420 resultados para Café - Extração da cafeína


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study the factors that affect the extraction of pesticide residues from water samples for their determination by solid-phase micro-extraction (SPME) and GC/MS were optimized. The fiber polymer, the extraction mode, the ionic strength, the stirring rate, the pH and the extraction time were the most significant parameters evaluated. The recovery obtained with the proposed method ranged from 94 to 110% and the sensitivity of the method, determined by calculating the detection limit (DL), ranged from 0.004 to 0.1 mug l-1. The results obtained with spiked real samples, at the 0.1 mug l-1 level, showed acceptable conformity with the expected values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the preparation of the xerogel anilinepropylsilica is reported. The ability of the xerogel for extracting Al(III), Cr(III) and Fe(III) from ethanol was investigated at 25 ºC. The xerogel adsorption capacities were obtained from the adsorption isotherms by using the batch method. Flame atomic absorption spectrometry (FAAS) was used to estimate the concentration of metal ions in solution. The adsorption affinity follows the series Cr(III) > Fe(III) > Al(III) and the maximum adsorption capacities of the metal ions were 0.61, 0.52 and 0.43 mmol g-1, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes methodologies for the extraction and characterization by TLC, UV-VIS, IR and NMR of bixin from Bixa orellana L. (urucum) seeds. Based on the results, the extraction with NaOH 5% is the fastest, uses low-cost materials, requires two to four laboratory hours and is a useful alternative for an experimental Organic Chemistry discipline.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the feasibility of employing micelle-mediated extraction for selective separation of homologous or isomeric organic compounds is demonstrated. Firstly, the main parameters controlling extraction performances, such as surfactant concentration and temperature were varied. A Scheffé-type experimental design was demonstrated as a novel and useful method to characterize the various experimental factors. At each point selected in the two-phase domain and for a given solute, extraction percentage (E%), concentration ratio, phase volume ratio, and equilibrium partition coefficient (K C) were determined. The values of E% and K C decrease in the following order: phenol > 1-phenylethanol ~ 2-phenylethanol > benzyl alcohol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coffee is a product consumed all around the world, Brazil being the biggest exporter. However, little is known about the difference in composition of the different brands in terms of bioactive substances. In the present study, ten of the most consumed brands of coffee in Rio de Janeiro were analyzed. Caffeine contents, trigonelline and total chlorogenic acid varied from 0.8 g/100g to 1.4 g/100g; 0.2 g/100g to 0.5 g/100g and from 3.5 g kg-1 to 15.9 g kg-1, respectively. The large heterogeneity observed in the amounts of the bioactive compounds can be attributed to different formulations of the various brands, as well as to different roasting conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solid phase extraction (SPE) in C18 disks has been optimized and validated for extraction of 5 organophosphorus (OP) pesticides in water. Extraction has been followed by separation and detection by gas chromatography/flame photometry. Excellent linearity was obtained for all compounds (r greater than 0.99), with CVs between 1.0-6.9%, recoveries between 73-95% and quantification limits between 2.5-5.0 µg L-1. Samples from Furnas dam were analyzed monthly during one year and 10% showed OP pesticide residues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analysis of diazepam (DZP) and its active metabolite nordiazepam (NDZP) in plasma is commonly performed in clinical medicine to ensure proper therapeutic effects while minimizing the incidence of toxicity. This study aimed to optimize analytical parameters and compare two pre-treatment techniques, liquid-liquid (LLE) and solid phase extraction (SPE), as well as liquid chromatographic conditions to analyze simultaneously DZP and NDZP in plasma from 20 patients treated with a daily dose of 10 mg. Both techniques showed to be well in line with the international criteria for analytical validation, which permitted to quantify DZP (66.2 - 1148.6 ng mL-1) and NDZP (138.5 - 808.6 ng mL -1) in all samples. The correlation coefficients between SPE and LLE were respectively 0.9729 for DZP and 0.9643 for NDZP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MIPs are synthetic polymers that are used as biomimetic materials simulating the mechanism verified in natural entities such as antibodies and enzymes. Although MIPs have been successfully used as an outstanding tool for enhancing the selectivity or different analytical approaches, such as separation science and electrochemical and optical sensors, several parameters must be optimized during their synthesis. Therefore, the