400 resultados para Rede de detecção
Resumo:
The difference between the actual ECN 42 triacylglyceride content in vegetable oils, obtained by HPLC analysis, and the theoretical value calculated from the fatty acid composition was applied to detect the addition of seed oils with high contents of linoleic acid to olive oils commercialized in Brazil. The results indicate that samples analyzed were probably adulterated with low commercial value seed oils, rich in linoleic acid, like soybean, sunflower or corn.
Resumo:
The performances of eight kinds of insulators from electrical distribution lines in Salvador-BA, Brazil, were evaluated considering the chemical and physical local environmental pollution. The parameters that were chosen as characteristic for the insulators' properties were leakage current and partial electrical discharge. A data storage processing system and a communication link to the lab were built for data acquisition. The results show that the main contribution to the poor performance of the insulators is settleable magnetite particulate matter on the insulator in addition to the long term wetness time, t4.
Detecção de contaminantes em espécie bioindicadora (Corbicula fluminea) - Rio Ribeira de Iguape - SP
Resumo:
The study assessed heavy metal concentrations in the tissue samples of Corbiculafluminea, by ICP-OES. In the tissues, average levels of 23.99 µg/g of Cu, 144.21 µg/g of Zn, 0.71 µg/g of Cd, 7.10 µg/g of Cr and 2.41 µg/g of Pb were detected ahowing that this last value is high and above the ANVISA reference (2.00 µg/g) for fish and other products. The results suggest that natural processes occuring in the Ribeira de Iguape River are not sufficient for purification so that metals remain in the water and can accumulate in the trophic chain.
Resumo:
The detection of anionic species is a field which is currently attracting increasing interest. Research is carried out not only to gain a better understanding of biological events that anions participate in, but also to ascertain the potential contribution of the anionic chemosensors to the qualitative and quantitative analysis of species of interest in the areas of industry, medicine, the environment, and chemistry. This review summarizes several aspects related to the main strategies used in anion sensing. Each strategy discussed is illustrated with its potential applications citing recent examples. The prospects for their use in several areas are also described.
Resumo:
This paper describes the development and validation of simple and selective analytical method for determination of 3.4-methylenedioxymethamphetamine (MDMA) in Ecstasy tablets, using high performance liquid chromatography with fluorescence detection. Analysis was performed in a reversed phase column (LiChrospher 100 C18, 150 x 4.6 mm, 5 µm), isocratic elution with phosphate buffer 25 mmol/L pH 3.0 and acetonitrile (95:5, v/v). The method presents adequate linearity, selectivity, precision and accuracy. MDMA concentration in analyzed tablets showed a remarkable variability (from 8.5 to 59.5 mg/tablet) although the tablet weights were uniform, indicating poor manufacturing control thus imposing additional health risks to the users.
Resumo:
Analysis at microenvironments, like single cells or in minute volumes (nL), is an area of great interest for analytical and biological sciences. Measurements at these experimental conditions demand analytical tools (microelectrodes) capable of monitoring with rapid response, good resolution and minimal perturbation of the system. The major drawbacks in producing these microscopic electrodes have been largely overcome, principally due to the development of new fabrication methods. In this review, these procedures are described with emphasis to those devoted to the construction of microelectrodes for application in microenvironments. Examples of our efforts to use these devices as effective electrochemical sensors are also addressed.
Resumo:
Optical chemical sensors with detection in the near and mid infrared region are reviewed. Fundamental concepts of infrared spectroscopy and optical chemical sensors are briefly described, before presenting some aspects on optical chemical sensors, such as synthesis of NIR and IR reagents, preparation of new materials as well as application in determinations of species of biological, industrial and environmental importance.
Resumo:
This work describes the development of a home-made capillary electrophoresis (CE) system based on the capacitively coupled contactless conductivity detection (C4D) for the separation of the metallic species Zn2+, Cr3+, Pb2+, Cd2+, Co2+, Cu2+, Ni2+ e Tl+. A background electrolyte composed of MES/Histidine 0,02 mol L-1 (pH 5.0) was optimized for the separation of the metallic species by using organic solvents and complexing agents as additives. The system allowed the determination of the metallic species using MES/Histidine 0,02 mol L-1 and methanol 5% (pH 5.0) as a background electrolyte, 15 kV separation voltage and hydrodynamic injection by gravity.
