute toxoplasmosis in an industrial plant with 2300 employees. These patients and another 36 similar asymptomatic employees were diagnosed with anti-T. gondii IgG titer and avidity by ELISA. We excluded 14 patients based on high IgG avidity and chronic toxoplasmosis: 13 from controls and one from acute disease other than T. gondii infection. We also identified another three asymptomatic employees with T.gondii acute infection and also anti-T. gondii IgM positive as remaining acute cases. Case control study was conducted by interview in 11 acute infections and 20 negative controls. The ingestion of green vegetables, but not meat or water, was observed to be associated with the incidence of acute disease. These data reinforce the importance of sanitation control in industrial restaurants and also demonstrate the need for improvement in quality control regarding vegetables at risk for T. gondii oocyst contamination. We emphasized the accurate diagnosis of indexed cases and the detection of asymptomatic infections to determine the extent of the toxoplasmosis outbreak.
Resumo:
INTRODUCTION: The emergence of drug resistance is one of the main problems concerning malaria treatment. The use of counterfeit and/or substandard antimalarial drugs can contribute to the development of parasite resistance. Thus, the aim of this study was to evaluate the quality of antimalarial drugs distributed in Brazil. METHODS: Samples containing chloroquine phosphate, mefloquine hydrochloride, primaquine phosphate, and quinine sulfate tablets were delivered to the Rio de Janeiro central storeroom (CENADI), state storerooms (SS), and Basic Health Units (BHUs) in the north region of Brazil - a total of 10 sample sets. After 5 months of storage, the samples were collected, and in vitro quality control analyses according to official and published methods were performed. RESULTS: Inadequate drug storage conditions were found in two SS and in all BHUs evaluated. There were no quality deviations found in the chloroquine samples. The quinine samples exhibited weight variation above the allowed limits. The primaquine samples were found to have packaging deficiency. The release of mefloquine in samples from some regions showed a statistically significant difference when compared with the CENADI samples. CONCLUSIONS: It is important to periodically evaluate the quality and storage conditions of essential drugs. The quality deviations found with the primaquine and quinine samples are not related to storage conditions and must be addressed urgently. The decreased mefloquine release from tablets is related to formulation problems or influenced by inadequate storage conditions, prompting further investigation. Even with the mentioned problems, the samples would probably not contribute to resistant parasite selection.
Resumo:
Objective:To evaluate the evolution of mammographic image quality in the state of Rio de Janeiro on the basis of parameters measured and analyzed during health surveillance inspections in the period from 2006 to 2011.Materials and Methods:Descriptive study analyzing parameters connected with imaging quality of 52 mammography apparatuses inspected at least twice with a one-year interval.Results:Amongst the 16 analyzed parameters, 7 presented more than 70% of conformity, namely: compression paddle pressure intensity (85.1%), films development (72.7%), film response (72.7%), low contrast fine detail (92.2%), tumor mass visualization (76.5%), absence of image artifacts (94.1%), mammography-specific developers availability (88.2%). On the other hand, relevant parameters were below 50% conformity, namely: monthly image quality control testing (28.8%) and high contrast details with respect to microcalcifications visualization (47.1%).Conclusion:The analysis revealed critical situations in terms of compliance with the health surveillance standards. Priority should be given to those mammography apparatuses that remained non-compliant at the second inspection performed within the one-year interval.
Resumo:
In this work we show how to build a piece of equipment for depositing thin films by the dip-coating process, using inexpensive components easily found on the market. This equipment allows us to control the dipping and pulling velocity at which the substrate is put in the film precursor solution, two very important parameters for obtain thin films. This article discusses the construction of the mechanical and electric parts of the equipment, a simple method to interface it to a computer and the development of the software to control the dip-coating parameters.
Resumo:
Intermolecular forces are a useful concept that can explain the attraction between particulate matter as well as numerous phenomena in our lives such as viscosity, solubility, drug interactions, and dyeing of fibers. However, studies show that students have difficulty understanding this important concept, which has led us to develop a free educational software in English and Portuguese. The software can be used interactively by teachers and students, thus facilitating better understanding. Professors and students, both graduate and undergraduate, were questioned about the software quality and its intuitiveness of use, facility of navigation, and pedagogical application using a Likert scale. The results led to the conclusion that the developed computer application can be characterized as an auxiliary tool to assist teachers in their lectures and students in their learning process of intermolecular forces.