state-of-the-art of MIP production as well as the different polymerization methods are discussed. The potential selectivity of MIPs in the extraction and separation techniques focusing mainly on environmental, clinical and pharmaceutical samples as applications for analytical purposes is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Malaria is still one of the major diseases in the world, causing physical and economic problems in tropical regions. Artemisinin (Qinghaosu), a natural compound identified in Artemisia annua L. , is an effective drug mainly against cerebral malaria. The action of this drug is immediate and parasitaemia in the treatment of drug-resistant malaria is rapidily reduced, justifying the industrial production of artemisinin. This article focuses on the industrial production of this potent antimalarial drug, including strategies for enhancing yield using inexpensive and easy steps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is a review about the use of Blue rayon in the extraction and concentration of environmental contaminants in the aquatic environment. Blue rayon is an adsorbent composed of fibers covalently linked with copper phthalocyanine trisulphonate that has the ability to selectively adsorb polycyclic compounds. Blue rayon can be used in situ, in columns or in flasks. This method showed to be efficient in the extraction of important classes of environmental contaminants like the polycyclic aromatic hydrocarbons (PAHs), aromatic amines and phenylbenzotriazoles (PBTAs) and can be an important tool in monitoring studies for the evaluation of water quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an easy and practical procedure to obtain silica-based C-8 type sorbents for use in solid-phase extraction. The materials are prepared by depositing poly(methyloctylsiloxane), PMOS, on the silica support. Two different treatments for immobilization were used: thermal treatment or gamma irradiation. Suitable recoveries were obtained after pre-concentration of dilute solutions, at the ng/L level, of a mixture of pesticides, indicating the good performance of the materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, fast and low-cost methodology was optimized, seeking preparation of a crude pig liver esterase (PLE) concentrate. Basically, the method consisted of the following steps: liver homogenization, acetone washing, enzyme extraction and purification/concentration. Starting from 1 kg of fresh liver more than 200 kU of PLE suspension were obtained after 8 hours, at an estimated cost of US$0.21/kU. The PLE concentrate thus obtained was stable, showing 96-100% of the initial activity after 7 months in refrigerator at 4°C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports extraction yield and chemical characterization of the extracts obtained by high-pressure CO2 extraction of a cultivar of Ocimum basilicum L. The experiments were performed in the temperature range of 20 to 50 °C, from 100 to 250 atm of pressure. Chemical analyses were carried out by gas chromatography coupled to mass spectrometry, permitting to identify 23 compounds that were grouped into five chemical classes. Results showed that temperature and solvent density influenced positively the extraction yield. At 20 °C and 0.41 g cm-3 occurred a rise in the concentration of monoterpenes, oxygenated monoterpenes, sesquiterpenes and oxygenated sesquiterpenes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solvent extraction has been successfully applied to metal ion preconcentration and often meant the use of toxic organic diluents. However, regulatory pressure is increasingly focusing on the use and disposal of organic solvents, and thus the development of nonhazardous alternatives is important. In this review, we examine the application of aqueous biphasic systems (ABS) to extraction of ions, analyzing their potential and limitations and suggest that ABSs could be an efficient substitute for oil/water biphasic systems. ABSs are formed by mixing certain inorganic salts and water-soluble polymers, or by mixing two water-soluble polymers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gravimetric and Bailey-Andrew methods are tedious and provide inflated results. Spectrofotometry is adequate for caffeine analysis but is lengthy. Gas chromatography also is applied to the caffeine analysis but derivatization is needed. High performance liquid chromatography with ultraviolet detection (HPLC-UV) and reversed phase is simple and rapid for xanthine multianalysis. In HPLC-UV-gel permeation, organic solvents are not used. HPLC-mass spectrometry provides an unequivocal structural identification of xanthines. Capillary electrophoresis is fast and the solvent consumption is smaller than in HPLC. Chemometric methods offer an effective means for chemical data handling in multivariate analysis. Infrared spectroscopy alone or associated with chemometries could predict the caffeine content in a very accurate form. Electroanalytical methods are considered of low cost and easy application in caffeine analysis.