332 resultados para IgG avidity test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The course of human Leishmania chagasi infections appears to be determined by the balance between type 1 (T1) CD4+ and CD8+ T suppressor (Ts) cell activities. Skin test positive adults living in hyperendemic areas who have no history of visceral leishmaniasis (VL) have T1 CD4+ T cell immunodominant responses against L. chagasi. The cytokines they secrete during anti-leishmania responses are a probable source of cytokines which inhibit the CD8+ Ts cells associated with VL. The ability of supernatants generated from peripheral blood mononuclear cells derived from skin test positive adults to reverse immune responses which appear to be mediated by CD8+ Ts cells was assessed in three sets of screening assays. The supernatants displayed three candidate factors. One, which could be explained by Leishmania antigens in the supernatant, decreased high endogenous IL-10 secretion characteristic of one class of VL patients. A second activity decreased high endogenous proliferation characteristic of the same class of patients without decreasing antigen specific proliferation. The third activity inhibited or killed CD8+ T cells but not CD4+ T cells. These activities might be useful in treating VL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Philander opossum and Didelphis marsupialis considered the most ancient mammals and an evolutionary success, maintain parasitism by Trypanosoma cruzi without developing any apparent disease or important tissue lesion. In order to elucidate this well-balanced interaction, we decided to compare the humoral immune response kinetics of the two didelphids naturally and experimentally infected with T. cruzi and immunized by different schedules of parasite antigens, employing an indirect fluorescence antibody test (IFAT). Both didelphids responded with high serological titers to different immunization routes, while the earliest response occurred with the intradermic route. Serological titers of naturally infected P. opossum showed a significant individual variation, while those of D. marsupialis remained stable during the entire follow-up period. The serological titers of the experimentally infected animals varied according to the inoculated strain. Our data suggest that (1) IFAT was sensitive for follow-up of P. opossum in natural and experimental T. cruzi infections; (2) both P. opossum and D. marsupialis are able to mount an efficient humoral immune response as compared to placental mammals; (3) experimentally infected P. opossum and D. marsupialis present distinct patterns of infection, depending on the subpopulation of T. cruzi, (4) the differences observed in the humoral immune responses between P. opossum and D. marsupialis, probably, reflect distinct strategies selected by these animals during their coevolution with T. cruzi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the presence of specific IgG antibodies to Borrelia burgdorferi in patients with clinical manifestations associated with Lyme borreliosis in Cali, Colombia, 20 serum samples from patients with dermatologic signs, one cerebrospinal fluid (CSF) sample from a patient with chronic neurologic and arthritic manifestations, and twelve serum samples from individuals without clinical signs associated with Lyme borreliosis were analyzed by IgG Western blot. The results were interpreted following the recommendations of the Centers for Diseases Control and Prevention (CDC) for IgG Western blots. Four samples fulfilled the CDC criteria: two serum specimens from patients with morphea (localized scleroderma), the CSF from the patient with neurologic and arthritic manifestations, and one of the controls. Interpretation of positive serology for Lyme disease in non-endemic countries must be cautious. However these results suggest that the putative "Lyme-like" disease may correlate with positivity on Western blots, thus raising the possibility that a spirochete genospecies distinct from B. burgdorferi sensu stricto, or a Borrelia species other than B. burgdorferi sensu lato is the causative agent. Future work will focus on a survey of the local tick and rodent population for evidence of spirochete species that could be incriminated as the etiologic agent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the frequency of specific anti-Toxoplasma IgM, IgA and IgE antibodies in serum of 28 immunocompetent Colombian patients, selected by ophthalmologists and with lesions that were compatible with ocular toxoplasmosis. Patients were classified in three groups: (i) group 1 consisted of ten patients with a first episode; (ii) group 2, with seven patients with a recurrence and (iii) group 3, consisted of eleven patients with chronic chorioretinal lesion without uveitis. We found that 10/28 (35%) of Colombian patients with ocular toxoplasmosis possessed at least one serological marker for Toxoplasma infection different from IgG. In group 1 (first episode), we found simultaneous presence of specific IgM plus IgA plus IgE in 1/10 (10%). In group 2 (recurrences) in 1/7 (14%) we found IgM and IgA test positives and in 1/7 (14%) we found IgM and IgE tests positives. In group 3 (toxoplasmic chorioretinal scar) the IgA serological test was positive in 2/11 (18%). These results show that serum IgM or IgA or IgE can be present during recurrences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The susceptibility patterns of 108 Campylobacter jejuni subsp. jejuni clinical strains, to six antimicrobial agents