275 resultados para Hypocentral determination
Resumo:
Through the site-specific management, the precision agriculture brings new techniques for the agricultural sector, as well as a larger detailing of the used methods and increase of the global efficiency of the system. The objective of this work was to analyze two techniques for definition of management zones using soybean yield maps, in a productive area handled with localized fertilization and other with conventional fertilization. The sampling area has 1.74 ha, with 128 plots with site-specific fertilization and 128 plots with conventional fertilization. The productivity data were normalized by two techniques (normalized and standardized equivalent productivity), being later classified in management zones. It can be concluded that the two methods of management zones definition had revealed to be efficient, presenting similarities in the data disposal. Due to the fact that the equivalent standardized productivity uses standard score, it contemplates a better statistics justification.
Resumo:
The present study aimed at evaluating the use of Artificial Neural Network to correlate the values resulting from chemical analyses of samples of coffee with the values of their sensory analyses. The coffee samples used were from the Coffea arabica L., cultivars Acaiá do Cerrado, Topázio, Acaiá 474-19 and Bourbon, collected in the southern region of the state of Minas Gerais. The chemical analyses were carried out for reducing and non-reducing sugars. The quality of the beverage was evaluated by sensory analysis. The Artificial Neural Network method used values from chemical analyses as input variables and values from sensory analysis as output values. The multiple linear regression of sensory analysis values, according to the values from chemical analyses, presented a determination coefficient of 0.3106, while the Artificial Neural Network achieved a level of 80.00% of success in the classification of values from the sensory analysis.
Resumo:
The climate variability between the growth and harvesting of sugar cane is very important because it directly affects yield. The MODIS sensor has characteristics like spatial and temporal resolution that can be applied to monitoring of vegetative vigor variability in the land surface and then, temporal profiles generation. Agro meteorological data from ECMWF model are free and easy to access and have a good representation of reality. In this study, we used the period between sugar cane growth and harvest in the state of Sao Paulo, Brazil, from temporal profiles selecting of NDVI behavior. For each period the precipitation, evapotranspiration, global radiation, length (days) and degree-days were accumulated. The periods were presented in a map format on MODIS spatial resolution of 250 meters. The results showed the spatial variability of climate variables and the relationship to the reality presented by official data.
Resumo:
The Knowledge of the physical properties of agricultural products has great importance for the construction and operation of equipment for drying and storage, to achieve increased efficiency in post-harvest operations. The aim was to determine and analyze the physical properties of crambe fruits during drying at different temperatures. Crambe fruits with an initial moisture content of 0.36 (decimal d.b.) which was reduced by drying at 37.0; 58.8 and 83.5 ºC and relative humidity of 29.4; 11.2 and 3.2%, respectively, to 0.09 ± 1 (decimal d.b.). At different levels of moisture contents (0.36; 0.31; 0.26; 0.21; 0.17; 0.13 and 0.09 decimal d.b.), was evaluated the intergranular porosity, the bulk density, the true density as well as the volumetric shrinkage and the fruit mass. The study was installed by the factorial 3 x 7, and three drying temperatures and seven moisture contents in a randomized design. Data were analyzed using regression. The bulk density and the true density decreases along the drying process; the volumetric shrinkage and the mass increased with lower moisture content and the intergranular porosity decreased sharply with the increasing drying temperature.
Resumo:
ABSTRACT In animal farming, an automatic and precise control of environmental conditions needs information from variables derived from the animals themselves, i.e. they act as biosensors. Rectal temperature (RT) and respiratory rate (RR) are good indicators of thermoregulation in pigs. Since there is a growing concern on animal welfare, the search for alternatives to measure RT has become even more necessary. This research aimed to identify the most adequate body surface areas, on nursery-phase pigs, to take temperature measurements that best represent the correlation of RT and RR. The main experiment was carried out in a climate chamber with five 30-day-old littermate female Landrace x Large White piglets. Temperature conditions inside chamber were varied from 14 °C up to 35.5 °C. The measurements were taken each 30 minutes, over six different skin regions, using a temperature data logger Thermochron iButton® - DS1921G (Tb) and an infrared thermometer (Ti). As shown by the results, the tympanic region is the best one for RT and RR monitoring using an infrared thermometer (TiF). In contrast, when using temperature sensors, the ear (TbE) is preferred to be used for RT predictions and the loin region (TbC) for RR.
