328 resultados para Cardiac imagens
Resumo:
OBJETIVO: Pesquisar visualizadores de imagens médicas gratuitos disponíveis na internet capazes de funcionar como cliente PACS (picture archiving and communication system) e avaliar suas principais funções e a viabilidade do uso em computadores pessoais. MATERIAIS E MÉTODOS: Foi feita pesquisa, no Google e em sites especializados, por programas gratuitos disponíveis para o Windows. Foram encontrados cerca de 70, sendo 11 capazes de funcionar como cliente PACS, e selecionados seis destes para análise: ClearCanvas Workstation, KPACS, Onis, Synedra View Personal, Mito e Tudor DicomViewer. Com base nas necessidades dos autores, 16 funções foram avaliadas. RESULTADOS: Dos seis programas avaliados, dois possuem 10 das 16 funções avaliadas e um possui apenas duas. Três realizam MPR (reconstrução multiplanar), um realiza MIP (reconstrução por projeção de intensidade máxima), dois realizam VR (renderizações volumétricas), dois funcionam como servidor PACS, dois geram CDs, um realiza fusão de imagens, três permitem utilizar múltiplos monitores e apenas um não é compatível com Windows 7. CONCLUSÃO: Diversos programas gratuitos estão disponíveis e não existe nenhum completo. Cabe ao usuário analisar e selecionar o programa que melhor se enquadra nas suas necessidades, porém, os programas Onis, Synedra e ClearCanvas se destacam, cada um com suas peculiaridades. É totalmente viável o uso de programas gratuitos para o dia-a-dia do radiologista.
Resumo:
OBJETIVO: Propor um método reprodutível, de fácil utilização e de baixo custo para a digitalização de filmes radiográficos de todos os tamanhos padrões, concentrando nossos esforços em filmes radiográficos de tórax. MATERIAIS E MÉTODOS: O objetivo de baixo custo ditou o uso de um escâner A4 com adaptador de transparência, bem como um software de costura de imagens otimizado, que tira proveito da geometria do escâner e área de captura constante, bem como o conhecimento das dimensões dos filmes radiográficos padrões. RESULTADOS: O resultado final do método proposto é uma imagem de alta resolução com bom contraste e sem artefatos de costura perceptíveis. CONCLUSÃO: O método de digitalização proposto usando um escâner A4 possibilita reprodutibilidade, excelente qualidade de imagem e alto grau de certeza na identificação de lesões.
Integrando ferramentas de auxílio ao diagnóstico no sistema de arquivamento e comunicação de imagens
Resumo:
OBJETIVO: Este artigo apresenta um modelo de integração de algoritmos de diagnóstico auxiliado por computador dentro do fluxo de trabalho dos sistemas de gerenciamento de imagens, desenvolvido com base em um conjunto de ferramentas computacionais de código aberto e uso livre chamado dcm4che2. MATERIAIS E MÉTODOS: O modelo de integração é composto por um servidor de processamento de imagens e por serviços de comunicação. O gerenciamento de dados segue o fluxo de trabalho definido pelo perfil de pós-processamento (PWF) do Integrating the Healthcare Enterprise (IHE) e utiliza a funcionalidade de captura secundária do DICOM. Uma aplicação para lesões difusas de pulmão foi utilizada para prova de conceito. RESULTADOS: O algoritmo de classificação de padrões apresentou acurácia de 78%, com base em um método de teste de validação cruzada. A integração possibilita a visualização das imagens processadas como uma nova série dentro do estudo original. CONCLUSÃO: O modelo de integração proposto baseiase em perfis do IHE e permite o estabelecimento de procedimentos padronizados. Os princípios utilizados para integração do fluxo de trabalho são aplicáveis para qualquer tarefa não interativa de pós-processamento de imagens.
Resumo:
As anomalias congênitas do trato urinário superior implicam modificações morfofuncionais com espectro clínico variável, desde manifestações assintomáticas até falência renal e incompatibilidade com a vida. A tomografia computadorizada, além de ter superado o método de imagem da urografia excretora, tem desempenhado papel fundamental no diagnóstico das anomalias congênitas, orientando melhor nas decisões terapêuticas clínicas e cirúrgicas, além de atuar como ferramenta essencial na identificação de complicações associadas e no melhor desempenho de técnicas operatórias menos invasivas.
Resumo:
Complications from central venous catheterization include infectious conditions, pneumothorax, hemothorax and venous thrombosis. Pericardial effusion with cardiac tamponade hardly occurs, and in infants is generally caused by umbilical catheterization. The authors describe the case of cardiac tamponade occurred in an infant during chest computed tomography with contrast infusion through a central venous catheter inserted into the right internal jugular vein.