was determined by using the E-test and the double dilution agar methods. Using both metods, no strain was found to be resistant to ciprofloxacin, erythromycin and gentamicin, but two (1.8%) were resistant to tetracycline and all to aztreonam. Seven (6.5%) strains were resistant to ampicillin by the E-test and five (4.6%) by the double dilution agar method and by both meyhods. No great discrepancies were observed between both methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was undertaken to evaluate an enzyme immunoassay (EIA) for hepatitis C virus antibody detection (anti-HCV), using just one antigen. Anti-HCV EIA was designed to detect anti-HCV IgG using on the solid-phase a recombinant C22 antigen localized at the N-terminal end of the core region of HCV genome, produced by BioMérieux. The serum samples diluted in phosphate buffer saline were added to wells coated with the C22, and incubated. After washings, the wells were loaded with conjugated anti-IgG, and read in a microtiter plate reader (492 nm). Serum samples of 145 patients were divided in two groups: a control group of 39 patients with non-C hepatitis (10 acute hepatitis A, 10 acute hepatitis B, 9 chronic hepatitis B, and 10 autoimmune hepatitis) and a study group consisting of 106 patients with chronic HCV hepatitis. In the study group all patients had anti-HCV detected by a commercially available EIA (Abbott®), specific for HCV structural and nonstructural polypeptides, alanine aminotransferase elevation or positive serum HCV-RNA detected by nested-PCR. They also had a liver biopsy compatible with chronic hepatitis. The test was positive in 101 of the 106 (95%) sera from patients in the study group and negative in 38 of the 39 (97%) sera from those in the control group, showing an accuracy of 96%. According to these results, our EIA could be used to detect anti-HCV in the serum of patients infected with hepatitis C virus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Angiostrongylus costaricensis may cause intestinal lesions of varied severity when it accidentally infects man in Central and South America. First-stage larvae have never been detected in stools. Therefore, a parasite-specific IgG ELISA was evaluated for the determination of the acute phase of infection. The specificity and the sensitivity of the immunoassay was shown to be 76.2% and 91.1%, respectively. Eight serum samples taken from patients with histopathological diagnosis, at different time points (3 to 15 months) after surgical treatment, showed a sharp and early decline in antibody reactivity. The titration of anti-A. costaricensis antibodies has proved to be a useful method for the diagnosis of acute abdominal angiostrongyliasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the diagnostic performance characteristics of newly developed method, the rapid dipstick test, which provides colorimetric determination by developing antibody to the lactate dehydrogenase enzyme of parasites, with conventional standard thick-blood film examination. For the rapid test, OptiMAL commercial kits were used. The results were also evaluated with clinical findings from patients. The parasites were determined by microscopic examination of thick-blood films from 81 patients with vivax malaria from southeastern Anatolia, Turkey. The OptiMAL test results were found to be negative in five patients who were diagnosed clinically and through thick-film testing as having vivax malaria. There was no false positivity observed with the OptiMAL test. We concluded that this rapid malaria test has a lower level of sensitivity than the classical thick-blood-film test for malaria, but that these methods have equal specificity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Mal de Cadeiras", an enzootic disease caused by Trypanosoma evansi, is one of the most important trypanosomiases in the Brazilian Pantanal region. The disease affects mainly horses, which are widely used in extensive cattle production, an activity of greatest economical significance for the region. The parasite also infects sylvan (coatis and capybaras) and domestic (dogs) animals, respectively considered wild and domestic reservoirs of T. evansi. For a better understanding of the interaction of T. evansi with its rodent host, we evaluated the differences in the specific antibody level patterns and in the parasitic peptides recognition patterns of experimentally infected Wistar rats. The rats experimentally infected with T. evansi isolates obtained from coatis, dogs and horses were submitted to indirect immunofluorescence test (IgM e IgG) and Western blotting. The serological titers for IgM and IgG ranged between 1:40 and 1:160. The most recognized polypeptide profiles were in a range of 17 and 74 kDa. Our data suggest that the humoral immune response in Wistar rats is not sufficient for granting an effective control of T. evansi infections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of anti-Toxoplasma gondii IgM and IgG antibodies was studied in samples of blood serum taken from eighty dogs with nervous symptoms at the Serviço de Enfermidades Infecciosas dos Animais, Faculdade de Medicina Veterinária e Zootecnia, Unesp, Botucatu, São Paulo, Brazil. The frequency of IgG titers were 16 (13.7%), 64 (13.7%), and 256 (5%), and for IgM titers were 16 (7.5%), 64 (15%), and 256 (8.7%). Positive reactions were more frequent in the older animals, males, from a rural environment, in constant contact with small animals, principally birds and rodents. There was a higher frequency of a positive reaction in dogs fed with kitchen food, especially in those fed with raw ingredients. The most common neurological pictures were alterations in consciousness, in movement, and in the hand-cart test. The percentage of reagents with specific IgM antibodies was high, indicating active infections, but the possibility of co-infection with the distemper virus can not be discarded, and this may be a predisposing factor for toxoplasmosis infection, once the distemper virus has a potent immunosupressive action.