42 resultados para Automatic Image Annotation
                                
Resumo:
Objective:To evaluate the evolution of mammographic image quality in the state of Rio de Janeiro on the basis of parameters measured and analyzed during health surveillance inspections in the period from 2006 to 2011.Materials and Methods:Descriptive study analyzing parameters connected with imaging quality of 52 mammography apparatuses inspected at least twice with a one-year interval.Results:Amongst the 16 analyzed parameters, 7 presented more than 70% of conformity, namely: compression paddle pressure intensity (85.1%), films development (72.7%), film response (72.7%), low contrast fine detail (92.2%), tumor mass visualization (76.5%), absence of image artifacts (94.1%), mammography-specific developers availability (88.2%). On the other hand, relevant parameters were below 50% conformity, namely: monthly image quality control testing (28.8%) and high contrast details with respect to microcalcifications visualization (47.1%).Conclusion:The analysis revealed critical situations in terms of compliance with the health surveillance standards. Priority should be given to those mammography apparatuses that remained non-compliant at the second inspection performed within the one-year interval.
                                
Resumo:
In general, laboratory activities are costly in terms of time, space, and money. As such, the ability to provide realistically simulated laboratory data that enables students to practice data analysis techniques as a complementary activity would be expected to reduce these costs while opening up very interesting possibilities. In the present work, a novel methodology is presented for design of analytical chemistry instrumental analysis exercises that can be automatically personalized for each student and the results evaluated immediately. The proposed system provides each student with a different set of experimental data generated randomly while satisfying a set of constraints, rather than using data obtained from actual laboratory work. This allows the instructor to provide students with a set of practical problems to complement their regular laboratory work along with the corresponding feedback provided by the system's automatic evaluation process. To this end, the Goodle Grading Management System (GMS), an innovative web-based educational tool for automating the collection and assessment of practical exercises for engineering and scientific courses, was developed. The proposed methodology takes full advantage of the Goodle GMS fusion code architecture. The design of a particular exercise is provided ad hoc by the instructor and requires basic Matlab knowledge. The system has been employed with satisfactory results in several university courses. To demonstrate the automatic evaluation process, three exercises are presented in detail. The first exercise involves a linear regression analysis of data and the calculation of the quality parameters of an instrumental analysis method. The second and third exercises address two different comparison tests, a comparison test of the mean and a t-paired test.
                                
Resumo:
Some beetle species can have devastating economic impacts on forest and nursery industries. A recent example is Anophophora glabripennis, a species of beetle known in the United States as the ''Asian Longhorrned beetle'', which has damaged many American forests, and is a threat which can unintentionally reach south American countries, including Brazil. This work presents a new method based on X-ray computerized tomography (CT) and image processing for beetle injury detection in forests. Its results show a set of images with correct identification of the location of beetles in living trees as well as damage evaluation with time.
                                
Resumo:
The research proposes a methodology for assessing broiler breeder response to changes in rearing thermal environment. The continuous video recording of a flock analyzed may offer compelling evidences of thermal comfort, as well as other indications of welfare. An algorithm for classifying specific broiler breeder behavior was developed. Videos were recorded over three boxes where 30 breeders were reared. The boxes were mounted inside an environmental chamber were ambient temperature varied from cold to hot. Digital images were processed based on the number of pixels, according to their light intensity variation and binary contrast allowing a sequence of behaviors related to welfare. The system used the default of x, y coordinates, where x represents the horizontal distance from the top left of the work area to the point P, and y is the vertical distance. The video images were observed, and a grid was developed for identifying the area the birds stayed and the time they spent at that place. The sequence was analyzed frame by frame confronting the data with specific adopted thermal neutral rearing standards. The grid mask overlapped the real bird image. The resulting image allows the visualization of clusters, as birds in flock behave in certain patterns. An algorithm indicating the breeder response to thermal environment was developed.
                                
Resumo:
The use of precision farming tools in pesticide application technology can improve the techniques effectiveness during the spraying. Thus, this study aimed to compare automatic and manual systems to interrupt the syrup flow in the spray bar sections when applied in overlapped areas. The sprayings were carried out in eight places in completely randomized design. It was compared the spray consumption and the sprayed area in relation to the total area. The results indicated that in sprays performed with the automatic system there was an average savings of 17.2% of the sprayed volume. The sprayed area using the bar section's automatic control was an average 6.1% lower than the sprayed area with manual control.
                                
