85 resultados para Breast
Resumo:
Objective: To gather, to characterize, to analyze, to synthesize and to integrate primary studies that addressed the experiences of spouses / husbands / partners of women with breast cancer, presenting the current state of knowledge. Method: Integrative literature review carried out in the databases of VHL, PubMed, CINHAL e SciELO. Results: The sample consisted of eight studies published between 2000-2012, which pointed to the experiences of the involvement and the care of the husbands towards their ill wives. Conclusion: This study highlights the need for attention and assistance to those spouses, as well as guidance and education to exercise the care the same way as the health staff has done with women. Furthermore, it emphasizes the importance of further studies in order to deepen the knowledge on this topic, and thus, improve the care with better scientific basis.
Resumo:
Comprehensive approach study aimed understanding the reflections and contrasts between personal time and medical therapy protocol time in the life of a young woman with breast cancer. Addressed as a situational study and grounded in Beth’s life story about getting sick and dying of cancer at age 34, the study’s data collection process employed interviews, observation and medical record analysis. The construction of the analytic-synthetic box based on the chronology of Beth’s clinical progression, treatment phases and temporal perception of occurrences enabled us to point out a linear medical therapy protocol time identified by the diagnosis and treatment sequencing process. On the other hand, Beth’s experienced time was marked by simultaneous and non-linear events that generated suffering resulting from the disease. Such comprehension highlights the need for healthcare professionals to take into account the time experienced by the patient, thus providing an indispensable cancer therapeutic protocol with a personal character.
Opportunistic screening actions for breast cancer performed by nurses working in primary health care
Resumo:
Abstract OBJECTIVE To identify opportunistic screening actions for breast cancer performed by nurses working in primary health care units in Ribeirão Preto, São Paulo. METHOD Cross-sectional study with 60 nurses from 28 units, who had been working for at least one year in the public municipal health care network. Data were collected between December 2013 and March 2014, by means of a questionnaire, using descriptive analysis and the software IBM SPSS version 20 and Microsoft Excel 2010. RESULTS The results showed that 71.7% of the participants questioned their female patients as for risk factors for breast cancer, mainly during nursing consultation; 70.0% oriented users about the age to perform clinical breast exam, whereas 30.0% did not due to lack of knowledge and time; 60.0% explained about the age to perform mammogram; 73.3% did not refer patients with suspicious breast exam results to the referral department, citing scheduling as the main obstacle to referral. Educational activities were not performed by 78.3% of participants. CONCLUSION Investment is needed in professional training and management of breast cancer screening.
Resumo:
O Breast Imaging Reporting and Data System (BI-RADS™), do American College of hRadiology, foi concebido para padronizar o laudo mamográfico e reduzir os fatores de confusão na descrição e interpretação das imagens, além de facilitar o monitoramento do resultado final. OBJETIVO: Identificar a maneira como vem sendo utilizado o BI-RADS™, gerando informações que possam auxiliar o Colégio Brasileiro de Radiologia a desenvolver estratégias para aperfeiçoar o seu uso. MATERIAIS E MÉTODOS: Os dados foram coletados na cidade de Goiânia, GO. Foram solicitados os exames de mamografia anteriores a todas as mulheres que se dirigiram ao serviço para realização de mamografia entre janeiro/2003 e junho/2003. Foram incluídos na análise exames anteriores, realizados entre 1/7/2001 e 30/6/2003. RESULTADOS: Foram coletados 104 laudos anteriores, emitidos por 40 radiologistas de 33 diferentes serviços. Dos 104 laudos, 77% (n = 80) utilizavam o BI-RADS™. Destes, apenas 15% (n = 12) eram concisos, nenhum utilizava a estrutura e organização recomendadas pelo sistema, 98,75% (n = 79) não respeitavam o léxico e 65% (n = 51) não faziam recomendação de conduta. CONCLUSÃO: O BI-RADS™, apesar de bastante utilizado, não foi reconhecido como sistema para padronização dos laudos. Foi usado quase exclusivamente como forma de classificação final dos exames.