Resumo:
Kinosternon scorpioides (Linnaeus, 1766), with its common name of jurará, is a quite variable species of turtles, and many different names have been applied to populations throughout its range. Currently, however, four subspecies are considered valid as K. scorpioides arises from southern Panama over most of northern South America and is found in Ecuador, northern Peru, southern Bolivia, northern Argentina, eastern Guyana and Brazil. Thus, an ultrasonographic and radiographic study was performed in order to describe the morphology and development of eggs of 20 female jurará mud turtles K. scorpioides, from September 2005 to August 2006. In the first month, the ovarian cycle was characterized by absence of vitellogenic follicles, atresic follicles or oviduct eggs. From October 2005 to March 2006 on, ultrasonographic scanning allowed to establish the growing vitellogenic follicles. Vitellogenic follicles were observed with spherical to ovoid shapes, with a surrounding echogenic yolk, a nonechogenic albumin layer, and a high echogenic shell. The oviduct eggs were identified by radiography just 180 days after beginning the experiment, when the shell became enough mineralized to impress the radiographic film. This experiment allowed to obtain by means of the 7.5 MHz linear probe images with adequate resolution and penetration for visualization of follicles. Successive ultrasonographic examinations of 20 K. scorpioides females allowed to access initial stages of vitellogenic follicles and oviduct eggs, and radiographic examination revealed to be an easy technique to assess oviduct eggs and to allow evaluation of egg development in jurarás, from 6 months on.
Resumo:
In this experiment, methods of total fecal collection (TFC) and internal markers (acid-insoluble ash - AIA, crude fiber - CF, and acid-detergent fiber - ADF) were compared for determination of the coefficients of apparent digestibility (CAD) for dry matter (DM), crude protein (CP), ether extract (EE), nitrogen-free extracts (NFE), and gross energy (GE) of commercial feline dry kibble for ocelots (Leopardus pardalis). Six adult animals, weighing 12.45±1.37 kg, gradually received experimental kibble in their usual diet until the beginning of the experiment and were submitted to an adaptation period ten days prior to the collection period. CAD obtained by TFC, AIA, CF, and ADF were, respectively, 73.7, 76.83, 62.01, and 46.03% for dry matter; 81.9, 84.8, 75.8, and 63.8% for crude protein; 85, 86.7, 78.5, and 69.1% for ether extract; 78.52, 79.55, 69.11, and 53.04% for nitrogen-free extracts; and 80.5, 82.2, 71.4, and 58.4% for gross energy. The AIA method showed to be efficient in determining coefficients of apparent digestibility and may contribute to investigations on the digestibility of diets for wild felines. In comparison to the items of ocelot's usual diet, the kibble used in this paper provided an adequate nutritional supply with reduced daily costs per animal.
Resumo:
It is well known that the numerical solutions of incompressible viscous flows are of great importance in Fluid Dynamics. The graphics output capabilities of their computational codes have revolutionized the communication of ideas to the non-specialist public. In general those codes include, in their hydrodynamic features, the visualization of flow streamlines - essentially a form of contour plot showing the line patterns of the flow - and the magnitudes and orientations of their velocity vectors. However, the standard finite element formulation to compute streamlines suffers from the disadvantage of requiring the determination of boundary integrals, leading to cumbersome implementations at the construction of the finite element code. In this article, we introduce an efficient way - via an alternative variational formulation - to determine the streamlines for fluid flows, which does not need the computation of contour integrals. In order to illustrate the good performance of the alternative formulation proposed, we capture the streamlines of three viscous models: Stokes, Navier-Stokes and Viscoelastic flows.
Resumo:
The objective of this study was to optimize and validate the solid-liquid extraction (ESL) technique for determination of picloram residues in soil samples. At the optimization stage, the optimal conditions for extraction of soil samples were determined using univariate analysis. Ratio soil/solution extraction, type and time of agitation, ionic strength and pH of extraction solution were evaluated. Based on the optimized parameters, the following method of extraction and analysis of picloram was developed: weigh 2.00 g of soil dried and sieved through a sieve mesh of 2.0 mm pore, add 20.0 mL of KCl concentration of 0.5 mol L-1, shake the bottle in the vortex for 10 seconds to form suspension and adjust to pH 7.00, with alkaline KOH 0.1 mol L-1. Homogenate the system in a shaker system for 60 minutes and then let it stand for 10 minutes. The bottles are centrifuged for 10 minutes at 3,500 rpm. After the settlement of the soil particles and cleaning of the supernatant extract, an aliquot is withdrawn and analyzed by high performance liquid chromatography. The optimized method was validated by determining the selectivity, linearity, detection and quantification limits, precision and accuracy. The ESL methodology was efficient for analysis of residues of the pesticides studied, with percentages of recovery above 90%. The limits of detection and quantification were 20.0 and 66.0 mg kg-1 soil for the PVA, and 40.0 and 132.0 mg kg-1 soil for the VLA. The coefficients of variation (CV) were equal to 2.32 and 2.69 for PVA and TH soils, respectively. The methodology resulted in low organic solvent consumption and cleaner extracts, as well as no purification steps for chromatographic analysis were required. The parameters evaluated in the validation process indicated that the ESL methodology is efficient for the extraction of picloram residues in soils, with low limits of detection and quantification.
