656 resultados para Teste ELISA-IgM


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a cheaper an simple in house indirect ELISA that uses the live attenuated VZV vaccine as a coating antigen. The alternative ELISA had an agreement of 94% when compared with a commercial VZV ELISA kit. Moreover, our ELISA proved to be more reliable than the kit when assessing true negative samples. By adding a standard serum, we were able to produce results in international units per millilitre. Also, the addition of an extra step with 8M urea allowed the assessment of VZV IgG avidity without excessive costs. The cost per sample to test VZV IgG was 2.7 times cheaper with our ELISA, allowing the testing of many samples without the burden of production of VZV antigen in the laboratory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to standardize and evaluate dot-Enzyme linked immunosorbent assay (Dot-ELISA), a simple and rapid test for the detection of cysticercus antibodies in the serum for the diagnosis of neurocysticercosis (NCC). The antigen used in the study was a complete homogenate of Cysticercus cellulosae cysts obtained from infected pigs and dotted on to nitrocellulose membrane. Test sera were collected from the patients of NCC, and control sera from patients with other diseases and healthy students and blood donors of the Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER) Hospital, Pondicherry, during a study period from 2001 to 2003. Dot-ELISA detected antibodies in 14 of 25 (56%) in clinically suspected cases of NCC, 13 of 23 (56.5%) in CT/MRI proven cases of NCC and 2 of 25 (8%) each in non-cysticercal CNS infection controls and healthy controls. The test showed a sensitivity of 56.25%, specificity of 92%, positive predictive value of 87.09%, and negative predictive value of 70.76%. Results of the present study shows that the Dot-ELISA as a simple test can be used in the field or poorly equipped laboratories for diagnosis of NCC .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anti-Toxoplasma IgG-avidity was determined in 168 serum samples from IgG- and IgM-positive pregnant women at various times during pregnancy, in order to evaluate the predictive value for risk of mother-to-child transmission in a single sample, taking the limitations of conventional serology into account. The neonatal IgM was considered the serologic marker of transmission. Fluorometric tests for IgG, IgM (immunocapture) and IgG-avidity were performed. Fifty-one of the 128 pregnant women tested gave birth in the hospital and neonatal IgM was obtained. The results showed 32 (62.75%) pregnant women having high avidity, IgM indexes between 0.6 and 2.4, and no infected newborn. Nineteen (37.25%) had low or inconclusive avidity, IgM indexes between 0.6 and 11.9, and five infected newborns and one stillbirth. In two infected newborns and the stillbirth maternal IgM indexes were low and in one infected newborn the only maternal parameter that suggested fetal risk was IgG-avidity. In the present study, IgG-avidity performed in single samples from positive IgM pregnant women helped to determine the risk of transmission at any time during pregnancy, especially when the indexes of the two tests were analysed with respect to gestational age. This model may be less expensive in developing countries where there is a high prevalence of infection than the follow-up of susceptible mothers until childbirth with monthly serology, and it creates a new perspective for the diagnosis of congenital toxoplasmosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sera from 88 patients from Santa Catarina and São Paulo states of Brazil, with epileptic seizures who underwent cerebral computed tomography (CT) were analyzed for the detection of antibodies to T. solium cysticercus by ELISA and Immunoblot (IB) with the following antigens: Taenia solium cysticercus total saline (Tso), Taenia crassiceps cysticercus vesicular fluid (Tcra-vf) and T. crassiceps cysticercus glycoproteins (Tcra-gp). ELISA carried out with Tso, Tcra-vf and Tcra-gp antigens showed 95%, 90% and 80% sensitivities, respectively, and 68%, 85% and 93% specificities, respectively. In the epileptic patients group, ELISA positivity was 30%, 51% and 35% with Tso, Tcra-vf and Tcra-gp antigens respectively. Considering the IB as the confirmatory test, the positivity was 16% (14/88) in the epileptic patients total group and 22% (12/54) in the epileptic patients with positive CT and signals of cysticercosis. We found a significant statistical correlation among ELISA or IB results and the phase of the disease when any antigens were used (p < 0.05). We emphasize the need to introduce in the laboratory routine the search for