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Procedures for IgG depletion in visceral leishmaniasis (VL) and schistosomiasis sera using Sepharose-protein G beads also deplete IgE. In this study, the presence of IgG anti-IgE autoantibodies in sera from patients with VL (n = 10), and hepatic-intestinal schistosomiasis (n = 10) and from healthy individuals (n = 10) was investigated. A sandwich ELISA using goat IgG anti-human IgE to capture serum IgE and goat anti-human IgG peroxidase conjugate to demonstrate the binding of IgG to the IgE captured was performed. VL sera had higher titers (p < 0.05) of IgG anti-IgE autoantibodies (OD = 2.01 ± 0.43) than sera from healthy individuals (OD = 1.35 ± 0.16) or persons infected with Schistosoma mansoni (OD = 1.34 ± 0.18). The immunoblotting carried out with eluates from Sepharose-protein G beads used to deplete IgG from these sera and goat anti-human IgE peroxidase conjugate, showed a similar pattern of bands, predominating the 75 kDa epsilon-heavy chain and also polypeptides resulting from physiological enzymatic digestion of IgE. A frequent additional band immediately above 75 kDa was observed only in VL sera.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The detection of rabies antibodies is extremely valuable for epidemiological studies, determination of immune status in man, animals, and for the diagnosis of the disease. Several serological procedures have been described for this purpose. The present study reports a comparison between counterimmunoelectrophoresis test (CIET) and mouse neutralization test (MNT) in the detection of antibodies against rabies virus from 212 serum samples of vaccinated dogs. The agreement between both techniques was 79.7% and a significative association was demonstrated. The correlation coefficients between MNT and the CIET titers was determined considering 88 samples showing positive results in both techniques [CIET = 2 and MNT = 5 (0.13 IU/ml)] and resulted r² = 0.7926 (p < 0.001). The performance of CIET system was technically simple, cheap and rapid, and thereby it could be useful for serological monitoring of dog vaccination campaigns as well as for individual analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the direct-method test of sensitivity to drugs used in the principal tuberculosis treatment regimes, in the Organon Teknika MB/BacT system, we tested 50 sputum samples positive to microscopy taken from patients with pulmonary tuberculosis and with clinical indications for an antibiogram, admitted sequentially for examination during the routine of the reference laboratory. The material was treated v/v with 23% trisodium phosphate solution, incubated for 24 h at 35°C, and neutralized v/v with 20% monosodium phosphate solution. The material was then centrifuged and the sediment inoculated into flasks containing Rifampin - 2 µg/ml, Isoniazid - 0.2 µg/ml, Pyrazinamide - 100 µg/ml, Ethambutol - 2.5 µg/ml, Ethionamide - 1.25 µg/ml, and Streptomycin - 2 µg/ml. The tests were evaluated using the indirect method in the BACTEC 460 TB (Becton Dickinson) system as the gold standard. The results showed that the Rifampin test performed best, i.e., 100% sensitivity at 95% Confidence Interval (82.2-100) and 100% specificity at 95% Confidence Interval (84.5-100), followed by Isoniazid and Pyrazinamide. In this experiment, 92% of the materials showed a final reading in 30 days; this period represents the time for primary isolation as well as the results of the sensitivity profile, and is within Centers for Disease Control and Prevention recommendations regarding time for performance of the antibiogram. The inoculated flasks showed no contamination during the experiment. The MB/BacT is shown to be a reliable, rapid, fully automated nonradiometric system for the tuberculosis antibiogram.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A recombinant-antigen enzyme immunoassay (EIA), BioSCREEN TM anti-Treponema pallidum, was compared favorably with the T. pallidum hemagglutination test, in the detection of specific antibodies in different groups of sera from patients with primary (n = 38), secondary (n = 10), early latent (n = 28) and congenital syphilis (n = 2), patients with leptospirosis ( n= 8), infectious mononucleosis (n = 7), hepatitis (n = 9), diabetes mellitus (n = 11), rheumatoid arthritis (n = 13), leprosy (n = 11), tuberculosis (n = 9), HIV/Aids ( n= 12), systemic lupus erythematosus (n = 4), rheumatic fever (n = 3), old-persons (n = 9), pregnant women (n = 29) and blood donors (n = 164). The coincidence between them was 95.1%. The sensitivity and specificity of the EIA were 93.3% and 95.5%, respectively. Fifteen serum specimens belonging to old-persons, pregnant women, blood donors, and patients with human leptospirosis, hepatitis, diabetes mellitus, tuberculosis and rheumatic fever gave false-positive results by Venereal Disease Research Laboratory and/or Rapid Plasma Reagin. The EIA can be used as alternative method for the serological confirmation of syphilis.