81 resultados para Alcohol blood tests.
Resumo:
Indirect Immunofluorescence (IFA), Plaque Reduction Neutralization (PRN) and Haemagglutination Inhibition (HI) tests for measles antibodies were carried out in 197 sera obtained from umbilical cord and vaccinated children. The IFA was also applied to blood samples collected with filter paper. IFA results demonstrated that the test is relatively simple to perform, with good reproducibility for different antigen lots. Good correlation was obtained between IFA, PRN and HI antibody titers. Better correlation was demonstrated with IFA and PRN than with HI and PRN tests. Sensitivity of IFA in detecting antibody was less effective than PRN, however more effective than HI using rhesus monkey red blood cells. PRN antibody titers over 100 were detected by IFA but not by HI (9.7% with negative results). IFA may be of considerable practical use and able to substitute HI in Seroepidemiological surveys and to evaluate vaccine efficacy. It also can be simplified by employing filter paper collected samples.
Resumo:
This work reports on the results of double immunodiffusion (ID), counterimmunoelectrophoresis (CIE), complement fixation (CF) and indirect immunofluorescence (IIF) techniques in the serodiagnosis of paracoccidioidomycosis. The study was undertaken on four groups of individuals: 46 patients with untreated paracoccidioidomycosis, 22 patients with other deep mycoses, 30 with other infectious diseases (tuberculosis and cutaneous leishmaniasis) and 47 blood donors as negative controls. Data were obtained using Paracoccidioides brasiliensis antigens, i.e.,a yeast culture filtrate for ID, CIE and CF, and a yeast cell suspension for IIF. The sensitivity, specificity and efficiency values were measured according to GALEN & GAMBINO8.The gel precipitation tests (ID and CIE) showed the greatest sensitivity (91.3 and 95.6%, respectively), maximum specificity (100%) and the highest efficiency values when compared to the CF and IIF tests.
Resumo:
A laboratory study was conducted to test the toxicity of synthetic insecticides added to defibrinated sheep blood kept at room temperature and offered as food to the following triatomine species: Triatoma infestans, Panstrongylus megistus, Triatoma vitticeps, Triatoma pseudomaculata, Triatoma brasiliensis and Rhodnius prolixus. The insecticides used, at a concentration of 1g/l, were: HCH, DDT, Malathion and Trichlorfon, and the lethalithy observed at the end of a 7-day period varied according to the active principle of each. HCH was the most effective by the oral route, killing 100% of the insects, except P. megistus (95.7%) and T. pseudomaculata (94.1%). Trichlorfon killed the insects at rates ranging from 71.8% (T. vitticeps) to 98% (R. prolixus). Malathion was slightly less efficient, killing the insects at rates from 56.8% (T. vitticeps) to 97% (T.brasiliensis). DDT was the least effective, with a killing rate of 10% (T. vitticeps) to 75% (T.brasiliensis). Since the tests were performed at room temperature, we suggest that baits of this type should be tried for the control of triatomines in the field.
Resumo:
Data concerning HCV infection in Central Brazil are rare. Upon testing 2,350 voluntary blood donors from this region, we found anti-HCV prevalence rates of 2.2% by a second generation ELISA and 1.4% after confirmation by a line immunoassay. Antibodies against core, NS4, and NS5 antigens of HCV were detected in 81.8%, 72.7%, and 57.5%, respectively, of the positive samples in the line immunoassay. HCV viremia was present in 76.6% of the anti-HCV-positive blood donors. A relation was observed between PCR positivity and serum reactivity in recognizing different HCV antigens in the line immunoassay. The majority of the positive donors had history of previous parenteral exposure. While the combination of ALT>50 IU/l and anti-HBc positivity do not appear to be good surrogate markers for HCV infection, the use of both ALT anti-HCV tests is indicated in the screening of Brazilian blood donors.