Resumo:
OBJETIVO: Avaliar artigos, na literatura, que verificam o valor preditivo positivo das categorias 3, 4 e 5 do Breast Imaging Reporting and Data System (BI-RADS®). MATERIAIS E MÉTODOS: Foi realizada pesquisa na base de dados Medline utilizando os termos "predictive value" e "BI-RADS". Foram incluídos 11 artigos nesta revisão. RESULTADOS: O valor preditivo positivo das categorias 3, 4 e 5 variou entre 0% e 8%, 4% e 62%, 54% e 100%, respectivamente. Três artigos avaliaram, concomitantemente, os critérios morfológicos das lesões que apresentaram maior valor preditivo positivo na mamografia, sendo nódulo espiculado o critério com maior valor preditivo positivo. CONCLUSÃO: Houve grande variabilidade do valor preditivo positivo das categorias 3, 4 e 5 do BI-RADS® em todos os estudos, porém foram identificadas diferenças metodológicas que limitaram a comparação desses estudos.
Resumo:
OBJETIVO: O objetivo deste trabalho foi avaliar o BI-RADS® como fator preditivo de suspeição de malignidade em lesões mamárias não palpáveis nas categorias 3, 4 e 5, correlacionando as mamografias com os resultados histopatológicos através do cálculo do valor preditivo positivo do exame mamográfico. MATERIAIS E MÉTODOS: Trezentas e setenta e uma pacientes encaminhadas a um serviço de referência em tratamento de câncer em Teresina, PI, para realização de exames histopatológicos em mama no período de julho de 2005 a março de 2008, por terem mamografia de categorias 3, 4 ou 5, tiveram seus exames revisados. Das 371 pacientes, 265 foram submetidas a biópsia por agulha grossa e 106, a marcação pré-cirúrgica. RESULTADOS: Em relação às mamografias, 11,32% foram classificadas como categoria 3, 76,28% como categoria 4 e 12,4% como categoria 5. Os resultados histológicos demonstraram 24% de exames positivos para malignidade. Os valores preditivos positivos das categorias 3, 4 e 5 foram, respectivamente, de 7,14%, 16,96% e 82,61%. Foram calculados os valores preditivos positivos, separadamente, para as biópsias percutâneas (7,14%, 15,76%, 76,47%) e para as marcações pré-cirúrgicas (7,14%, 20%, 100%). CONCLUSÃO: Achados malignos foram subestimados pelo laudo radiológico e houve superestimação de achados benignos, o que resultou na realização desnecessária de alguns procedimentos invasivos.
Resumo:
New injectable fillers such as hyaluronic acid have recently been employed as a non-surgical alternative to implants such as silicone for aesthetic breast enhancement. Although their utilization is not yet widespread in Brazil, radiologists should be aware of the imaging findings in this context and of the implications of the presence of this filler for the radiological evaluation in the screening for breast cancer.
Resumo:
Objective To evaluate the BI-RADS as a predictive factor of suspicion for malignancy in breast lesions by correlating radiological with histological results and calculating the positive predictive value for categories 3, 4 and 5 in a breast cancer reference center in the city of São Paulo. Materials and Methods Retrospective, analytical and cross-sectional study including 725 patients with mammographic and/or sonographic findings classified as BI-RADS categories 3, 4 and 5 who were referred to the authors' institution to undergo percutaneous biopsy. The tests results were reviewed and the positive predictive value was calculated by means of a specific mathematical equation. Results Positive predictive values found for categories 3, 4 and 5 were respectively the following: 0.74%, 33.08% and 92.95%, for cases submitted to ultrasound-guided biopsy, and 0.00%, 14.90% and 100% for cases submitted to stereotactic biopsy. Conclusion The present study demonstrated high suspicion for malignancy in lesions classified as category 5 and low risk for category 3. As regards category 4, the need for systematic biopsies was observed.
