29 resultados para Back-arc Extension
Resumo:
Objective: To assess the efficacy of massage for decreasing occupational low back pain in workers of a Nursing team in an Emergency Room. Method: A randomized controlled trial, using a socio-demographic/morbidity questionnaire and a Pain Numeric Scale. Forty-five subjects were randomly allocated for intervention (G1 – Massage by acupressure), placebo group (G2 – application of Garlium Arseneid Laser 904nm turned off) and control (G3 – no intervention). Results: The main triggering factor, as well as the worsening of pain, was the patient manipulation, both with a prevalence of 34.9%. The main treatment for low back pain before this research was the use of medication, with a prevalence of 44.2%. In accordance with a variance analysis, only G1 presented a significant statistical difference, with a better result after 12 sessions. Massage presented an enormous effect (d = 4.59), corresponding to 86% of reduction in the pain level. Conclusion: Massage was effective to decrease occupational low back pain of those Nursing workers.
Resumo:
A metallic-sample arc-furnace was modified to synthesize fullerenes and nanotubes. The (reversible) changes and the process for producing single-wall nanotubes (SWNTs) are described.
Resumo:
A martensitic single crystal Cu-23.95Zn-3.62(wt.%)Al alloy was obtained melting pure Cu, Zn and Al using Bridgman's method. The martensitic phase (monoclinic) can present up to 24 variants, and orienting the surface according to a certain plane is a very hard task. The single crystal was submitted to 8 tons of tension (stress) along the longitudinal direction to reduce the number of variants and facilitate the surface orientation according to the desired plane. This single crystal was oriented using the Laüe back-reflection method to give surfaces with the following oriented crystallographic planes: (010), (120) and (130). It was observed that the tension stress was applied along the [010] direction.
Resumo:
The black spot of citrus (Citrus sp.) is caused by Guignardia citricarpa with ascospore production depending on temperature, leaf wetness, and rainfall. The number of ascospores produced was monitored using a spore trap and climatic factors were recorded using an automated meteorological station of 'Natal' and 'Valencia' sweet orange (Citrus sinensis) orchards in Mogi Guaçu in the state of São Paulo, Brazil, from November 2000 to March 2001. The fruits were bagged to prevent infection and the bags removed from different sets of fruit for one week during each of the 18 weeks of the season in both orchards. Ascospores were produced during the entire experimental period, from spring through summer, primarily after rain events. In both orchards, ascospore production reached a peak in January and February. Ascospore production was related to leaf wetness only in the Natal orange orchard but was not related to total rainfall or temperature in either orchard. Disease was most severe on fruit exposed the 7th, 8th, and 13th weeks after beginning the experiment in both cultivars as well as after the 16th week for 'Natal'. There was a strong relationship between disease severity and total rainfall for both orchards and a weak correlation between temperature and severity in the 'Natal' block only. There was no relationship between severity and leaf wetness or ascospore numbers.
Resumo:
Objective : to evaluate the effect of topical delivery of latex cream-gel in acute cutaneous wounds induced on the back of rats. Methods : we subjected sixteen rats to dermo-epidermal excision of a round dorsal skin flap, with 2.5cm diameter. We divided the animals into two groups: Latex Group: application of cream-gel-based latex throughout the wound bed on postoperative days zero, three, six and nine; Control group: no treatment on the wound. Photographs of the lesions were taken on the procedure day and on the 6th and 14th postoperative days, for analyzing the area and the larger diameter of the wound. We carried out euthanasia of all animals on the 14th postoperative day, when we resected he dorsal skin and the underlying muscle layer supporting the wound for histopathological study. Results : there was no statistically significant difference in the percentage of wound closure, in the histopathological findings or in the reduction of the area and of the largest diameter of the wounds among the groups studied on the 14th postoperative day. Conclusion : according to the experimental conditions in which the study was conducted, latex cream-gel did not interfere in the healing of acute cutaneous wounds in rats.
Resumo:
Self-fluxed nickel alloys are usually flame fused after thermal spraying. However, due to the practical aspects of high temperatures reached during flame fusing, large structures such as the hydraulic turbines for power generation, can not be efficiently coated. An alternative is to fuse the sprayed coating with a gas tungsten electric arc. In this case, heating is much more intensive and substrate temperature during and after the fusing operation is much lower, thus reducing the possibility that any problem will occur. In this work, coatings of self-fluxed nickel alloy fused by flame and gas tungsten arc were evaluated as protection of hydraulic turbines against cavitational damage. Several tests were performed, including the ASTM ultrasonically vibration-induced cavitation, optical and scanning electronic microscopic metallography, and hardness tests. The results showed that the arc-fused coating presented better cavitation damage resistance, probably due to its finer microstructure. A field application of this new technique is also described. A self-fluxed Ni alloy was flame sprayed in critical regions of Francis-type hydraulic turbine blades and fused by a gas tungsten arc after spraying. The blades will be inspected during the next two years.