Resumo:
The most frequent form of acquisition of Chagas' disease in endemic areas was the transmission through the feces of contaminated triatominae. However, special attention should be paid in urban areas to transmission by blood transfusion, justifying the compulsory screening of blood donors. Early investigations at blood banks in the town of Londrina, Brazil, demonstrated that the seroprevalence of anti-Trypanosoma cruzi antibodies among blood donors was approximately 7.0% in the fifties9,34. Further studies demonstrated pratically the same seroprevalence until the eighties4,32,41. In an attempt to obtain data about the real dimension of the seropositivity for anti-Trypasonoma cruzi antibodies in the region, the authors carried out a large-scale study on 45,774 serum samples from blood donors of the Hemocentro of Hospital Universitário Regional do Norte do Paraná (HURNP), Universidade Estadual de Londrina. The immunological tests were done at the Division of Clinical Immunology of HURNP from May 1990 to December 1994. The serum samples were studied by the indirect hemagglutination assay (IHA, using kits commercially obtained from EBRAM) and by indirect immunofluorescence (IFI, using kits from LIO SERUM) with anti-human IgG conjugate (LABORCLIN). The results demonstrated that 643 serum samples were positive in both assay corresponding to a seroprevalence of 1.4%, i.e., a significant decrease in anti-Trypanosoma cruzi antibodies in the region in comparison with the previously mentioned rates. Data correlating sex and age of seropositive blood donors are presented, as well as the possible factors that may have contributed to the results observed.
Resumo:
The determination of aminotranferases levels is very useful in the diagnosis of hepatopathies. In recent years, an elevated serum ALT level in blood donors has been associated with an increased risk of post-transfusion hepatitis (PTH). The purpose of the study was to research the factors associated with elevated ALT levels in a cohort of voluntary blood donors and to evaluate the relationship between increased ALT levels and the development of hepatitis C (HCV) infection. 166 volunteer blood donors with elevated ALT at the time of their first donation were studied. All of the donors were questioned about previous hepatopathies, exposure to hepatitis, exposure to chemicals, use of medication or drugs, sexual behaviour, contact with blood or secretions and their intake of alcohol. Every three months, the serum levels of AST, ALT, alkaline phosphatase, gamma glutamyl transpeptidase, cholesterol, triglyceride and glycemia are assessed over a two year follow-up. The serum thyroid hormone levels as well as the presence of auto-antibodies were also measured. Abdominal ultrasound was performed in all patients with persistently elevated ALT or AST levels. A needle biopsy of liver was performed in 9 donors without definite diagnostic after medical investigation. The presence of anti-HCV antibodies in 116 donors were assayed again the first clinical evaluation. At the end of follow-up period (2 years later) 71 donors were tested again for the presence of anti-HCV antibodies. None of donors resulted positive for hepatitis B or hepatitis C markers during the follow-up. Of the 116 donors, 101 (87%) had persistently elevated ALT serum levels during the follow-up. Obesity and alcoholism were the principal conditions related to elevated ALT serum levels in 91/101 (90.1%) donors. Hypertriglyceridemia, hypercholesterolemia, hypothyroidism and diabetes mellitus also were associated with increased ALT levels. Only 1/101 (0.9%) had mild chronic active non A-G viral hepatitis and 3/101 (2.9%) had liver biopsy with non-specific reactive hepatitis. The determination of ALT levels was not useful to detect donors infected with HCV at donation in Brazil, including the initial seronegative anti-HCV phase.
Resumo:
The objective of the present study is to standardize the technical variables for preparation and storage of Plasmodium falciparum and of antigen components extracted with the amphoteric detergent Zwittergent. P. falciparum obtained from in vitro culture was stored at different temperatures and for different periods of time. For each variable, antigen components of the parasite were extracted in the presence or absence of protease inhibitors and submitted or not to later dialysis. Products were stored for 15, 30 and 60 days at different temperatures and immunological activity of each extract was determined by SDS-PAGE and ELISA using positive or negative standard sera for the presence of IgG directed to blood stage antigens of P. falciparum. Antigen extracts obtained from parasites stored at -20oC up to 10 days or at -70oC for 2 months presented the best results, showing well-defined bands on SDS-PAGE and Western blots and presenting absorbance values in ELISA that permitted safe differentiation between positive and negative sera.
