Resumo:
Ascorbic acid has important nutritional characteristics such as high antioxidant potential, preventing diverse damage and diseases in the tissues and the process of aging. Different isomeric forms of the ascorbic acid can be found in nature and each one have different potential antioxidant and different activity pro-vitamin C. This work examined a method to detect and quantify the isomers L-ascorbic acid (LAA) and D-iso-ascorbic acid (DIAA) in jelly fruit. The method showed acceptable selectivity, linearity, repeatability and recovery. DIAA was not found in the analyzed samples, but LAA was found up to 605 mg in 100 g of sample.
Resumo:
Tibolone is a synthetic steroid used for prevention of bone loss and treatment of menopause symptoms. This article describes the development and validation of an analytical method to quantify tibolone in capsules using high performance liquid chromatography with UV detection. After chromatography conditions are established the validation parameters evaluated were specificity, linearity, precision, accuracy, detection and quantification limits and robustness. The method developed is effective to analyze tibolone in capsules, being able to be used in quality control laboratory routine.
Resumo:
A high performance liquid chromatographic-diode array detection method for the determination of busulfan in plasma was developed and validated. Sample preparation consisted of protein precipitation followed by derivatization with sodium diethyldithiocarbamate and liquid-liquid extraction with methyl-tert-butyl ether. Chromatograms were monitored at 277 nm. Separation was carried out on a Lichrospher RP 18 column (5 µm, 250 x 4 mm). The mobile phase consisted of water and acetonitrile (20:80, v/v). The method presented adequate specificity, linearity, precision and accuracy and allowed reliable determination of busulfan in clinical plasma samples, being applied to three patients submitted to bone marrow transplantation.
Resumo:
This study optimized and validated the liquid-liquid extraction technique with partition at low temperature (LLE-PLT) for identification and quantification of four pesticides (chlorpyrifos, λ-cyhalothrin, permethrin, bifenthrin) in water samples. Analyses were performed by HPLC-UV. The technique was efficient for pesticide recovery with extraction exceeding 86%. Chromatographic response was linear for the four compounds in the 10-45 µg L-1 range, with correlation coefficients greater than 0.99. Limits of detection and quantitation were less than 3.5 µg L-1 and equal to 10 µg L-1, respectively. The proposed method was applied to 29 water samples from the Jaíba Project in northern Minas Gerais.
Resumo:
Blooms of cyanobacteria represent a public health risk due to their cyanotoxins such as microcystins. Liquid chromatography techniques to separate and quantify microcystins invariably use acetonitrile as the organic component of the mobile phase. The price and availability of acetonitrile together with its elevated toxicity encourage the validation of acetonitrile-free methods of microcystin analysis. In this work, methanol was employed as the organic solvent of the mobile phase and the validation method was performed with different environmental water samples. The method showed limits of detection between 0.17 and 0.25 µg/L and of quantification between 0.55 and 0.82 µg/L for the microcystin variants: -RR, -YR, -LR, -LA.
Resumo:
This paper describes the use of the open source hardware platform, denominated "Arduino", for controlling solenoid valves for solutions handling in flow analysis systems. System assessment was carried out by spectrophotometric determination of iron (II) in natural water. The sampling rate was estimated as 45 determinations per hour and the coefficient of variation was lower than 3%. Per determination, 208 µg of 1-10-phenanthroline and ascorbic acid were consumed, generating 1.3 mL of waste. "Arduino" proved a reliable microcontroller with low cost and simple interfacing, allowing USB communication for solenoid device switching in flow systems.
Resumo:
Validation of a rapid method for the determination of ascorbic, citric, fumaric and tartaric acids in stored pulp fruit and its application as a quality parameter was performed. The validation parameters showed that for the four evaluated acids, the method presented low limits of detection (LOD) and quantification (LOQ), indicating good precision and accuracy, thus representing an important tool for quality assessment of stored fruit pulp. The results showed that the concentration of organic acids generally decreased with longer storage time in the fruit pulp under study. Amongst all the organic acids under investigation, ascorbic proved the least stable.