Resumo:
ResumoOBJETIVOValidar o instrumento Body Image Relationship Scale (BIRS) em mulheres brasileiras acometidas pelo câncer de mamaMÉTODOSO instrumento foi aplicado por entrevistadoras treinadas em 139 usuárias do Sistema Único de Saúde que foram submetidas aos tratamentos do câncer entre 2006 e 2010. O instrumento foi aferido considerando-se a consistência interna e a confiabilidade. Para efeito de comparação as técnicas de análise fatorial utilizadas no artigo original foram aplicadasRESULTADOSO valor de correlação Spearman-Brown foi 0,8, o que indica alto nível de confiabilidade, e o alfa de Cronbach encontrado foi 0,9, indicando alto nível de consistência interna. A análise fatorial mostrou que quatro questões não tinham poder discriminatório e carga fatorial baixa e outras cinco foram realocadas em outros domínios. Dessa forma, foi aplicada e mostrou variabilidade semelhante ao instrumento originalCONCLUSÃOA versão brasileira do BIRS, renomeada como Escala de Relacionamento e Imagem Corporal (ERIC), apresentou evidências de adequada confiabilidade e consistência interna, o que torna esse instrumento recomendável para aplicação em mulheres brasileiras com câncer de mama, apesar de alguns poucos limites
                                
Resumo:
Fifty Bursa of Fabricius (BF) were examined by conventional optical microscopy and digital images were acquired and processed using Matlab® 6.5 software. The Artificial Neuronal Network (ANN) was generated using Neuroshell® Classifier software and the optical and digital data were compared. The ANN was able to make a comparable classification of digital and optical scores. The use of ANN was able to classify correctly the majority of the follicles, reaching sensibility and specificity of 89% and 96%, respectively. When the follicles were scored and grouped in a binary fashion the sensibility increased to 90% and obtained the maximum value for the specificity of 92%. These results demonstrate that the use of digital image analysis and ANN is a useful tool for the pathological classification of the BF lymphoid depletion. In addition it provides objective results that allow measuring the dimension of the error in the diagnosis and classification therefore making comparison between databases feasible.
                                
Resumo:
Trough computed tomography (CT), it is possible to evaluate lymph nodes in detail and to detect changes in these structures earlier than with radiographs and ultrasound. Lack of information in the veterinary literature directed the focus of this report to normal aspects of the axillary and mediastinal lymph nodes of adult dogs on CT imaging. A CT scan of 15 normal adult male and female Rottweilers was done. To define them as clinically sound, anamnesis, physical examination, complete blood count, renal and hepatic biochemistry, ECG, and thoracic radiographs were performed. After the intravenous injection of hydrosoluble ionic iodine contrast medium contiguous 10mm in thickness thoracic transverse images were obtained with an axial scanner. In the obtained images mediastinal and axillary lymph nodes were sought and when found measured in their smallest diameter and their attenuation was compared to musculature. Mean and standard deviation of: age, weight, body length and the smallest diameter of the axillary and mediastinal lymph nodes were determined. Mean and standard deviation of parameters: age 3.87±2.03 years, weight 41.13±5.12, and body length 89.61±2.63cm. Axillary lymph nodes were seen in 60% of the animals, mean of the smallest diameter was 3.58mm with a standard deviation of 2.02 and a minimum value of 1mm and a maximum value of 7mm. From 13 observed lymph nodes 61.53% were hypopodense when compared with musculature, and 30.77% were isodense. Mediastinal lymph nodes were identified in 73.33% of the dogs; mean measure of the smallest diameter was 4.71mm with a standard deviation of 2.61mm and a minimum value of 1mm, and a maximum value of 8mm. From 14 observed lymph nodes 85.71% were isodense when compared with musculature and 14.28% were hypodense. The results show that it is possible to visualize axillary and mediastinal lymph nodes in adult clinically sound Rottweilers with CT using a slice thickness and interval of 10mm. The smallest diameter of the axillary and mediastinal lymph nodes not surpassed 7mm and 8mm respectively. Their attenuations were equal or smaller than that of musculature in the post contrast scan.
                                
Resumo:
The Shadow Moiré fringe patterns are level lines of equal depth generated by interference between a master grid and its shadow projected on the surface. In simplistic approach, the minimum error is about the order of the master grid pitch, that is, always larger than 0,1 mm, resulting in an experimental technique of low precision. The use of a phase shift increases the accuracy of the Shadow Moiré technique. The current work uses the phase shifting method to determine the surfaces three-dimensional shape using isothamic fringe patterns and digital image processing. The current study presents the method and applies it to images obtained by simulation for error evaluation, as well as to a buckled plate, obtaining excellent results. The method hands itself particularly useful to decrease the errors in the interpretation of the Moiré fringes that can adversely affect the calculations of displacements in pieces containing many concave and convex regions in relatively small areas.
                                
Resumo:
Some basic topics concerned with the extraction of textural and geometric information from cell nucleus images as well as description and characterization of chromatin supraorganization and consequent classification of nuclear phenotypes are presented.
                                
Resumo:
We describe a low-cost, high quality device capable of monitoring indirect activity by detecting touch-release events on a conducting surface, i.e., the animal's cage cover. In addition to the detecting sensor itself, the system includes an IBM PC interface for prompt data storage. The hardware/software design, while serving for other purposes, is used to record the circadian activity rhythm pattern of rats with time in an automated computerized fashion using minimal cost computer equipment (IBM PC XT). Once the sensor detects a touch-release action of the rat in the upper portion of the cage, the interface sends a command to the PC which records the time (hours-minutes-seconds) when the activity occurred. As a result, the computer builds up several files (one per detector/sensor) containing a time list of all recorded events. Data can be visualized in terms of actograms, indicating the number of detections per hour, and analyzed by mathematical tools such as Fast Fourier Transform (FFT) or cosinor. In order to demonstrate method validation, an experiment was conducted on 8 Wistar rats under 12/12-h light/dark cycle conditions (lights on at 7:00 a.m.). Results show a biological validation of the method since it detected the presence of circadian activity rhythm patterns in the behavior of the rats
                                
