312 resultados para antioxidant determination
Resumo:
In this research, scanometry was used as a new, simple, fast and inexpensive method for a colorimetric determination of Mn2+ ion in water samples and thermocouple wire through the use of periodate reagent in an acidic medium. The results showed the oxidization of colorless Mn2+ ion by periodate and the formation of a purplish MnO4- ion. The system had a linear range of 1.0 to 70.0 µg mL-1 Mn2+ ion with a detection limit of 0.314 µg mL-1 and a relative standard deviation of 2.77% for G color value. This method has the capability to determine low levels of Mn2+ ion in thermocouple wire and water samples.
Resumo:
A simple preconcentration method of silicon based on coprecipitation with aluminum hydroxide prior to its flame atomic absorption (FAAS) determination was established. The recovery values of analyte ion was higher than 95%. The parameters including types of hydroxide ion source for precipitation, acid type for dissolution step, amount of aluminum ion as collector, pH, temperature, standing and centrifuge time, and sample volume were optimized for the quantitative recovery of the analyte. The influences of matrix ions were also examined. The relative standard deviation was found to be 3.2%. The limit of detection was calculated as (0.1 mg L-1). The preconcentration factor is 100 for (200 mL) solution. The proposed method was successfully applied for the determination of silicon in some water and alloy samples.
Resumo:
In this paper, a silica-gel-modified carbon paste electrode (Si-gel/CPE) was used to determine the anti-cancer drug emodin by anodic stripping differential pulse voltammetry (ASDPV). The effects of the silica-gel content, the pH of the supporting electrolyte, and the scan rate on the oxidation current of emodin were investigated. The oxidation currents of emodin obtained from ASDPV measurements were linearly correlated with the concentration in the range of 5.0 × 10-9 to 300.0 × 10-9 mol L-1. The limit of detection was determined to be 1.5 × 10-9 mol L-1. The current method was successfully applied to determine emodin in a knotweed root sample, with recovery rate of 92.5% to 98.3%.
Resumo:
This paper describes the optimization of a multiresidue chromatographic analysis for the identification and quantification of 20 pesticides in bovine milk, including three carbamates, a carbamate oxime, six organophosphates, two strobilurins, a pyrethroid, an oxazolidinedione, an aryloxyphenoxypropionate acid/ester, a neonicotinoid, a dicarboximide, and three triazoles. The influences of different chromatographic columns and gradients were evaluated. Furthermore, four different extraction methods were evaluated; each utilized both different solvents, including ethyl acetate, methanol, and acetonitrile, and different workup steps. The best results were obtained by a modified QuEChERS method that lacked a workup step, and that included freezing the sample for 2 hours at -20 ºC. The results were satisfactory, yielding coefficients of variation of less than 20%, with the exception of the 50 µg L-1 sample of famoxadone, and recoveries between 70 and 120%, with the exception of acephate and bifenthrin; however, both analytes exhibited coefficients of variation of less than 20%.
Resumo:
A method for the determination of trace amounts of palladium was developed using homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA) followed by graphite furnace atomic absorption spectrometry (GFAAS). Ammonium pyrrolidine dithiocarbamate (APDC) was used as a complexing agent. This was applied to determine palladium in three types of water samples. In this study, a special extraction cell was designed to facilitate collection of the low-density solvent extraction. No centrifugation was required in this procedure. The water sample solution was added to the extraction cell which contained an appropriate mixture of extraction and homogeneous solvents. By using air flotation, the organic solvent was collected at the conical part of the designed cell. Parameters affecting extraction efficiency were investigated and optimized. Under the optimum conditions, the calibration graph was linear in the range of 1.0-200 µg L-1 with a limit of detection of 0.3 µg L-1. The performance of the method was evaluated for the extraction and determination of palladium in water samples and satisfactory results were obtained. In order to verify the accuracy of the approach, the standard addition method was applied for the determination of palladium in spiked synthetic samples and satisfactory results were obtained.
Resumo:
Bioorganic and biological chemistry have been found to be highly motivating to undergraduate students and in this context, biochemical blood parameter analysis emerges as highly attractive content. In this proposal, several aspects related to analyses of glucose, cholesterol and triglycerides using the enzymatic colorimetric method were involved, and the findings have at least two relevant implications: i) introducing students to connections between organic chemistry and biology based on enzymatic processes, including reactivity and mechanistic aspects; ii) performing a micro scale bioassay analysis. The proposal requires two theoretical classes (2 h per class) and one practical class (4 h).
Resumo:
A simple and sensitive spectrophotometric method is proposed for the simultaneous determination of protocatechuic acid and protocatechuic aldehyde. The method is based on the difference in the kinetic rates of the reactions of analytes with [Ag(NH3)2]+ in the presence of polyvinylpyrrolidone to produce silver nanoparticles. The data obtained were processed by chemometric methods using principal component analysis artificial neural network and partial least squares. Excellent linearity was obtained in the concentration ranges of 1.23-58.56 µg mL-1 and 0.08-30.39 µg mL-1 for PAC and PAH, respectively. The limits of detection for PAC and PAH were 0.039 and 0.025 µg mL-1, respectively.