Resumo:
The current study used statistical methods of quality control to evaluate the performance of a sewage treatment station. The concerned station is located in Cascavel city, Paraná State. The evaluated parameters were hydrogenionic potential, settleable solids, total suspended solids, chemical oxygen demand and biochemical oxygen demand in five days. Statistical analysis was performed through Shewhart control charts and process capability ratio. According to Shewhart charts, only the BOD(5.20) variable was under statistical control. Through capability ratios, we observed that except for pH the sewage treatment station is not capable to produce effluents under characteristics that fulfill specifications or standard launching required by environmental legislation.
Resumo:
Objective The objective of this study is to assess the performance of cytopathology laboratories providing services to the Brazilian Unified Health System (Sistema Único de Saúde - SUS) in the State of Minas Gerais, Brazil. Methods This descriptive study uses data obtained from the Cervical Cancer Information System from January to December 2012. Three quality indicators were analyzed to assess the quality of cervical cytopathology tests: positivity index, percentage of atypical squamous cells (ASCs) in abnormal tests, and percentage of tests compatiblewith high-grade squamous intraepithelial lesions (HSILs). Laboratories were classified according to their production scale in tests per year≤5,000; from 5,001 to 10,000; from 10,001 to 15,000; and 15,001. Based on the collection of variables and the classification of laboratories according to production scale, we created and analyzed a database using Microsoft Office Excel 97-2003. Results In the Brazilian state of Minas Gerais, 146 laboratories provided services to the SUS in 2012 by performing a total of 1,277,018 cervical cytopathology tests. Half of these laboratories had production scales≤5,000 tests/year and accounted for 13.1% of all tests performed in the entire state; in turn, 13.7% of these laboratories presented production scales of > 15,001 tests/year and accounted for 49.2% of the total of tests performed in the entire state. The positivity indexes of most laboratories providing services to the SUS in 2012, regardless of production scale, were below or well below recommended limits. Of the 20 laboratories that performed more than 15,001 tests per year, only three presented percentages of tests compatible with HSILs above the lower limit recommended by the Brazilian Ministry of Health. Conclusion The majority of laboratories providing services to the SUS in Minas Gerais presented quality indicators outside the range recommended by the Brazilian Ministry of Health.
Resumo:
The augmented reality (AR) technology has applications in many fields as diverse as aeronautics, tourism, medicine, and education. In this review are summarized the current status of AR and it is proposed a new application of it in weed science. The basic algorithmic elements for AR implementation are already available to develop applications in the area of weed economic thresholds. These include algorithms for image recognition to identify and quantify weeds by species and software for herbicide selection based on weed density. Likewise, all hardware necessary for AR implementation in weed science are available at an affordable price for the user. Thus, the authors propose weed science can take a leading role integrating AR systems into weed economic thresholds software, thus, providing better opportunities for science and computer-based weed control decisions.
Resumo:
The adaptive behavior of human beings is usually supported by rapid monitoring of outstanding events in the environment. Some investigators have suggested that a primary attention deficit might trigger symptoms of schizophrenia. In addition, researchers have long discussed the relationship between schizophrenia and the schizophrenia-like psychosis of epilepsy (SLPE). On the basis of these considerations, the objective of the present study was to investigate attention performance of patients with both disorders. Patient age was 18 to 60 years, and all patients had received formal schooling for at least four years. Patients were excluded if they had any systemic disease with neurologic or psychiatric comorbidity, or a history of brain surgery. The computer-assisted TAVIS-2R test was applied to all patients and to a control group to evaluate and discriminate between selective, alternating and sustained attention. The TAVIS-2R test is divided into three parts: one for selective attention (5 min), the second for alternating attention (5 min), and the third for the evaluation of vigilance or sustained attention (10 min). The same computer software was used for statistical analysis of reaction time, omission errors, and commission errors. The sample consisted of 36 patients with schizophrenia, 28 with interictal SLPE, and 47 healthy controls. The results of the selective attention tests for both patient groups were significantly lower than that for controls. The patients with schizophrenia and SLPE performed differently in the alternating and sustained attention tests: patients with SLPE had alternating attention deficits, whereas patients with schizophrenia showed deficits in sustained attention. These quantitative results confirmed the qualitative clinical observations for both patient groups, that is, that patients with schizophrenia had difficulties in focusing attention, whereas those with epilepsy showed perseveration in attention focus.