Resumo:
The presence of chloramphenicol residues in goat milk can cause toxic effects in the population. The present work consists of the optimization and validation of analytical methodology for determination of chloramphenicol residues in goat milk by GC/ECD. The extraction was made with ethyl acetate and the clean-up with SPE-C18. The identification was made by comparison of retention time and GC/MS, and the quantification by external standard. The method was selective, linearity (0.998), precise (5.8-13.4%), exact (69.87-73.71%) and robust. The LOD and LOQ of method were 0.030 and 0.10 μg/kg, respectively. The method was efficiently for analysis of chloramphenicol in goat milk.
Resumo:
An analytical method based on high-performance liquid chromatography with electrochemical detection has been developed and applied to the determination of Solvent blue 14 (SA-14) and Solvent red 24 (SV-24) in fuel samples. The dyes were better separated on C18 column, using a mobile phase composed of acetonitrile and ammonium acetate (90:10, v/v). Detection was carried out at an oxidation potential of +0.85V. The detector response was linear at concentration range of 7.50×10-8 - 1.50×10-6 mol L-1 (r = 0.997) for SA-14 and SV-24, respectively. The method was used to quantify these dyes in fuels samples with satisfactory accuracy and precision.
Resumo:
A simple ultra-performance liquid chromatographic method for the simultaneous determination of sildenafil citrate and tadalafil was developed and validated. Sample preparation was dissolution in methanol, followed by centrifugation and dilution (1:10) with methanol. Analysis was performed in an Acquity® UPLC system with Acquity® BEH C18 column (2.1 x 50 mm, with 1.7 μm particles). The elution was isocratic with phosphate buffer pH 2.3 and acetonitrile (65:35, v/v) at a flow rate of 0.7 mL/min. The method presented adequate specificity, linearity, precision and accuracy and allowed the determination of the drugs in seized forensic samples.
Resumo:
A computational method to simulate the changes in the electronic structure of Ga1-xMn xN was performed in order to improve the understanding of the indirect contribution of Mn atoms. This periodic quantum-mechanical method is based on density functional theory at B3LYP level. The electronic structures are compared with experimental data of the absorption edge of the GaMnN. It was observed that the indirect influence of Mn through the structural parameters can account for the main part of the band gap variation for materials in the diluted regime (x<0.08), and is still significant for higher compositions (x~0.18).
Resumo:
We optimized a method for the determination of three main folate isoforms in leafy vegetables. Analysis was carried out by HPLC, using gradient of elution and fluorescence detection. Limits of quantification were 2 ng/mL; 2 ng/mL and 28 ng/mL for tetrahydrofolate (THF), 5-methyltetrahydrofolate (5-MTHF) and 5-formyltetrahydrofolate (5-FTHF), respectively. Recovery rates of THF, 5-MTHF and 5-FTHF varied from 87.86 to 100.64%; 88.12-94.22% and 89.82-106.69%, respectively. Test of repeatability showed relative standard deviation for peak areas lower than 10%. Tests for linearity showed high coefficients of determination. The results showed advances in folates extraction and analysis in raw and cooked leafy vegetables.
Resumo:
The sulphur take an essential role in plants and it is one of the main nutrients in several metabolic processes. The dry ash oxidation, using alkaline oxidizers agent, is the simplest and most economical form for the oxidation of Organic S to sulfate in plants. The objective of this work is to propose a method for sulfur determination in plants samples using dry ash oxidation and agent oxidizers alkaline. The quantification of S-SO4(2-) in samples was accomplished by turbidimetric method. The results demonstrated that the proposed method for oxidation alkaline was appropriate.
Resumo:
This work presents the optimization of the microwave-assisted hydrothermal synthesis of [Zn(BDC)(H2O)2]n . The reactions were carried out at the fixed temperature of 120 ºC for 10, 20, 30 and 40 min. Pure crystalline [Zn(BDC)(H2O)2]n was obtained in high yield (ca. 90%) with a reaction time of 10 min. The phase obtained and its purity was confirmed by Rietveld refinement, with a final value for Rwp/Rexp equal to 1.48. Increased reaction times (20, 30 and 40 min) favored the formation of unwanted by products, resulting in mixtures of several crystalline phases.