Resumo:
Carbamazepine, phenobarbital and phenytoin were determined in dried blood spots (DBS) by high performance liquid chromatography, after extraction of 8 mm DBS using a mixture of acetonitrile and methanol. Analytes were separated by reversed-phase chromatography, with a run time of 17 minutes. Intra-assay and inter-assay precisions were in the 5.3 to 8.4% and 3.3 to 5.2% ranges, respectively. Accuracy was in the 98.8 to 104.3% range. The method had sensitivity to detect all analytes at levels below minimum therapeutic concentrations. The analytes were stable at 4 ºC and room temperature for up to 12 days and at 45 ºC for 9 days. The method was applied to 14 paired clinical samples of blood serum and DBS.
Resumo:
In this work, a novel device based on polyacrylamide (PAAm) hydrogels and KL - DeOH - H2O lyotropic liquid crystal (LLC), with potential for application as Polymer Dispersed Liquid Crystals (PDLC), was proposed and its properties characterized. The confinement of LLC promoted significant changes in spectroscopic, morphological, optical, hydrophilic, structural and mechanical properties due to the interaction between the LLC-PAAm matrix and entropic parameter changes. The mechanical and structural properties can be controlled by adjusting AAm, temperature and presence of LLC, which can be useful for technological applications of these systems in optical devices.
Resumo:
The filling of capillaries via the sol-gel process is growing. Therefore, this technical note focuses on disseminating knowledge acquired in the Group of Analytical Chemistry and Chemometrics over seven years working with monolithic stationary phase preparation in fused silica capillaries. We believe that the detailed information presented in this technical note concerning the construction of an alternative high pressurization device, used to fill capillary columns via the sol-gel process, which has promising potential for applications involving capillary electrochromatography and liquid chromatography in nano scale, may be enlightening and motivating for groups interested in developing research activities within this theme.
Resumo:
AbstractA device comprising a lab-made chamber with mechanical stirring and computer-controlled solenoid valves is proposed for the mechanization of liquid-liquid extractions. The performance was demonstrated by the extraction of ethanol from biodiesel as a model of the extraction of analytes from organic immiscible samples to an aqueous medium. The volumes of the sample and extractant were precisely defined by the flow-rates and switching times of the valves, while the mechanic stirring increased interaction between the phases. Stirring was stopped for phase separation, and a precise time-control also allowed a successful phase separation (i.e., the absence of the organic phase in the aqueous extract). In the model system, a linear response between the analytical response and the number of extractions was observed, indicating the potential for analyte preconcentration in the extract. The efficiency and reproducibility of the extractions were demonstrated by recoveries of ethanol spiked to biodiesel samples within 96% and 100% with coefficients of variation lower than 3.0%.
Nematoses de alta importância econômica da cultura do melão no estado do Rio Grande do Norte, Brasil
Resumo:
A obtenção de soros policlonais contra fitopatógenos tem por finalidade a elaboração de imunoensaios que permitam identificar e caracterizar os mesmos com rapidez e a custos baixos. Soros policlonais foram produzidos contra extratos das hifas de isolados de Crinipellis perniciosa, agente causal da vassoura-de-bruxa, coletados de cacaueiro (Theobroma cacao) nos estados do Pará e Bahia para identificação e caracterização de isolados de diversas regiões e hospedeiros. O soro denominado de 1 foi produzido a partir do isolado ESJOH-1 (originário do Pará), e o soro 2 foi produzido com o isolado CP-85 (originário da Bahia). Não houve reação cruzada dos soros contra extratos protéicos das espécies Alternaria solani, Marasmius sp., Oudemansiella canarii e Verticillium fungicola. Os soros apresentaram reação cruzada de alta afinidade com extratos de Moniliophthora roreri e de baixa a média afinidade com Marasmius cladophyllus. A caracterização dos isolados foi feita com amostras do biotipo-C coletados no Amazonas, Bahia, Mato Grosso, Rondônia e Pará. As reações sorológicas dos dois soros não permitiram diferenciar os isolados do Pará e da Bahia, contra os quais foram produzidos, e também não reagiram diferencialmente com isolados de outros estados. O reconhecimento dos antígenos entre os soros foi variável, pois o soro 1 e soro 2 apresentaram reação sorológica diferenciada para alguns isolados. Os soros produzidos apresentaram alta afinidade contra isolados dos biotipos-C e S, independente de sua origem geográfica, podendo ser usados para identificação.