404 resultados para Extração semi-automática


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to standardize the extractive solution of Syzygium cumini. The extractive solution was selected through a full factorial design, considering the extraction method (maceration-5-days, turbo extraction, percolation), extractor solvent (ethanol 50, 70, 96%) and plant material particle size 0.302 mm into a plant:solvent ratio (1:10), using the dried residue and antimicrobial activity determination as evaluation criteria. The tests were performed in triplicate. It appeared that the percolation is the best procedure extractive, and ethanol mixture: water (50:50) the best solvent. ANOVA analysis showed the importance of these parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work evaluated the use of the Hildebrand/Hansen solubility parameters for selection of solvents for extraction of the organochlorine pesticides pp' DDT, pp' DDE, Aldrin and a-Endossulfan from soil using columns packed with Al2O3. The mixtures hexane:dichloromethane (7:3; v/v), hexane:acetonitrile (1:1; v/v), hexane:acetone (1:1; v/v) and pure hexane were chosen as extracting solutions. In the addition and recovery tests, different extraction solutions provided high recoveries percentages (>75%) with coefficients of variation below 15%. The recoveries are in agreement with the Hildebrand/Hansen parameters, demonstrating its applicability in the selection of extracting solution and in the replacement of toxic solvents, as dichloromethane

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This works describes the use of experimental design and surface response methodology for optimization of saponin extraction from Ampelozizyphus amazonicus. For this purpose, a method employing extraction based on maceration assisted by ultrasound technique was utilized. The following factors were studied: extraction length of time and solvent composition. The total saponin was determined by using a gravimetric method and the results expressed by their relative proportion to total crude extract. For the specific condition, 60% hydro-alcoholic solution and 18 minutes extraction length of time has shown the best results. This method can be useful for extraction of substances with biological importance