Resumo:
The clinical and public health importance of indeterminate results in HIV-1/2 testing is still difficult to evaluate in volunteer blood donors. At Fundação Hemominas, HIV-1/2 ELISA is used as the screening test and, if reactive, is followed by Western blot (WB). We have evaluated 84 blood donors who had repeatedly reactive ELISA tests for HIV-1/2, but indeterminate WB results. Sixteen of the 84 donors (19.0%) had history of sexually transmitted diseases; 18/84 (21.4%) informed receiving or paying for sex; 3/84 (3.6%) had homosexual contact; 2/26 women (7.6%) had past history of multiple illegal abortions and 3/84 (3.6%) had been previously transfused. Four out of 62 donors (6.5%) had positive anti-nuclear factor (Hep2), with titles up to 1:640. Parasitological examination of the stool revealed eggs of S. mansoni in 4/62 (6.4%) donors and other parasites in 8/62 (12.9%). Five (5.9%) of the subjects presented overt seroconversion for HIV-1/2, 43/84 (51.2%) had negative results on the last visit, while 36/84 (42.9%) remained WB indeterminate. Although some conditions could be found associated with the HIV-1/2 indeterminate WB results and many donors had past of risky behavior, the significance of the majority of the results remains to be determined.
Resumo:
Between 1992 and 1997, 790 blood donors with anti-HCV EIA-2 strongly reagent (relationship between the sample optical density/cut-off > 3) detected at the blood bank serological screening, were evaluated in ambulatory environment. They were all negative for Chagas disease, syphilis, hepatitis B (HBsAg) and AIDS. Blood samples were collected at the first ambulatorial evaluation, for hemogram, biochemical tests and new serological tests for HCV (anti-HCV EIA-2). In blood samples of 226 repeatedly reagent anti-HCV EIA-2 blood donors, supplementary "immunoblot" test for HCV (RIBA-2) was used. In 209 donors, the presence of HCV-RNA was investigated by the PCR test. The abdominal ultrasonography was realized in 366 donors. In 269 patients liver biopsy was performed for the histopathological study. The follow-up of blood donors showed that 95.6% were repeatedly EIA-2 reagent, 94% were symptomless and denied any hepatitis history, with only 2% mentioning previous jaundice. In 47% of this population at least one risk factor has been detected for the HCV transmission, the use of intravenous drugs being the main one (27.8%). Blood transfusion was the second factor for HCV transmission (27.2%). Hepatomegaly was detected in 54% of the cases. Splenomegaly and signs of portal hypertension have seldom been found in the physical examination, indicating a low degree of hepatic compromising in HCV. Abdominal ultrasound showed alterations in 65% of the subjects, being the steatosis the most frequent (50%). In 83.5% of the donors submitted to the liver biopsy, the histopathological exam showed the presence of chronic hepatitis, usually classified as active (89%) with mild or moderate grade in most of the cases (99.5%). The histopathological exam of the liver was normal in 1.5% of blood donors. The RIBA-2 test and the HCV-RNA investigation by PCR were positive in respectively 91.6 and 75% of the anti-HCV EIA-2 reagent donors. The HCV-RNA research was positive in 82% of the RIBA-2 positive subjects, in 37.5% of the indeterminate RIBA-2 donors and in 9% of the negative RIBA-2 donors. Chronic hepatitis has also been observed in 50% of the histopathological exams of the anti-HCV EIA-2 reagent donors which were indeterminate RIBA-2. Among 18 blood donors with minimal changes histopathological exam 11 (61%) were HCV-RNA positive. Our blood donors anti-HCV reagent generally had clinical, laboratorial and histopathological features observed in patients with chronic HCV hepatitis and a high proportion could be identified in interviews and medical evaluation realized in blood blanks. Generally, these HCV infected donors are identified and discharged only by the serological tests results.