Resumo:
Chlorophylls and carotenoids are the main photosynthetic pigment in plants. In the weeds, the greatest amount of photosynthetic pigments can result in high competitiveness of the species. The aim of this study was to quantify the content of photosynthetic pigments in biotypes of fleabane (Conyza bonariensis) susceptible and resistant to glyphosate, by two different methods, as well as a correlation between chlorophyll content obtained by portable and classical methodology (extractable chlorophyll). An experiment was conducted in greenhouse and laboratory, 2 x 5 factorial scheme, where factor A was equivalent to biotypes of fleabane (resistant and susceptible to glyphosate) and factor B to developmental stages plants (rosette vegetative I, II and III and reproduction). At all stages of development, fleabane plants were evaluated with the portable determiner (chlorophyll content) and then the same leaves were subjected to classical methodology laboratory (extractable pigments). The resistant biotype of fleabane showed higher contents of chlorophyll a, b, and total carotenoids, inferring a greater competitive potential regarding the susceptible population to the herbicide. The portable determiner of chlorophyll showed high correlation with the classical method of determination of photosynthetic pigments, and can thus be used to accurately assess this, saving time and reagents.
Resumo:
This study has aimed to develop a method for simultaneous extraction and determination by liquid chromatography and mass spectrometry (LC-MS/MS) of glyphosate, aminomethylphosphonic acid (AMPA), shikimic acid, quinic acid, phenylalanine, tyrosine and tryptophan. For the joint analysis of these compounds the best conditions of ionization in mass spectrometry and for chromatographic separation of the compounds were selected. Calibration curves and linearity ranges were also determined for each compound. Different extraction systems of the compounds were tested from plant tissues collected from sugarcane (Saccharum officinarum) and eucalyptus (Eucalyptus urophylla platiphylla) plants two days after the glyphosate application at the dose of 720 g a.e. ha-1. The plant material was dried in a forced air circulation drying oven and in a lyophilizer, and subsequently the extractions with acidified water (pH 2.5), acetonitrile-water (50:50) [v/v] and methanol-water (50:50) [v/v] were tested. To verify the recovery of the compounds in the plant matrix with acidified water as an extracting solution, the samples were fortified with a solution containing the mixture of the different analytical standards present so that this one presented the same levels of 50 and 100 μg L-1 of each compound. All experiments were conducted with three replicates. The analytical method developed was efficient for compounds quantifications. The extraction from the samples dried in an oven and using acidified water allowed better extraction levels for all compounds. The recovery levels of the compounds in the fortified samples with known amounts of each compound for both plants samples were rather satisfactory.
Resumo:
The first experiments on sex determination in bees began with Dzierzon, Meves, Nachtsheim, Paulcke, Petrunkewitsch, Manning. Whiting, (1943) found multiple alleles in Bracon xo that are the Rosetta stone of sex determination in Hymenoptera. Whiting also discovered that some species of microhymenoptera do not possess xo sex alleles. Therefore, Hymenoptera apparently presents two types of sex determination superimposed on haplodiploidy. In the panmictic groups hemizygous (xo1, xo2,... xon) and homozygous (xo1xo1, xo2xo2... xonxon) are males while heterozygous (xo1xo2, ... xon-1xon) are females. There is no such series of xon in endogamous Hymenoptera, since the constant elimination of diploid males would be damaging to the population and the mutation of xo to xon would be quickly eliminated. Besides the Whiting hypothesis, four others are discussed. The new hypothesis of genomic imprinting, of Beukeboom, is eliminated since: a) spermatozoa that develop within the egg produce male tissue; b) telitokous parthenogenesis due to the fusion of two haploid cells develop into females; c) last instar larvae treated with juvenile hormone become queens. The Cunha and Kerr hypothesis (female determining genes are totally or partially additive and male determination is totally or partially nonadditive) explains all known cases. The xo is a female determining gene. Sex determination in social bees led to the gradual evolution of two systems of caste determination: one in which queens and workers are similar and males are very different (Apinae), and another in which workers and males are very similar and both very different from the queens (Meliponinae). This second system in stingless bees implies that many of the mutations that improve worker capacities also affect the males that will carry out some activities that in Apis are clearly female ones. Ten of these activities are described.