neurocysticercosis (NC) in patients presenting with epileptic seizures because of the high risk of acquiring NC in our region and its potential cause of epilepsy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study is to evaluate cyst wall and protoscolex as an alternate source of antigen in serodiagnosis of cystic echinococcosis (CE). A total of 90 blood samples, 30 each of confirmed CE cases, disease controls and healthy controls were collected. Dot-ELISA using cyst wall, protoscolex and cyst fluid were used to demonstrate anti-hydatid antibodies. The sensitivity of Dot-ELISA using cyst wall, protoscolex and cyst fluid was 96.66%, 86.66% and 93.33% respectively and the specificity of the assay was 70% for Dot-ELISA using cyst fluid, protoscolex and cyst wall antigens. Results of the present study show that cyst wall and protoscolex can also be an useful source of antigen in detection of hydatid antibodies in the serodiagnosis of CE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Toxoplasmosis is an usually asymptomatic worldwide disseminated infection. In its congenital presentation it may lead to abortion or fetal malformations. Antenatal evaluation is considered of paramount importance to identify seronegative women and allow for prophylaxis. Recent improvements in sensitivity of IgM tests has made IgM detection an extremely protracted acute phase marker, and IgG avidity evaluation test became necessary. Observation has shown that a correlation can be established between IgM levels and avidity percentages, suggesting that frequently the avidity test may not be necessary. In this study we analyzed Toxoplasma gondii IgM levels of 202 samples and their IgG avidity percentages, in order to define specific levels whose IgM quantification could by itself define serodiagnosis and therefore make the avidity evaluation unnecessary. We showed that for IgM levels bellow 2.0 and above 6.0 serodiagnosis of toxoplasmosis could be established without need of IgG avidity test. IgM levels between these two parameters are associated with varying avidity indexes highlighting the importance of its evaluation as a means to confirm toxoplasmosis. Following this demonstration it was possible to avoid the avidity test for 75% of the cases, to reduce the turnaround time and to reduce costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine the prevalence of anti-T. gondii total and IgM antibodies in women of childbearing age. One hundred serum samples of women were studied with age range from 11 to 45 years old. Samples were chosen by random. The determination of total antibodies was carried out through the indirect hemagglutination technique and IgM antibodies by ELISA's technique. The statistical analysis was carried out through the Chi square and the Spearman correlation tests. The theoretical estimated incidence of congenital toxoplasmosis was calculated, according to the annual increment of antibody prevalence among the age groups. The overall prevalence of toxoplasmosis was 33%, while only six individuals (18.2%) were positive to IgM. The highest prevalence was observed in the 11-35 year-old age group. The theoretical estimated incidence was 1.5 for 100 pregnancies in women of 21-25 year-old group; it decreased until 0.1% in the 41-45 year-old age group. The findings show a high prevalence of toxoplasmosis in this community with a high infection risk in women of the studied age group and the high cat population observed, suggesting that the transmission way by contaminated soils may play a main role in the spreading of toxoplasmosis in this community.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to estimate the frequency of human toxocariasis in Cauday district, Cajamarca, Peru, using a dot-ELISA test. From June to October 2005, a total of 256 adult subjects were studied. Blood samples were collected for serology by a dot-ELISA test and for hematological examination. Parasitological examination was also carried out in stool samples to check cross-reactions in the dot-ELISA. The frequency observed was 44.92%, with a significant higher proportion of positivity in male subjects. From subjects with positive serology, 45.6% had respiratory symptoms, 40.44% abdominal pain, 32.35% hepatic symptoms, 14.7% cutaneous signs, 13.23% ocular manifestations, 43.38% eosinophilia, and all of these were statistically associated to serology. Among the population evaluated, 90.23% (231/256) were parasitized. From subjects with positive serology, 92.17% had at least one intestinal parasite and the most frequent were: Blastocystis hominis (68.38%), Giardia lamblia (28.68%), Hymenolepis nana (20.0%), Ascaris lumbricoides (15.65%), Entamoeba histolytica/E. dispar (13.24%), Cyclospora cayetanensis (4.41%), Cryptosporidium sp. (1.47%), Enterobius vermicularis (0.87%), Strongyloides stercoralis (0.87%), Taenia sp. (0.87%), and Trichuris trichiura (0.87%). The rate of false positives in the dot-ELISA test was improved by serum absorption each with A. suum antigens, with a decrease of cross-reactions. In conclusion, human toxocariasis is highly frequent in this population and some risk factors like dog/cat ownership, presence of pets within house, and previous history of geophagia were observed in the present study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Toxoplasma gondii causes severe fetal disease during acute infection in pregnant women, thus demanding early diagnosis for effective treatment and fetus preservation. Fetal tests are inefficient and risky, and diagnosis is based on maternal IgM serology, which had weak screening ability due to increased sensitivity, with alternative IgG avidity tests. Here, we performed ELISA and avidity assays using a recombinant T. gondii antigen, rROP2, in samples from 160 pregnant women screened from a large public hospital who were referred due to positive IgM assays. IgG serology and avidity assays were compared using whole T. gondii extract or rROP2. ELISA IgG detection with rROP2 showed good agreement with assays performed with T. gondii extract, but rROP2 IgG avidity assays were unrelated to whole extract antigen IgG avidity, regardless of the chaotrope used. These data show that avidity maturation is specific to individual antigen prevalence and immune response during infection. ELISA rROP2 IgG assays may be an alternative serological test for the diagnosis of toxoplasmosis during pregnancy, although our data do not support their use in avidity assays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indirect immunofluorescence is the method recommended for the diagnosis of visceral leishmanisis in dogs, however, the accuracy of this technique is low and its use on a large scale is limited. Since ELISA does not present these limitations, this technique might be an option for the detection of IgG or specific IgG1 and IgG2 subclasses. Canine ehrlichiosis is an important differential diagnosis of American Visceral Leishmaniasis (AVL). The present study compared ELISA using Leishmania chagasi and Leishmania braziliensis antigen for the detection of anti-Leishmania IgG and subclasses in serum samples from 37 dogs naturally infected with L. chagasi (AVL) and in samples from four dogs co-infected with L. braziliensis and L. chagasi (CI). The occurrence of cross-reactivity was investigated in control serum samples of 17 healthy dogs (HC) and 35 infected with Ehrlichia canis (EC). The mean optical density obtained for the detection of IgG was significantly higher when L. chagasi antigen was used, and was also higher in subgroup VLs (symptomatic) compared to subgroup Vla (asymptomatic). The correlation between IgG and IgG1 was low. The present results suggest that IgG ELISA using homologous antigen yields the best results, permitting the diagnosis of asymptomatic L. chagasi infection and the discrimination between cases of AVL and ehrlichiosis in dogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work evaluated the diagnostic accuracy of detection of Dengue NS1 antigen employing two NS1 assays, an immunochromatographic assay and ELISA, in the diagnostic routine of Public Health laboratories. The results obtained with NS1 assay were compared with virus isolation and, in a subpopulation of cases, they were compared with the IgM-ELISA results obtained with convalescent samples. A total of 2,321 sera samples were analyzed by one of two NS1 techniques from March to October 2009. The samples were divided into five groups: groups I, II and III included samples tested by NS1 and virus isolation, and groups IV and V included patients with a first sample tested by NS1 and a second sample tested by IgM-ELISA. Sensitivity, specificity, positive and negative predictive values, Kappa Index and Kappa Concordance were calculated. The results showed that NS1 testing in groups I, II and III had high sensitivity (98.0%, 99.5% and 99.3%), and predictive values and Kappa index between 0.9 - 1.0. Groups IV and V only had Kappa Concordance calculated, since the samples were analyzed according to the presence of NS1 antigen or IgM antibody. Concordance of 92.1% was observed when comparing the results of NS1-negative samples with IgM-ELISA. Based on the findings, it is possible to suggest that the tests for NS1 detection may be important tools for monitoring the introduction and spread of Dengue serotypes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the indirect hemagglutination (IH), indirect immunofluorescence (IIF) and enzyme linked immunosorbent assay (ELISA) tests for the diagnosis of Chagas disease, 4000 serum samples were examined. This study was conducted with different purposes: clinical interest, research support and parasitological monitoring of those patients with Chagas disease who were treated with heart transplantations. The tests occurred without patient selection and in accordance with the medical requests. The results showed discrepancies and brought about several questions, considering the different results that all three methods showed when considered together. What was found brought about concerns and we suggest the adoption of different measures, aiming to avoid these mismatches in the context of this disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foodborne diseases represent operational risks in industrial restaurants. We described an outbreak of nine clustered cases of acute illness resembling acute toxoplasmosis in an industrial plant with 2300 employees. These patients and another 36 similar asymptomatic employees were diagnosed with anti-T. gondii IgG titer and avidity by ELISA. We excluded 14 patients based on high IgG avidity and chronic toxoplasmosis: 13 from controls and one from acute disease other than T. gondii infection. We also identified another three asymptomatic employees with T.gondii acute infection and also anti-T. gondii IgM positive as remaining acute cases. Case control study was conducted by interview in 11 acute infections and 20 negative controls. The ingestion of green vegetables, but not meat or water, was observed to be associated with the incidence of acute disease. These data reinforce the importance of sanitation control in industrial restaurants and also demonstrate the need for improvement in quality control regarding vegetables at risk for T. gondii oocyst contamination. We emphasized the accurate diagnosis of indexed cases and the detection of asymptomatic infections to determine the extent of the toxoplasmosis outbreak.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work compared the time at which negative seroconversion was detected by conventional serology (CS) and by the ELISA-F29 test on a cohort of chronic chagasic patients treated with nifurtimox or benznidazole. A retrospective study was performed using preserved serum from 66 asymptomatic chagasic adults under clinical supervision, and bi-annual serological examinations over a mean follow-up of 23 years. Twenty nine patients received trypanocide treatment and 37 remained untreated. The ELISA-F29 test used a recombinant antigen which was obtained by expressing the Trypanosoma cruzi flagellar calcium-binding protein gene in Escherichia coli. Among the untreated patients, 36 maintained CS titers. One patient showed a doubtful serology in some check-ups. ELISA-F29 showed constant reactivity in 35 out of 37 patients and was negative for the patient with fluctuating CS. The treated patients were divided into three groups according to the CS titers: in 13 they became negative; in 12 they decreased and in four they remained unchanged. ELISA-F29 was negative for the first two groups. The time at which negativization was detected was significantly lower for the ELISA-F29 test than for CS, 14.5 ± 5.7 and 22 ± 4.9 years respectively. Negative seroconversion was observed in treated patients only. The results obtained confirm that the ELISA-F29 test is useful as an early indicator of negative seroconversion in treated chronic patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Serum samples from 150 NS1-negative (Platelia ELISA) patients presumptively diagnosed with dengue were analyzed by the TaqMan probed real-time reverse transcription PCR (TaqMan qRT-PCR) method. The qRT-PCR positive samples were tested for serotype by semi-nested RT-PCR and a qualitative immunochromatographic assay for IgG and IgM. Molecular detection methods showed 33 (22%) positive samples out of 150 NS1-antigen negative samples. Of these, 72% were collected up to day 2 after the onset of symptoms, when diagnostic sensitivity of NS1-antigen test assays is significantly enhanced. Most of the cases were not characterized as secondary infection. Twenty-eight samples were successfully serotyped, 75% of which for DENV-4, 14% for DENV-2, 7% for DENV-3 and 4% for DENV-1. These findings reaffirm the hyperendemic situation of the state of Roraima and suggest a lower sensitivity of the NS1 test, mainly when DENV-4 is the predominant serotype. Health care providers should therefore be aware of samples tested negative by NS1 antigen assays, especially when clinical symptoms and other laboratory data results show evidence of dengue infection.