428 resultados para Absorção sonora
Resumo:
This work proposes an analytical procedure for direct determination of calcium, magnesium, manganese and zinc in buffalo milk by flame atomic absorption spectrometry (FAAS). Samples were diluted with a solution containing 10% (v/v) of water-soluble tertiary amines (CFA-C) at pH 8. For comparison, buffalo milk samples were digested with HNO3 and H2O2. According to a paired t-test, the results obtained in the determination of Ca, Mg, Mn and Zn in digested samples and in 10% (v/v) CFA-C medium were in agreement at a 95% confidence level. The developed procedure is simple, rapid, decrease the possibility of contamination and can be applied for the routine determination of Ca, Mg, Mn and Zn in buffalo milk samples without any difficulty caused by matrix constituents, such as fat content, and particle size distribution in the milk emulsion.
Resumo:
Mercury is a toxic metal used in a variety of substances over the course history. One of its more dubious uses is in dental amalgam restorations. It is possible to measure very small concentrations of this metal in the urine of exposed subjects by the cold vapor atomic absorption technique. The present work features the validation as an essential tool to confirm the suitability of the analytical method chosen to accomplish such determination. An initial analysis will be carried out in order to evaluate the environmental and occupational levels of exposure to mercury in 39 members of the auxiliary dental staff at public consulting rooms in the city of Araguaína (TO).
Resumo:
Chicken meat is largely consumed in human nutrition and it is produced in extremely large scale in some countries, including Brazil. In this work graphite furnace atomic absorption spectrometry was used for determination of arsenic in chicken and chicken production-related samples. These samples were digested employing a microwave-assisted procedure in closed vessels using a 7 mol L-1 nitric acid solution plus concentrated hydrogen peroxide. The concentration range of total As determined in chicken production-related samples varied from 1.30 to 29.8 mg kg-1 of As. The detection and quantification limits reached were 0.055 and 0.182 mg kg-1, respectively (n = 15).
Resumo:
Levels of Ca, Mg, Fe, Zn, Cu and Mn were determinated by FAAS in the tea and dry matter from senescent leaf from Montrichardia linifera, plant used in folk medicine Amazon. The content of these metals that are transferred of the leaf to the infusions have presented significant reductions, however, the Mn values in the infusion may exceed the tolerable daily intake (11 mg) if consumption of this tea is greater than 1.0 L per day. So the tea of senescent leaves of M. linifera may be considered as a toxic beverage and thus its use is not advised.
Resumo:
This paper describes the development of methods for the determination of Pb and Mn in fishes by GF AAS after solubilization with tetramethylamonium hidroxide. The optimization of the operational conditions and the choice of modifier were made using multivariated optimization. Analytical Figures of Merit were adequately to propose. The Limit of Quantification obtained were 150 and 18.5 µg kg-1 to Mn and Pb, respectively. No significant difference was found between the slope values obtained for the aqueous and standard addition calibration curves. The D.P.R. was always lower than 12% and the analysis of the SRM NRCC TORT2 showed 80-120% of recovery.
Resumo:
Systematic studies were undertaken in the intra zeolitic media to better understand the ability of zeolite type LTA in occluded nitrogen used in fertilizer and soil conditioning. We have measured the dry matter production from the cultivation of corn in a greenhouse for about 40 days, and also the amounts of nitrogen absorbed, retained and lost by leaching. The dry matter production in the cultivation with different concentrations of nitrogen occluded in the zeolite, was more efficient than the traditional fertilizer, which demonstrated better use of nitrogen to reduce leaching losses, which implies a possible reduction of costs for nitrogen.
Resumo:
The application of multivariate analysis to spectrophotometric (UV) data was explored for distinguishing extracts of cachaça woods commonly used in the manufacture of casks for aging cachaças (oak, cabreúva-parda, jatobá, amendoim and canela-sassafrás). Absorbances close to 280 nm were more strongly correlated with oak and jatobá woods, whereas absorbances near 230 nm were more correlated with canela-sassafrás and cabreúva-parda. A comparison between the spectrophotometric model and the model based on chromatographic (HPLC-DAD) data was carried out. The spectrophotometric model better explained the variance data (PC1 + PC2 = 91%) exhibiting potential as a routine method for checking aged spirits.
Resumo:
Two parallel tests were carried out to evaluate barium solubility in soils treated with barite under reducing conditions: one in leaching columns and another with potted plants cultivated with rice. Soils were treated with three doses of barite and kept at two humidity levels. The reduction (-200 mV) condition promoted an increase in barium in the geochemical fraction of higher liability, higher concentrations of barium in the leached extracts, and higher absorption by rice plants. As a result of increased uptake and accumulation of barium, the plants showed stunted growth
Resumo:
In this study, a method for determination of hexavalent chromium in aqueous samples using liquid-liquid microextraction (LLME) and detection by Flame Atomic Absorption Spectrometry (F AAS) was developed. The LLME procedure was based on the extraction of Cr (VI) by acetone at a sample pH of 1.2. The use of saturated ammonium sulphate solution allowed effective separation of the aqueous and organic phases and acetone extracted chromium. The sample pH, acetone volume and stirring time were optimized by a full factorial design.
