47 resultados para 3D ultrasonography
Resumo:
Este trabalho teve como objetivo indicar algumas possíveis manipulações ecofisiológicas, com base em experimentos de arquitetura de plantas. Plantas de erva-mate, seringueira e videira foram caracterizadas no campo e no laboratório, e suas maquetes 3D foram reconstruídas com os programas V-Plants e PlantGLViewer. Indicações sobre a análise de crescimento e impactos ambientais, com a aplicação de diversas simulações, foram discutidas.
Resumo:
The objective of this work was to build mock-ups of complete yerba mate plants in several stages of development, using the InterpolMate software, and to compute photosynthesis on the interpolated structure. The mock-ups of yerba-mate were first built in the VPlants software for three growth stages. Male and female plants grown in two contrasting environments (monoculture and forest understory) were considered. To model the dynamic 3D architecture of yerba-mate plants during the biennial growth interval between two subsequent prunings, data sets of branch development collected in 38 dates were used. The estimated values obtained from the mock-ups, including leaf photosynthesis and sexual dimorphism, are very close to those observed in the field. However, this similarity was limited to reconstructions that included growth units from original data sets. The modeling of growth dynamics enables the estimation of photosynthesis for the entire yerba mate plant, which is not easily measurable in the field. The InterpolMate software is efficient for building yerba mate mock-ups.
Resumo:
OBJETIVO: Reportar resultados de tratamentos do câncer de próstata com radioterapia conformada 3D realizados em uma única instituição. MATERIAIS E MÉTODOS: De julho de 1997 a janeiro de 2002, 285 pacientes consecutivos com câncer de próstata foram submetidos a radioterapia conformada 3D com dose mediana de 7.920 cGy na próstata e analisados retrospectivamente. A distribuição segundo o grupo de risco foi a seguinte: baixo risco - 95 (33,7%); risco intermediário - 66 (23,4%); alto risco - 121 (42,9%) pacientes. RESULTADOS: Em seguimento mediano de 53,6 meses (3,6-95,3 meses), sobrevidas atuariais global, causa específica, livre de metástases a distância e livre de recidiva bioquímica em cinco anos foram de 85,1%, 97,0%, 94,2% e 75,8%, respectivamente. Sobrevidas atuariais livre de toxicidade retal e urinária tardias em cinco anos foram de 96,4% e 91,1%, respectivamente. Ressecção transuretral pré-radioterapia conformada 3D e doses > 70 Gy em 30% do volume da bexiga implicaram maior toxicidade urinária tardia grau 2-3 em cinco anos (p = 0,0002 e p = 0,0264, respectivamente). CONCLUSÃO: A primeira experiência relatada de radioterapia conformada 3D no Brasil permitiu altas doses de radiação, com toxicidades retal e urinária aceitáveis. A existência de ressecção transuretral de próstata pré-radioterapia conformada 3D pode sinalizar maior risco de toxicidade urinária tardia grau 2-3 após irradiação. Restrição da dose < 70 Gy em 30% do volume da bexiga à tomografia de planejamento pode reduzir complicações urinárias tardias.
Resumo:
Objective To compare the capacity of mammography, sonoelastography, B-mode ultrasonography and histological analysis to differentiate benign from malignant breast lesions. Materials and Methods A total of 12 histopathologically confirmed breast lesions were documented. The lesions were assessed by means of mammography, B-mode ultrasonography and sonoelastography, and histopathological analysis was utilized as a gold standard. Sensitivity and specificity were calculated. A receiver operating characteristic (ROC) curve was constructed to evaluate the diagnostic performance of the mentioned techniques. Results Sensitivity and specificity in the differentiation between benign and malignant lesions were respectively 100% and 50% for mammography, 100% and 71% for B-mode ultrasonography, and 67% and 83% for sonoelastography. The area under the ROC curve was calculated for the three imaging modalities and corresponded to 0.792 for mammography, 0.847 for B-mode ultrasonography, and 0.806 for sonoelastography. Conclusion Sonoelastography demonstrated higher specificity and lower sensitivity as compared with mammography and B-mode ultrasonography. On the other hand, B-mode ultrasonography had the largest area under the ROC curve. Sonoelastography has demonstrated to be a promising technique to detect and evaluate breast lesions, and could potentially reduce the number of unnecessary biopsies.
Resumo:
Objective To evaluate the sonographic measurement of subcutaneous and visceral fat in correlation with the grade of hepatic steatosis. Materials and Methods In the period from October 2012 to January 2013, 365 patients were evaluated. The subcutaneous and visceral fat thicknesses were measured with a convex, 3–4 MHz transducer transversely placed 1 cm above the umbilical scar. The distance between the internal aspect of the abdominal rectus muscle and the posterior aortic wall in the abdominal midline was considered for measurement of the visceral fat. Increased liver echogenicity, blurring of vascular margins and increased acoustic attenuation were the parameters considered in the quantification of hepatic steatosis. Results Steatosis was found in 38% of the study sample. In the detection of moderate to severe steatosis, the area under the ROC curve was 0.96 for women and 0.99 for men, indicating cut-off values for visceral fat thickness of 9 cm and 10 cm, respectively. Conclusion The present study evidenced the correlation between steatosis and visceral fat thickness and suggested values for visceral fat thickness to allow the differentiation of normality from risk for steatohepatitis.