Resumo:
The application of flux cored arc welding (FCAW) has increased in manufacturing and fabrication. Even though FCAW is well known for its good capability in producing quality welds, few reports have been published on the cause of the relatively high diffusible hydrogen content in the weld metal and its relation with the ingredients used in the wire production and with the welding parameters (mainly welding current). This paper describes experiments where data obtained from weld metal diffusible hydrogen analysis, metal droplet collection, and high-speed recording of metal droplet transfer were used to evaluate the effect of welding current on diffusible hydrogen content in the weld metal. The results from gas chromatography analysis showed that weld metal hydrogen content indeed increased with welding current. A polynomial regressional analysis concluded that hydrogen increase with current was better described by a linear function with proportional constant of approximately 0.7 or 70%. Different from the GMA welding transfer behavior, statistical analysis showed only a small increase in metal droplet size with increasing current. The metal transfer mode remained in the globular range for currents between 100 and 150 A. The most surprising findings were with the high-speed cinematography recording. Observing the high speed movies, it was possible to see that at low current, "unmelted" flux sporadically touched the weld pool but at higher current, the flux remained touching the weld pool during the whole time of droplet formation and transfer. It is believed that since the flux has ingredients that contain hydrogen, hydrogen passes through the arc undisturbed, going to the weld bead intact and increasing the hydrogen content in the weld metal. Another important observation is regarding to droplet size. Droplet size increased with increasing current because forces from decomposed gases from the flux could sustain the droplets, retarding their transfer and allowing them to grow.
Resumo:
Magnesium and its alloys have recently been used in the development of lightweight, biodegradable implant materials. However, the corrosion properties of magnesium limit its clinical application. The purpose of this study was to comprehensively evaluate the degradation behavior and biomechanical properties of magnesium materials treated with micro-arc oxidation (MAO), which is a new promising surface treatment for developing corrosion resistance in magnesium, and to provide a theoretical basis for its further optimization and clinical application. The degradation behavior of MAO-treated magnesium was studied systematically by immersion and electrochemical tests, and its biomechanical performance when exposed to simulated body fluids was evaluated by tensile tests. In addition, the cell toxicity of MAO-treated magnesium samples during the corrosion process was evaluated, and its biocompatibility was investigated under in vivo conditions. The results of this study showed that the oxide coating layers could elevate the corrosion potential of magnesium and reduce its degradation rate. In addition, the MAO-coated sample showed no cytotoxicity and more new bone was formed around it during in vivo degradation. MAO treatment could effectively enhance the corrosion resistance of the magnesium specimen and help to keep its original mechanical properties. The MAO-coated magnesium material had good cytocompatibility and biocompatibility. This technique has an advantage for developing novel implant materials and may potentially be used for future clinical applications.
Resumo:
Intracutaneous sterile water injection (ISWI) is used for relief of low back pain during labor, acute attacks of urolithiasis, chronic neck and shoulder pain following whiplash injuries, and chronic myofascial pain syndrome. We conducted a randomized, double-blinded, placebo-controlled trial to evaluate the effect of ISWI for relief of acute low back pain (aLBP). A total of 68 patients (41 females and 27 males) between 18 and 55 years old experiencing aLBP with moderate to severe pain (scores ≥5 on an 11-point visual analogue scale [VAS]) were recruited and randomly assigned to receive either ISWIs (n=34) or intracutaneous isotonic saline injections (placebo treatment; n=34). The primary outcome was improvement in pain intensity using the VAS at 10, 45, and 90 min and 1 day after treatment. The secondary outcome was functional improvement, which was assessed using the Patient-Specific Functional Scale (PSFS) 1 day after treatment. The mean VAS score was significantly lower in the ISWI group than in the control group at 10, 45, and 90 min, and 1 day after injection (P<0.05, t-test). The mean increment in PSFS score of the ISWI group was 2.9±2.2 1 day after treatment, while that in the control group was 0.9±2.2. Our study showed that ISWI was effective for relieving pain and improving function in aLBP patients at short-term follow-up. ISWI might be an alternative treatment for aLBP patients, especially in areas where medications are not available, as well as in specific patients (e.g., those who are pregnant or have asthma), who are unable to receive medications or other forms of analgesia because of side effects.
Resumo:
The objective of this work was to study the effect of adding wheat fiber and partial pork back fat on the quality characteristics of bologna sausage. The compound central rotating design was used with treatments containing fixed levels of inulin (5%) and oat fiber (1%) and variable levels of wheat fiber (0-4%) and pork back fat (0-10%). The pH and protein were similar in all the treatments, the fat was lower than the control treatment and the moisture content was higher than the control treatment (CF) without fibers. The wheat fiber increased the hardness and reduced cohesiveness and scores were given for overall impression. We found that it was possible to prepare low-fat bologna sausage with the addition of 6.58% fiber (5% inulin, 1% oat fiber and 0.58% wheat fiber), whilst retaining good sensory acceptability, thus reducing the pork back fat levels by between 25 and 42.75%.