Resumo:
Objective To compare the capacity of mammography, sonoelastography, B-mode ultrasonography and histological analysis to differentiate benign from malignant breast lesions. Materials and Methods A total of 12 histopathologically confirmed breast lesions were documented. The lesions were assessed by means of mammography, B-mode ultrasonography and sonoelastography, and histopathological analysis was utilized as a gold standard. Sensitivity and specificity were calculated. A receiver operating characteristic (ROC) curve was constructed to evaluate the diagnostic performance of the mentioned techniques. Results Sensitivity and specificity in the differentiation between benign and malignant lesions were respectively 100% and 50% for mammography, 100% and 71% for B-mode ultrasonography, and 67% and 83% for sonoelastography. The area under the ROC curve was calculated for the three imaging modalities and corresponded to 0.792 for mammography, 0.847 for B-mode ultrasonography, and 0.806 for sonoelastography. Conclusion Sonoelastography demonstrated higher specificity and lower sensitivity as compared with mammography and B-mode ultrasonography. On the other hand, B-mode ultrasonography had the largest area under the ROC curve. Sonoelastography has demonstrated to be a promising technique to detect and evaluate breast lesions, and could potentially reduce the number of unnecessary biopsies.
Resumo:
Ultrasound-guided core-needle biopsy has high sensitivity in the diagnosis of breast cancer. The present study is aimed at detailing the main steps of such procedure, including indications, advantages, limitations, follow-up and description of the technique, besides presenting a checklist including the critical steps required for an appropriate practice of the technique. In the recent years, an increasing number of patients have required breast biopsy, indicating the necessity of a proportional increase in the number of skilled professionals to carry out the procedures and histological diagnoses. A multidisciplinary approach involving the tripod clinical practice-radiology-pathology is responsible for the highest rate of accuracy of the technique and must always be adopted.
Resumo:
The present essay is aimed at describing the most characteristic imaging findings of mucinous carcinoma of the breast, with emphasis on the patterns related to better prognosis. The authors selected cases of mucinous carcinoma of the breast whose images were available, highlighting the imaging findings suggestive of this subtype of breast cancer, either at mammography, ultrasonography or magnetic resonance imaging.
Bilateral breast swelling secondary to superior vena cava obstruction and subclavian vein thrombosis
Resumo:
Superior vena cava syndrome is defined by a set of signs and symptoms secondary to superior vena cava obstruction caused principally by malignant diseases. The present report describes the case of an unusual clinical manifestation of this syndrome with bilateral breast swelling, and emphasizes the relevance of knowledge on mammographic signs of systemic diseases.
Resumo:
Objective To correlate the results of 18F-fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) performed with a specific protocol for assessment of breasts with histological/immunohistochemical findings in breast carcinoma patients. Materials and Methods Cross-sectional study with prospective data collection, where patients with biopsy-confirmed breast carcinomas were studied. The patients underwent PET/CT examination in prone position, with a specific protocol for assessment of breasts. PET/CT findings were compared with histological and immunohistochemical data. Results The authors identified 59 malignant breast lesions in 50 patients. The maximum diameter of the lesions ranged from 6 to 80 mm (mean: 32.2 mm). Invasive ductal carcinoma was the most common histological type (n = 47; 79.7%). At PET/CT, 53 (89.8%) of the lesions demonstrated anomalous concentrations of 18F-FDG, with maximum SUV ranging from 0.8 to 23.1 (mean: 5.5). A statistically significant association was observed between higher values of maximum SUV and histological type, histological grade, molecular subtype, tumor diameter, mitotic index and Ki-67 expression. Conclusion PET/CT performed with specific protocol for assessment of breasts has demonstrated good sensitivity and was associated with relevant histological/immunohistochemical factors related to aggressiveness and prognosis of breast carcinomas.