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work applied a 2² factorial design to the optimization of the extraction of seven elements (calcium, magnesium, potassium, iron, zinc, copper and manganese) in brachiaria leaves, determined by flame atomic absorption spectrometry. The factors sample mass and digestion type were evaluated at two levels: 200/500 mg, and dry/wet, respectively. Principal component analysis allowed simultaneous discrimination of all the significant effects in one biplot. Wet digestion and mass of 200 mg were considered the best conditions. The decrease of 60% in sample mass allowed to save costs and reagents. The method was validated through the estimation of figures of merit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extraction of divalent metals (Mn2+, Ni2+, Co2+ and Cu2+) in the system MSO4 - H2SO4 - H2O - D2EHPA in isoparaffin (17/21) was studied by a thermodynamic model based on chemical equilibria with mass and charge balance equations. The activity coefficients of all solutes in the aqueous phase were calculated by Davies equation. By applying this model, the equilibrium concentrations of solutes were calculated from de concentration of divalent metals and pH. The predicted distribution coefficients for the divalents metals were in good agreement with experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aimed to access the contents and chemical forms and to estimate mobility and availability of cooper and zinc in samples from two soils (Haplortox and Paleudult) previously treated with doses of sewage sludge (SS) and municipal solid waste compost (MSWC), besides a control treatment. Largest percentages of Cu and Zn were determined in the organic matter fraction. Zn showed higher percentages of soluble and exchangeable fractions than Cu. Treatments with SS showed higher potential of Cu and Zn availability. Modifications in soil attributes due to residue application affected metal mobility and availability indexes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes an analytical method for analyzing polychlorinated biphenyls in corn samples using solid phase extraction (SPE) followed by determination by GC-MS. All calibration curves proved linear (r> 0.99). Recoveries ranged between 74.1 and 110.6% with relative standard deviation lower than 20% for all compounds. The limits of quantitation for the method were between 0.025 and 0.1 ng g-1. Of the 51 samples analyzed, PCB 180 showed the highest frequency, being detected in more than 39%, followed by PCB 138, detected in more than 33% of samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes selective molecularly imprinted solid-phase extraction of ttMA from urine samples followed by derivatization and analysis by gas chromatography/mass spectrometry (GC/MS). The analytical calibration curve ranged from 0.3 to 7.0 mg L-1 (r = 0.999) and the limit of quantitation (LOQ) was 0.3 mg L-1. The method was applied for the determination of ttMA in urine samples from smokers and concentrations detected ranged from < LOQ to 1.64 mg L-1. Thus, the proposed method proved adequate for the determination of urinary ttMA in the biomonitoring of occupational exposure to low levels of benzene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study proposes a method for cloud point preconcentration of copper ions at pH 2.0 based on complexes formed with [4,5-dimercapto-1,3-dithyol-2-thionate] and subsequent determination by flame atomic absorption spectrometry (FAAS). Under optimal analytical conditions, the method provided limits of detection of 0.84 and 0.45 µg L-1, by preconcentrating 12.0 and 24.0 mL of sample, respectively. The method was applied for copper determination in water samples, synthetic saliva, guarana powder, tea samples and soft drinks and the accuracy was assessed by analyzing the certified reference materials Dogfish Liver (DOLT-4) and Lobster Hepatopancreas (TORT-2).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the evaluation of extraction strategies for the treatment of medicine samples to determine chromium and nickel by GFAAS. Different approaches for extraction were evaluated and the most efficient involved magnetic stirring. The metals were quantitatively extracted by stirring 0.20 g samples with 25 mL of 2.0 mol L-1 HCl solution for 60 min. The developed method was successfully applied for the determination of Cr and Ni in tablets containing antibiotics and raw materials, with cephalexin and ciprofloxacin as active ingredients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sequential extraction procedure was applied to wheat and soybean seed samples. The total protein content (determined by two distinct methods: Bradford and bicinchoninic acid-BCA) and distribution of Cu, Fe, Mn and Zn in each fraction was determined. The sequential extraction employed four different solutions: water, 0.5 mol L-1 NaCl, ethanol/water (70:30 v v-1) and 0.5 mol L-1 NaOH. For both samples, the highest concentration of metals was observed in those extracts associated with globulin-type proteins using NaCl solution. Regarding protein content, higher levels were obtained using the BCA method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study optimized and validated the liquid-liquid extraction technique with partition at low temperature (LLE-PLT) for identification and quantification of four pesticides (chlorpyrifos, λ-cyhalothrin, permethrin, bifenthrin) in water samples. Analyses were performed by HPLC-UV. The technique was efficient for pesticide recovery with extraction exceeding 86%. Chromatographic response was linear for the four compounds in the 10-45 µg L-1 range, with correlation coefficients greater than 0.99. Limits of detection and quantitation were less than 3.5 µg L-1 and equal to 10 µg L-1, respectively. The proposed method was applied to 29 water samples from the Jaíba Project in northern Minas Gerais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mixture Models can be used in experimental situations involving areas related to food science and chemistry. Some problems of a statistical nature can be found, such as effects of multicollinearity that result in uncertainty in the optimization of a dependent variable. This study proposes the application of the ridge model adapted for mixture planning considering the Kronecker (K-model) and Scheffe (S-Model) methods applied to response surfaces. The method determined the proportions of hexane, acetone and alcohol proportions that resulted in the maximum response of percentage of extracted pequi (Caryocar brasiliense) pulp oil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multiresidue method using HPLC/DAD for the determination of fourteen pesticides in water based on SPE, using SDVB (styrene divynilbenzene copolymer) as adsorbent was validated. Recoveries from 61 to 120%, relative standard deviation between 2 and 15% and detection limits from 0.07 to 0.75 µg L-1 were obtained. It was applied to 66 surface water samples collected in a degraded area at the headwaters of São Lourenço river, Mato Grosso, Brazil. Eight pesticides were detected in concentrations ranging from 0.15 to 35.25 µg L-1. Considering ecotoxicological data, carbendazim and carbofuran may represent a risk to aquatic organisms. These results draw attention to the contamination of this vulnerable degraded area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The convenience of the multivariate optimization of SPME procedures through ANOVA calculated using Doehlert designs has been demonstrated for twelve PCBs in the complex matrix of milk. For this study, the main parameters of the extraction were selected and valued through univariate and multivariate optimization. In addition, the analysis of variance allowed identification of the statistically significant variables in this model: high temperature (95 ºC) and ionic strength (36% m/v) proved significant for all the PCBs while intermediate time (70 min) and low methanol concentration (5% v/v) also contributed to the extraction of the majority of these PCBs.