362 resultados para Orlando Costas


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and rapid conductometric method for captopril determination using copper(II) sulphate solution as titrant was developed. The method was based on the chemical reaction between captopril and Cu(II) ions yielding a precipitate. The conductance of the solution was monitored as a function of the added volume of titrant. The method was applied with success for captopril determination in three pharmaceutical formulations. The relative standard deviation for six successive measurements was smaller than 0.5%. Recovery values from three samples, ranging from 97.7 to 103%, were obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we describe both a chromatographic purification procedure and a spot test for the enzyme peroxidase (POD: EC 1.11.1.7). The enzyme was obtained from crude extracts of sweet potatoes and the chromatographic enzyme purification procedure resulted in several fractions. Therefore a simple, fast and economic spot test for monitoring peroxidase during the purification procedure was developed. The spot test is based on the reaction of hydrogen peroxide and guaiacol, which is catalyzed by the presence of peroxidase yielding the colored tetraguaiacol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of square-wave voltammetry in conjunction with a cathodically pre-treated diamond electrode for the analytical determination of sodium cyclamate is described. The samples were analyzed as received in a 0.5 mol L-1 H2SO4 solution in the concentration range from 5.0 × 10-5 mol L-1 to 4.1 × 10-4 mol L-1, with a detection limit of 4.8 × 10-6 mol L-1. The RSD was smaller than 1.2 % and the proposed method was applied with success in the determination of sodium cyclamate in several dietary products.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work was developed a method for the determination of saccharin in dietary products by a biamperometric titration, using two silver electrodes as working electrodes and silver nitrate as titrant. It were used products as juices (light) and sweeteners with saccharin in concentrations ranged from 8.73 x 10-5 mol L-1 to 1.0 x 10-2 mol L-1, and the results were in close agreement with those data found using a HPLC method at a confidence level of 95%. The main advantages of the proposed method are its simplicity, rapid and low cost.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A multicommuted method for determination of chlorine in water samples using a 100-cm cell was developed. In this method, orto-Tolidine reacts with chlorine and the product was monitored at 438 nm. The analytical curve for chlorine was linear in concentration range from 1.34x10-6 to 2.01x10-5 mol L-1 with a detection limit of 9.40x10-8 mol L-1. A sampling rate of 45 h-1and a RSD of 1.0 % (n = 15) were obtained. The method was applied with success for chlorine determination in six water samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Salix martiana Leyb. is an endemic species from the Amazon river floodplain areas (varzeas), of the State of Amazonas. Stems and leaves were extracted with dichloromethane, methanol and hydro-alcohol and these extracts were fractionated by using conventional chromatographic techniques. The major substances isolated, salicin and trichocarposide (6-0-p-coumaroyl salicin), were determined through analyses of NMR 1D (¹H and 13C) and NMR 2D (gHSQC and gHMBC). These compounds were isolated for the first time in Salix martiana Leyb. (Salicaceae). The percentage of these compounds in S. martiana is very high. The extracts were analyzed for their DPPH antioxidant capacity and the methanolic from the leaves and the hydro-alcoholic from the stems were the more active.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biosensors based on laccase immobilized on microparticles of chitosan crosslinked with tripolyphosphate (biosensor I) and glyoxal (biosensor II) obtained by spray drying for the determinations of rutin in pharmaceutical formulations were developed. Under optimized operational conditions (pH 4.0, frequency of 30 Hz, pulse amplitude of 40 mV and scan increment of 2.0 mV) two analytical curves were obtained for both biosensors showing a detection limit of 6.2x10-8 mol L-1 for biosensor (I) and 2.0x10-8 mol L-1 for biosensor (II). The recovery of rutin from pharmaceutical sample ranged from 90.7 to 105.0% and the lifetime of these biosensors were 4 months (at least 400 determinations).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow injection chemiluminescence method for the determination of paracetamol in pharmaceutical formulations is described. It is based on the consumption of the sodium hypochlorite by paracetamol and decreases of the analytical signal. The analytical curve was linear in the paracetamol concentration range from 5.0 x 10-6 to 5.0 x 10-5 mol L-1, with a detection limit of 1.8 x 10-6 mol L-1. The RSDs were 2.0 and 1.2% respectively for 2.0 x 10-5 and 4.0 x 10-5 mol L-1 paracetamol solutions (n = 10) and a sampling frequency of 180 h-1 was obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple, precise, rapid and low-cost conductometric titration method for the determination of metformin hydrochloride (MET) in pharmaceuticals using silver nitrate as titrant is proposed. The method was based on the chemical reaction between the chloride of metformin hydrochloride molecule and Ag(I) ions, yielding the precipitate AgCl(s). The method was applied for MET determination in three pharmaceuticals and the obtained results with proposed method were in close agreement with those results obtained using an official method of the British Pharmacopoeia, at a 95% confidence level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple, accurate and precise flow-injection turbidimetric procedure for the determination of fluoxetine hydrochloride in pharmaceutical formulations is reported. The procedure is based on the precipitation of chloride of fluoxetine hydrochloride with silver nitrate solution and the yielded insoluble AgCl(s) was monitored at 420 nm. The analytical curve was linear in the fluoxetine hydrochloride concentration range 3.0 x 10-5 - 5.0 x 10-4 mol L-1 with a detection limit of 10 µmol L-1 and, a sample throughout of 60 h-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method employing chitosan as complexant agent in the removal of copper(II) ions generally present in the Brazilian cachaça samples is herein proposed. The efficiency of this method is attributed to its high capacity of metal cations adsorption, mainly due to presence of hydroxyl and amine groups that can serve as chelating sites. The removal of copper(II) ions from this alcoholic beverage was efficient employing either in column and batch system. The analysis were carried out employing the flame atomic absorption spectrometry and the remaining copper(II) concentrations in the treated cachaça were lower than LOD of FAAS technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This review reports the use of solid amalgam electrodes in the electroanalytical determination of organic and inorganic compounds. The different types of amalgam electrodes are presented, and attention is paid to solid amalgam electrode, and here is presented details about the pre-treatment for activation and renovation and also possible modifications in its surface. The wide potential range, higher signal-to-noise ratio, mechanical stability enabling their application in flowing systems, and principally their resistance toward passivation, indicate that the solid amalgam electrodes are environmentally friendly alternatives to mercury electrodes, without loss in the sensitivity and reproducibility in voltammetric responses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A factorial design applied in a voltammetric stripping method for the measurement of Ag(I) in natural water is described. The procedure is based on the effective pre-concentration of silver ions on electrode surface. The calibration graph was linear in the silver concentration range from 7.92 x 10"7 to 1.07 x 10"5 mol L"1 with a detection limit of 3.81 x 10-7 mol L-1. The determination of Ag(I) in natural water samples was carried out satisfactory with the proposed electrode.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study reports on the construction of a turbidimeter employing light emitting diodes as radiation source at a wavelength of 405 nm, a photodiode as detector, a temperature sensor and a microcontroller used for data acquisition and processing. The turbidimeter was applied to determine sulfate concentrations in natural water employing barium chloride as reagent. Potential interferences and recovery studies were performed and an interference of 3.5 % and a recovery between 97.8 and 108 % were estimated. The analytical performance of in situ turbidimeter for the determination of sulfate was evaluated and compared with two commercial spectrophotometers and a good agreement was obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction of a low cost mini sensor containing a bismuth-film electrode (BiFE), as work electrode, a silver electrode as pseudo reference electrode, and copper as counter electrode is proposed. The application of this mini sensor using a low cost electrochemical cell for in loco voltammetric determinations of inorganic and organic analytes is also described.