Resumo:
Objective To evaluate and describe indications, mainly diagnoses and cardiac magnetic resonance imaging findings observed in clinical practice. Materials and Methods Retrospective and descriptive study of cardiac magnetic resonance performed at a private hospital and clinic in the city of Niterói, RJ, Brazil, in the period from May 2007 to April 2011. Results The sample included a total of 1000 studies performed in patients with a mean age of 53.7 ± 16.2 years and predominance for male gender (57.2%). The majority of indications were related to assessment of myocardial perfusion at rest and under pharmacological stress (507/1000; 51%), with positive results in 36.2% of them. Suspected myocarditis was the second most frequent indication (140/1000; 14%), with positive results in 63.4% of cases. These two indications were followed by study of arrhythmias (116/1000; 12%), myocardial viability (69/1000; 7%) and evaluation of cardiomyopathies (47/1000; 5%). In a subanalysis, it was possible to identify that most patients were assessed on an outpatient basis (58.42%). Conclusion Cardiac magnetic resonance has been routinely performed in clinical practice, either on an outpatient or emergency/inpatient basis, and myocardial ischemia represented the main indication, followed by investigation of myocarditis, arrhythmogenic right ventricular dysplasia and myocardial viability.
Resumo:
Objetivo: Este artigo apresenta uma forma de se obterem estimativas de dose em pacientes submetidos a tratamentos radioterápicos a partir da análise das regiões de interesse em imagens de medicina nuclear. Materiais e Métodos: Foi desenvolvido o software denominado DoRadIo (Dosimetria das Radiações Ionizantes), que recebe as informações sobre os órgãos fontes e o órgão alvo e retorna resultados gráficos e numéricos. As imagens de medicina nuclear utilizadas foram obtidas de catálogos disponibilizados por físicos médicos. Nas simulações utilizaram-se modelos computacionais de exposição constituídos por fantomas de voxels acoplados ao código Monte Carlo EGSnrc. O software foi desenvolvido no Microsoft Visual Studio 2010 com o modelo de projeto Windows Presentation Foundation e a linguagem de programação C#. Resultados: Da aplicação das ferramentas foram obtidos: o arquivo para otimização das simulações Monte Carlo utilizando o EGSnrc, a organização e compactação dos resultados dosimétricos com todas as fontes, a seleção das regiões de interesse, a contagem da intensidade dos tons de cinza nas regiões de interesse, o arquivo das fontes ponderadas e, finalmente, todos os resultados gráficos e numéricos. Conclusão: A interface de usuários pode ser adaptada para uso em clínicas de medicina nuclear como ferramenta computacional auxiliar na estimativa da atividade administrada.
Resumo:
Abstract Ischemic cardiomyopathy is one of the major health problems worldwide, representing a significant part of mortality in the general population nowadays. Cardiac magnetic resonance imaging (CMRI) and cardiac computed tomography (CCT) are noninvasive imaging methods that serve as useful tools in the diagnosis of coronary artery disease and may also help in screening individuals with risk factors for developing this illness. Technological developments of CMRI and CCT have contributed to the rise of several clinical indications of these imaging methods complementarily to other investigation methods, particularly in cases where they are inconclusive. In terms of accuracy, CMRI and CCT are similar to the other imaging methods, with few absolute contraindications and minimal risks of adverse side-effects. This fact strengthens these methods as powerful and safe tools in the management of patients. The present study is aimed at describing the role played by CMRI and CCT in the diagnosis of ischemic cardiomyopathies.
Resumo:
This paper describes an approach for the colour-based classification of RGB (red-green-blue) images, acquired using a common scanner, of commercial carbonated soft drinks. Mean histograms of image colour channels were evaluated for the PCA classification of 29 brands of Guaraná, Cola, and orange flavors. Loadings for principal component axes resulted in different patterns for sample grouping on score plots according to RGB histograms. pH, sorbic acid and sucrose measurements were also correlated to the analyzed brands through PCA score plots of the digitalized images.
Resumo:
This report describes a study about the feasibility of using a conventional digital camera, a cell-phone camera, an optical microscope, and a scanner as digital image capture devices on printed microzones. An array containing nine circular zones was drawn using graphics software and printed onto transparency film by a laser printer. Due to its superior analytical performance, the scanner was chosen for the quantitative determination of Fe2+ in pharmaceutical samples. The data achieved using scanned images did not differ statistically from those attained by the reference spectrophotometric method at the confidence level of 0.05.
ANÁLISE MULTIVARIADA DE IMAGENS NA QUÍMICA: UM EXPERIMENTO PARA DETERMINAÇÃO DO pH DE ÁGUAS POTÁVEIS