Resumo:
Screening blood donations for anti-HCV antibodies and alanine aminotransferase (ALT) serum levels generally prevents the transmission of hepatitis C virus (HCV) by transfusion. The aim of the present study was to evaluate the efficiency of the enzyme immunoassay (EIA) screening policy in identifying potentially infectious blood donors capable to transmit hepatitis C through blood transfusion. We have used a reverse transcriptase (RT)-nested polymerase chain reaction (PCR) to investigate the presence of HCV-RNA in blood donors. The prevalence of HCV-RNA positive individuals was compared with the recombinant immunoblot assay (RIBA-2) results in order to assess the usefulness of both tests as confirmatory assays. Both tests results were also compared with the EIA-2 OD/C ratio (optical densities of the samples divided by the cut off value). ALT results were expressed as the ALT quotient (qALT), calculated dividing the ALT value of the samples by the maximum normal value (53UI/l) for the method. Donors (n=178) were divided into five groups according to their EIA anti-HCV status and qALT: group A (EIA > or = 3, ALT<1), group B (EIA > or = 3, ALT>1), group C (1<=EIA<3, ALT<1), group D (1<=EIA<3, ALT>1) and group E (EIA<=0.7). HCV sequences were detected by RT-nested PCR, using primers for the most conserved region of viral genome. RIBA-2 was applied to the same samples. In group A (n=6), all samples were positive by RT-nested PCR and RIBA-2. Among 124 samples in group B, 120 (96.8%) were RIBA-2 positive and 4 (3.2%) were RIBA-2 indeterminate but were seropositive for antigen c22.3. In group B, 109 (87.9%) of the RIBA-2 positive samples were also RT-nested PCR positive, as well as were all RIBA-2 indeterminate samples. In group C, all samples (n=9) were RT-nested PCR negative: 4 (44.4%) were also RIBA-2 negative, 4 (44.4%) were RIBA-2 positive and 1 (11.1%) was RIBA-2 indeterminate. HCV-RNA was detected by RT-nested PCR in 3 (37.5%) out of 8 samples in group D. Only one of them was also RIBA-2 positive, all the others were RIBA-2 indeterminate. All of the group E samples (controls) were RT- nested PCR and RIBA-2 negative. Our study suggests a strong relation between anti-HCV EIA-2 ratio > or = 3 and detectable HCV-RNA by RT-nested PCR. We have also noted that blood donors with RIBA-2 indeterminate presented a high degree of detectable HCV-RNA using RT-nested PCR (75%), especially when the c22.3 band was detected.
Resumo:
This study evaluated the usefulness of the anti-HBc, hepatitis C virus antibodies (anti-HCV), human T cell lymphotropic virus I and II antibodies (anti-HTLV I/II), serologic tests for syphilis, and surface antigen of hepatitis B virus (HBsAg) as surrogate markers for the risk for HIV infection in 80,284 serum samples from blood donors from the Blood Bank of "Hospital Universitário Regional Norte do Paraná", Londrina, Paraná State, Brazil, analyzed from July 1994 to April 2001. Among 39 blood donors with positive serology for HIV, 12 (30.8%) were anti-HBc positive, 10 (25.6%) for anti-HCV, 1 (2.6%) for anti-HTLV I/I, 1 (2.6%) was positive for syphilis, and 1 (2.6%) for HBsAg. Among the donors with negative serology for HIV, these markers were detected in 8,407 (10.5%), 441 (0.5%), 189 (0.2%), 464 (0.6%), and 473 (0.6%) samples, respectively. The difference was statistically significant (p < 0.001) for anti-HBc and anti-HCV. Although the predictive positive value for these surrogate markers were low for HIV infection, the results confirmed the anti-HBc and anti-HCV as useful surrogate markers for HIV infection thus reinforcing the maintenance of them in the screening for blood donors contributing to the prevention of the small number of cases in which HIV is still transmitted by transfusion.