Resumo:
Objective To investigate superior mesenteric artery flow measurement by Doppler ultrasonography as a means of characterizing inflammatory activity in Crohn's disease. Materials and Methods Forty patients were examined and divided into two groups – disease activity and remission – according to their Crohn's disease activity index score. Mean superior mesenteric artery flow volume was calculated for each group and correlated with Crohn's disease activity index score. Results The mean superior mesenteric artery flow volume was significantly greater in the patients with active disease (626 ml/min ± 236 × 376 ml/min ± 190; p = 0.001). As a cut off corresponding to 500 ml/min was utilized, the superior mesenteric artery flow volume demonstrated sensitivity of 83% and specificity of 82% for the diagnosis of Crohn's disease activity. Conclusion The present results suggest that patients with active Crohn's disease have increased superior mesenteric artery flow volume as compared with patients in remission. Superior mesenteric artery flow measurement had a good performance in the assessment of disease activity in this study sample.
Resumo:
Beckwith-Wiedemann syndrome is a genetic syndrome characterized by macroglossia, omphalocele, fetal gigantism and neonatal hypoglycemia. The authors report a case of Beckwith-Wiedemann syndrome diagnosed in a 32-year-old primigravida in whom two-dimensional ultrasonography revealed the presence of abdominal wall cyst, macroglossia and polycystic kidneys. Three-dimensional ultrasonography in rendering mode was of great importance to confirm the previous two-dimensional ultrasonography findings.
Resumo:
Fetal development is studied since the advent of two-dimensional ultrasonography. However, a detailed assessment of structures and surfaces improved with three-dimensional ultrasonography. Currently, it is possible to identify embryonic components and fetal parts with greater detail, at all pregnancy trimesters, using the HD live software, where the images gain realistic features by means of appropriate control of lighting and shadowing effects. In the present study, the authors utilized this resource to follow-up, by means of images, the development of a normal pregnancy along all trimesters.
Resumo:
AbstractThe present essay is aimed at getting the radiologist familiar with the basic histological skin structure, allowing for a better correlation with sonographic findings. A high-frequency (22 MHz) ultrasonography apparatus was utilized in the present study. The histological analysis was performed after the skin specimens fixation with formalin, inclusion in paraffin blocks and subsequent staining with hematoxylin-eosin. The authors present a literature review showing the relationship between sonographic and histological findings in normal cutaneous tissue, and discuss the technique for a better performance of the sonographic scan. High-frequency ultrasonography is an excellent tool for the diagnosis of different skin conditions. However, as this method is operator-dependent, it is crucial to understand the normal skin structure as well as the correlation between histological and sonographic findings.
Resumo:
Abstract Objective: To compare the diagnostic performance of the three-dimensional turbo spin-echo (3D TSE) magnetic resonance imaging (MRI) technique with the performance of the standard two-dimensional turbo spin-echo (2D TSE) protocol at 1.5 T, in the detection of meniscal and ligament tears. Materials and Methods: Thirty-eight patients were imaged twice, first with a standard multiplanar 2D TSE MR technique, and then with a 3D TSE technique, both in the same 1.5 T MRI scanner. The patients underwent knee arthroscopy within the first three days after the MRI. Using arthroscopy as the reference standard, we determined the diagnostic performance and agreement. Results: For detecting anterior cruciate ligament tears, the 3D TSE and routine 2D TSE techniques showed similar values for sensitivity (93% and 93%, respectively) and specificity (80% and 85%, respectively). For detecting medial meniscal tears, the two techniques also had similar sensitivity (85% and 83%, respectively) and specificity (68% and 71%, respectively). In addition, for detecting lateral meniscal tears, the two techniques had similar sensitivity (58% and 54%, respectively) and specificity (82% and 92%, respectively). There was a substantial to almost perfect intraobserver and interobserver agreement when comparing the readings for both techniques. Conclusion: The 3D TSE technique has a diagnostic performance similar to that of the routine 2D TSE protocol for detecting meniscal and anterior cruciate ligament tears at 1.5 T, with the advantage of faster acquisition.
Resumo:
A new model for the H2 antagonists binding site is postulated based on adsorption coefficient values of sixteen antagonists, in the affinities constants of the primary and secondary binding sites, and in the chemical characterization of these sites by 3D-QSAR. All study compounds are in the extended conformation and deprotonated form. The lateral validation of the QSARs, CoMFA analysis, affinity constants and chemical similarity data suggest that the antagonists block the proton pump in the H2 receptor interacting with two tyrosines - one in the helix 5, and other in the helix 6.