Resumo:
AbstractMany well-established methods for determining the antioxidant capacities in several samples have been described in literature. However, DPPH (2,2-diphenyl-1-picrylhydrazyl) and ABTS (2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid)) are the main two methods that utilize radicals as spectrophotometric probes for analysis. Nevertheless, these methods have certain limitations because of their slower kinetics, solvent polarity effects, the hydrophilicity and lipophilicity of the compounds, chemical costs, etc. In this study, a spectrophotometric method for determining the antioxidant capacity in beverages was developed based on an exploration of the cation radical derived from DEPD. This method was based on the oxidation of aromatic amines with Fe(III) ions at pH 4.0, which leads to their corresponding purple cation radicals (DEPD•+) with λmax values at 500 and 540 nm. The addition of an antioxidant after the formation of the radical leads to a reduction in color intensity that is proportional to the antioxidant concentration in the medium. Results obtained using this method were compared with the Folin-Ciocalteau, ABTS and DPPH methods in terms of applications in wines, teas, and infusions samples. Linear correlation analysis at a 95% confidence level was employed to compare the results, which were in good agreement with a correlation coefficient of r > 0.9000. Thus, the developed method was simple, accurate, and consistent with other assays for the determination of the total amount of phenolic compounds and antioxidant capacity.
Resumo:
The microencapsulation of palm oil may be a mechanism for protecting and promoting the controlled release of its bioactive compounds. To optimize the microencapsulation process, it is necessary to accurately quantify the palm oil present both external and internal to the microcapsules. In this study, we developed and validated a spectrophotometric method to determine the microencapsulation efficiency of palm oil by complex coacervation. We used gelatin and gum arabic (1:1) as wall material in a 5% concentration (w/v) and palm oil in the same concentration. The coacervates were obtained at pH 4.0 ± 0.01, decanted for 24 h, frozen (−40 ºC), and lyophilized for 72 h. Morphological analyzes were then performed. We standardized the extraction of the external palm oil through five successive washes with an organic solvent. We then explored the best method for rupturing the microcapsules. After successive extractions with hexane, we determined the amount of palm oil contained in the microcapsules using a spectrophotometer. The proposed method was shown to be of low cost, fast, and easy to implement. In addition, in the validation step, we confirmed the method to be safe and reliable, as it proved to be specific, accurate, precise, and robust.
Resumo:
In this study, dispersive liquid-liquid microextraction based on the solidification of floating organic droplets was used for the preconcentration and determination of thorium in the water samples. In this method, acetone and 1-undecanol were used as disperser and extraction solvents, respectively, and the ligand 1-(2-thenoyl)-3,3,3-trifluoracetone reagent (TTA) and Aliquat 336 was used as a chelating agent and an ion-paring reagent, for the extraction of thorium, respectively. Inductively coupled plasma-optical emission spectrometry was applied for the quantitation of the analyte after preconcentration. The effect of various factors, such as the extraction and disperser solvent, sample pH, concentration of TTA and concentration of aliquat336 were investigated. Under the optimum conditions, the calibration graph was linear within the thorium content range of 1.0-250 µg L-1 with a detection limit of 0.2 µg L-1. The method was also successfully applied for the determination of thorium in the different water samples.
LOW COST ANALYZER FOR THE DETERMINATION OF PHOSPHORUS BASED ON OPEN-SOURCE HARDWARE AND PULSED FLOWS
Resumo:
The need for automated analyzers for industrial and environmental samples has triggered the research for new and cost-effective strategies of automation and control of analytical systems. The widespread availability of open-source hardware together with novel analytical methods based on pulsed flows have opened the possibility of implementing standalone automated analytical systems at low cost. Among the areas that can benefit from this approach are the analysis of industrial products and effluents and environmental analysis. In this work, a multi-pumping flow system is proposed for the determination of phosphorus in effluents and polluted water samples. The system employs photometric detection based on the formation of molybdovanadophosphoric acid, and the fluidic circuit is built using three solenoid micropumps. The detection is implemented with a low cost LED-photodiode photometric detection system and the whole system is controlled by an open-source Arduino Uno microcontroller board. The optimization of the timing to ensure the color development and the pumping cycle is discussed for the proposed implementation. Experimental results to evaluate the system behavior are presented verifying a linear relationship between the relative absorbance and the phosphorus concentrations for levels as high as 50 mg L-1.
Resumo:
A method has been developed for the extraction and spectrophotometric determination of Hg2+ in a concentration range of 0.2-1.0 mg L-1; following the Lambert-Beer's law using high molecular weight quaternary ammonium salts dissolved in chloroform. The metal complex anion was determined in the extract in the region UV (260 nm).
Resumo:
The determination of the total calcium in juice, syrups, and other products of the sugar industry is investigated. Total calcium and free calcium is determinated by AAS and employing Ca-selective electrode respectively. A coefficient is obtained for the relation of total calcium with respect to free calcium. The coefficient is employed to determine the content of total calcium in accordance with the following equation.
Resumo:
A sorption concentration method using impregnated silica has been developed to determine small concentration of lead in water by Atomic Absorption Spectrometry.
Resumo:
Herbicides such as trifluralin, simazine, atrazine, metribuzin and metolachlor are used in Brazilian agriculture. The efficiency of a small scale method for determination of these herbicides and two degradation products (deisopropylatrazine and deethylatrazine) in soil samples was evaluated. The compounds were extracted from soil samples (5 g) with 20 ml of ethyl acetate in a mechanical shaker for 50 min. Following the extraction, the supernatant was dried through anhydrous sodium sulphate, concentrated and analysed by high resolution gas chromatography (HRGC) with thermionic specific detection (TSD). Mean recoveries obtained from soil samples fortified at three different levels ranged from 81 to 115% with relative standard deviation (RSD) values varying from 1.2 to 12.7%. The method detection limits ranged from 0.01 to 0.06 mg kg-1. The methodology was applied using soil samples from farms located near the town of Araraquara, in the State of São Paulo, Brazil.