Resumo:
The aim of the present study was to measure full epidermal thickness, stratum corneum thickness, rete length, dermal papilla widening and suprapapillary epidermal thickness in psoriasis patients using a light microscope and computer-supported image analysis. The data obtained were analyzed in terms of patient age, type of psoriasis, total body surface area involvement, scalp and nail involvement, duration of psoriasis, and family history of the disease. The study was conducted on 64 patients and 57 controls whose skin biopsies were examined by light microscopy. The acquired microscopic images were transferred to a computer and measurements were made using image analysis. The skin biopsies, taken from different body areas, were examined for different parameters such as epidermal, corneal and suprapapillary epidermal thickness. The most prominent increase in thickness was detected in the palmar region. Corneal thickness was more pronounced in patients with scalp involvement than in patients without scalp involvement (t = -2.651, P = 0.008). The most prominent increase in rete length was observed in the knees (median: 491 µm, t = 10.117, P = 0.000). The difference in rete length between patients with a positive and a negative family history was significant (t = -3.334, P = 0.03), being 27% greater in psoriasis patients without a family history. The differences in dermal papilla distances among patients were very small. We conclude that microscope-supported thickness measurements provide objective results.
                                
Resumo:
Arterial baroreflex sensitivity estimated by pharmacological impulse stimuli depends on intrinsic signal variability and usually a subjective choice of blood pressure (BP) and heart rate (HR) values. We propose a semi-automatic method to estimate cardiovascular reflex sensitivity to bolus infusions of phenylephrine and nitroprusside. Beat-to-beat BP and HR time series for male Wistar rats (N = 13) were obtained from the digitized signal (sample frequency = 2 kHz) and analyzed by the proposed method (PRM) developed in Matlab language. In the PRM, time series were low-pass filtered with zero-phase distortion (3rd order Butterworth used in the forward and reverse direction) and presented graphically, and parameters were selected interactively. Differences between basal mean values and peak BP (deltaBP) and HR (deltaHR) values after drug infusions were used to calculate baroreflex sensitivity indexes, defined as the deltaHR/deltaBP ratio. The PRM was compared to the method traditionally (TDM) employed by seven independent observers using files for reflex bradycardia (N = 43) and tachycardia (N = 61). Agreement was assessed by Bland and Altman plots. Dispersion among users, measured as the standard deviation, was higher for TDM for reflex bradycardia (0.60 ± 0.46 vs 0.21 ± 0.26 bpm/mmHg for PRM, P < 0.001) and tachycardia (0.83 ± 0.62 vs 0.28 ± 0.28 bpm/mmHg for PRM, P < 0.001). The advantage of the present method is related to its objectivity, since the routine automatically calculates the desired parameters according to previous software instructions. This is an objective, robust and easy-to-use tool for cardiovascular reflex studies.
                                
Resumo:
A long-standing debate in the literature is whether attention can form two or more independent spatial foci in addition to the well-known unique spatial focus. There is evidence that voluntary visual attention divides in space. The possibility that this also occurs for automatic visual attention was investigated here. Thirty-six female volunteers were tested. In each trial, a prime stimulus was presented in the left or right visual hemifield. This stimulus was characterized by the blinking of a superior, middle or inferior ring, the blinking of all these rings, or the blinking of the superior and inferior rings. A target stimulus to which the volunteer should respond with the same side hand or a target stimulus to which she should not respond was presented 100 ms later in a primed location, a location between two primed locations or a location in the contralateral hemifield. Reaction time to the positive target stimulus in a primed location was consistently shorter than reaction time in the horizontally corresponding contralateral location. This attentional effect was significantly smaller or absent when the positive target stimulus appeared in the middle location after the double prime stimulus. These results suggest that automatic visual attention can focus on two separate locations simultaneously, to some extent sparing the region in between.
                                
Resumo:
The loss of brain volume has been used as a marker of tissue destruction and can be used as an index of the progression of neurodegenerative diseases, such as multiple sclerosis. In the present study, we tested a new method for tissue segmentation based on pixel intensity threshold using generalized Tsallis entropy to determine a statistical segmentation parameter for each single class of brain tissue. We compared the performance of this method using a range of different q parameters and found a different optimal q parameter for white matter, gray matter, and cerebrospinal fluid. Our results support the conclusion that the differences in structural correlations and scale invariant similarities present in each tissue class can be accessed by generalized Tsallis entropy, obtaining the intensity limits for these tissue class separations. In order to test this method, we used it for analysis of brain magnetic resonance images of 43 patients and 10 healthy controls matched for gender and age. The values found for the entropic q index were 0.2 for cerebrospinal fluid, 0.1 for white matter and 1.5 for gray matter. With this algorithm, we could detect an annual loss of 0.98% for the patients, in agreement with literature data. Thus, we can conclude that the entropy of Tsallis adds advantages to the process of automatic target segmentation of tissue classes, which had not been demonstrated previously.
 
                    