Resumo:
Baroreflex sensitivity was studied in the same group of conscious rats using vasoactive drugs (phenylephrine and sodium nitroprusside) administered by three different approaches: 1) bolus injection, 2) steady-state (blood pressure (BP) changes produced in steps), 3) ramp infusion (30 s, brief infusion). The heart rate (HR) responses were evaluated by the mean index (mean ratio of all HR changes and mean arterial pressure (MAP) changes), by linear regression and by the logistic method (maximum gain of the sigmoid curve by a logistic function). The experiments were performed on three consecutive days. Basal MAP and resting HR were similar on all days of the study. Bradycardic responses evaluated by the mean index (-1.5 ± 0.2, -2.1 ± 0.2 and -1.6 ± 0.2 bpm/mmHg) and linear regression (-1.8 ± 0.3, -1.4 ± 0.3 and -1.7 ± 0.2 bpm/mmHg) were similar for all three approaches used to change blood pressure. The tachycardic responses to decreases of MAP were similar when evaluated by linear regression (-3.9 ± 0.8, -2.1 ± 0.7 and -3.8 ± 0.4 bpm/mmHg). However, the tachycardic mean index (-3.1 ± 0.4, -6.6 ± 1 and -3.6 ± 0.5 bpm/mmHg) was higher when assessed by the steady-state method. The average gain evaluated by logistic function (-3.5 ± 0.6, -7.6 ± 1.3 and -3.8 ± 0.4 bpm/mmHg) was similar to the reflex tachycardic values, but different from the bradycardic values. Since different ways to change BP may alter the afferent baroreceptor function, the MAP changes obtained during short periods of time (up to 30 s: bolus and ramp infusion) are more appropriate to prevent the acute resetting. Assessment of the baroreflex sensitivity by mean index and linear regression permits a separate analysis of gain for reflex bradycardia and reflex tachycardia. Although two values of baroreflex sensitivity cannot be evaluated by a single symmetric logistic function, this method has the advantage of better comparing the baroreflex sensitivity of animals with different basal blood pressures.
Resumo:
The tripeptide Hip-His-Leu was used to standardize a fluorimetric method to measure tissue angiotensin-converting enzyme (ACE) activity in rats. The fluorescence of the o-phthaldialdehyde-His-Leu adduct was compared in the presence and absence of the homogenate (25 µl) to determine whether the homogenate from different tissues interfered with the fluorimetric determination of the His-Leu product. Only homogenates from lung and renal medulla and cortex showed significantly altered fluorescence intensity. To overcome this problem, the homogenate from these tissues were diluted 10 times with assay buffer. The specificity of the assay was demonstrated by the inhibition of ACE activity with 3 µM enalaprilat (MK-422). There was a linear relationship between product formation and incubation time for up to 90 min for homogenates of renal cortex and medulla and liver, for up to 60 min for ventricles and adrenals and for up to 30 min for the aorta, lung and atrium homogenates. In addition, there was a linear relationship between product formation and the amount of protein in the homogenates within the following range: lung, 30-600 µg; renal cortex and medulla, 40-400 µg; atrium and ventricles, 20-200 µg; adrenal, 20-100 µg; aorta, 5-100 µg; liver, 5-25 µg. No peptidase activity against the His-Leu product (31 nmol), assayed in borate buffer (BB), was detected in the different homogenates except the liver homogenate, which was inhibited by 0.1 mM r-chloromercuribenzoic acid. ACE activity in BB was higher than in phosphate buffer (PB) due, at least in part, to a greater hydrolysis of the His-Leu product in PB. ACE activity of lung increased 20% when BB plus Triton was used. Enzyme activity was stable when the homogenates were stored at -20o or -70oC for at least 30 days. These results indicate a condition whereby ACE activity can be easily and efficiently assayed in rat tissue samples homogenized in BB using a fluorimetric method with Hip-His-Leu as a substrate.
Resumo:
We have developed a system with two epi-illumination sources, a DC-regulated lamp for transillumination and mechanical switches for rapid shift of illumination and detection of defined areas (250-750 µm²) by fluorescence and phosphorescence videomicroscopy. The system permits investigation of standard microvascular parameters, vascular permeability as well as intra- and extravascular PO2 by phosphorescence quenching of Pd-meso-tetra (4-carboxyphenyl) porphine (PORPH). A Pechan prism was used to position a defined region over the photomultiplier and TV camera. In order to validate the system for in vivo use, in vitro tests were performed with probes at concentrations that can be found in microvascular studies. Extensive in vitro evaluations were performed by filling glass capillaries with solutions of various concentrations of FITC-dextran (diluted in blood and in saline) mixed with different amounts of PORPH. Fluorescence intensity and phosphorescence decay were determined for each mixture. FITC-dextran solutions without PORPH and PORPH solutions without FITC-dextran were used as references. Phosphorescence decay curves were relatively unaffected by the presence of FITC-dextran at all concentrations tested (0.1 µg/ml to 5 mg/ml). Likewise, fluorescence determinations were performed in the presence of PORPH (0.05 to 0.5 mg/ml). The system was successfully used to study macromolecular extravasation and PO2 in the rat mesentery circulation under controlled conditions and during ischemia-reperfusion.