Resumo:
This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.
Resumo:
In order to assess the potential risk of anti-HBc-positive blood donors for post-transfusional hepatitis and to investigate whether other HBV serological markers are capable of identifying the presence of the virus, 1000 first-time blood donors were enrolled between June and July 1997. These donors were screened using routine Brazilian blood center tests (HIV 1 and 2, HTLV 1 and 2, Chagas disease, Syphilis, HCV, HBsAg, anti-HBc and ALT ). The 120 (12%) found to be anti-HBc-positive underwent further tests: HBe, anti-HBe, anti-HBs and HBV-DNA by PCR. Ten cases were HBsAg positive and all were HBV-DNA positive by PCR. Three HBsAg-negative donors were HBV-DNA-positive. Two HBV-DNA-positive donors were also anti-HBs-positive. All the HBV-positive donors had at least one HBV marker other than anti-HBc. Anti-HBc is an important cause of blood rejection. Testing for HBsAg alone is not fully protective and anti-HBc remains necessary as a screening test. The presence of anti-HBs is not always indicative of absence of the virus. The addition of other HBV serological markers could represent an alternative in predicting the presence of the virus when compared with PCR. It is recommended that other studies should be carried out to confirm this finding.
Resumo:
Human Immunodeficiency Vírus Type 1 and 2 antibodies detection was performed in 457 dried whole blood spots samples (S&S 903). Q-Preven HIV 1+2 was the screening test used. The results were compared with the gold standard serum tests by ELISA (Cobas Core e Axsym HIV1/2 gO) and imunofluorescence was the definitive confirmatory test. The samples were obtained from the Hospital Nossa Senhora da Conceição in Porto Alegre, RS - Brazil, through whole blood transfer to filter paper card and sent to Caxias do Sul, RS - Brazil where the tests were performed. The dried whole blood spot stability was evaluated with two different panels. The first one was composed of five negative and five positive samples stored at room temperature, 4 ºC, -20 ºC and -70 ºC, while the second was composed of two negative and three positive samples stored at 37 ºC (humidity <50%). Each sample was screened every week for six weeks. These measurement results didn't show variation during the study period. The detected sensibility was 100%, specificity was 99.6%, the positive predictive value was 99.5% and negative predictive values were 100%. The results demonstrated high performance characteristics, opening a new perspective of dried whole blood spot utilization in HIV screening diagnosis.
Resumo:
The seroprevalence and geographic distribution of HTLV-1/2 among blood donors are extremely important to transfusion services. We evaluated the seroprevalence of HTLV-1/2 infection among first-time blood donor candidates in Ribeirão Preto city and region. From January 2000 to December 2010, 1,038,489 blood donations were obtained and 301,470 were first-time blood donations. All samples were screened with serological tests for HTLV-1/2 using enzyme immunoassay (EIA). In addition, the frequency of coinfection with hepatitis B virus (HBV), hepatitis C virus (HCV), human immunodeficiency virus (HIV), Chagas disease (CD) and syphilis was also determined. In-house PCR was used as confirmatory test for HTLV-1/2. A total of 296 (0.1%) first-time donors were serologically reactive for HTLV-1/2. Confirmatory PCR of 63 samples showed that 28 were HTLV-1 positive, 13 HTLV-2 positive, 19 negative and three indeterminate. Regarding HTLV coinfection rates, the most prevalent was with HBV (51.3%) and HCV (35.9%), but coinfection with HIV, CD and syphilis was also detected. The real number of HTLV-infected individual and coinfection rate in the population is underestimated and epidemiological studies like ours are very informative.