Resumo:
Simple and sensitive procedures for the extraction/preconcentration of molybdenum based on vortex-assisted solidified floating organic drop microextraction (VA-SFODME) and cloud point combined with flame absorption atomic spectrometry (FAAS) and discrete nebulization were developed. The influence of the discrete nebulization on the sensitivity of the molybdenum preconcentration processes was studied. An injection volume of 200 µL resulted in a lower relative standard deviation with both preconcentration procedures. Enrichment factors of 31 and 67 and limits of detection of 25 and 5 µg L-1 were obtained for cloud point and VA-SFODME, respectively. The developed procedures were applied to the determination of Mo in mineral water and multivitamin samples.
Resumo:
This aim of this work was to compare two methods for copper determination in insulating oils from power transformers by GFAAS. The first method was extraction induced by emulsion breaking, which determined the preconcentration of copper in an aqueous solution and exhibited a limit of quantification of 0.27 µg L-1. Also, a second method based on the direct introduction of samples into GFAAS in the form of detergent emulsions, prepared with Triton X-114 and HNO3, was investigated. In this case, the limit of quantification was 1.7 µg L-1. Seven samples of used oils were successfully analyzed by both methods.
Resumo:
The phenanthridinone heterocyclic system has attracted considerable attention in recent years due to the diverse array of physical, chemical and pharmacological properties demonstrated by natural and synthetic derivatives. As a consequence there has been considerable development of synthetic methodology for the synthesis of this and related heterocyclic ring systems. The synthetic literature is discussed and is compared with a direct arylation methodology for the intramolecular cyclization of tertiary (2-iodo)benzoylamides to generate the biaryl bond of these compounds. The efficient methodology allowed the synthesis of a number of previously unknown phenanthridinone products. The photoluminescent properties of representative examples were characterized and it is proposed that the previously unknown compound 1s reveals dual fluorescence in a manner similar to the known compound 1r.
Resumo:
Este trabalho descreve uma revisão a respeito do emprego da técnica de espectrometria de absorção atômica simultânea em forno de grafite (SIMAAS) em determinações multielementares de elementos-traço em diferentes matrizes. Os principais parâmetros envolvidos e que devem ser considerados em medidas multielementares, tais como, fonte de radiação, geometria do forno, programa de aquecimento e natureza e quantidade de modificador químico, são descritos.
Resumo:
A influência de digeridos e suspensões de açúcar no comportamento térmico de As usando Pd(NO3)2, Pd(NO3)2 + Mg(NO3)2, and Ni(NO3)2 como modificadores químicos foi investigada. Influência de 0,2%, 5%, 10% e 35% (v/v) HNO3 na calibração (1,00 - 10,0 µg As L-1) também foi feita. Um volume de 20 µL de amostra mais 5 µL Pd ou 5 µL Pd + 3 µL Mg, ou 20 µL Ni foi injetado no atomizador do GF AAS. Para cada modificador, temperaturas de pirólise e atomização foram avaliadas por meio de curvas de pirólise e de atomização, respectivamente. Para suspensão de açúcar, temperaturas de pirólise e atomização (Tp, Ta) obtidas foram: sem modificador (400° C, 2000° C); Pd (1400° C, 2200° C); Pd/Mg (1400° C, 2200° C) e Ni (1600° C, 2200° C). Os valores para digeridos de açúcar foram: sem modificador (400° C, 2200° C); Pd (1400° C, 2200° C); Pd/Mg (1400° C, 2200° C) e Ni (600° C, 2200° C). Paládio foi selecionado como o melhor modificador químico. O tempo de vida do tubo de grafte foi de aproximadamente 350 queimas, o RSD (n = 12) para uma amostra típica contendo 5,52 µg As L-1 foi < 2,2% e o limite de detecção foi 2,4 pg As. Recuperações entre 80 e 92% foram encontradas.
Resumo:
Este trabalho propõe um método simples, rápido e confiável para determinação direta e simultânea de Al, As, Fe, Mn e Ni em cachaça por espectrometria de absorção atômica em forno de grafite (GFAAS). A superfície superior da plataforma do tubo de grafite foi revestida com filme à base de tungstênio (WxCyOz).O programa de aquecimento otimizado (temperatura, tempo de rampa, tempo de patamar) foi o seguinte: secagem 1 (100ºC, 5 s, 5 s); secagem 2 (120ºC, 5 s, 5 s); pirólise (1300ºC, 10 s, 30 s); atomização (2200ºC, 1 s, 6 s) e limpeza (2550ºC, 1 s, 3s). Os desvios padrões relativos (n=3) foram < 4,4%, < 0,7%, < 11%, < 6,0%, < 1,2% para os elementos Al, As, Fe, Mn e Ni, respectivamente. A exatidão foi avaliada por meio de testes de adição e recuperação dos analitos em 8 amostras de cachaças comerciais, e as recuperações situaram-se nos seguintes intervalos: 80 - 105% (Al), 81 - 92% (As), 82 - 108% (Fe), 83 - 106% (Mn), 83 - 108% (Ni). Os limites de detecção calculados foram 9,7 µg L-1 Al, 2,3 µg L-1 As, 12 µg L-1 Fe, 14 µg L-1 Mn e 0,8 µg L-1 Ni.