324 resultados para concentração de íons plasmáticos
Resumo:
The aquatic humic substances (AHS) investigated in this study were conventionally isolated from Rio Negro waters - Amazonas State/Brazil by means of the collector XAD 8. A special five-stage tangential-flow ultrafiltration device was used for analytical fractionation of AHS. The fractionation patterns (6 fractions each) showed that metal traces remaining in AHS after their XAD 8 isolation have different size distributions. For instance, the major percentage of traces of Ni, Cu, Zn, Cd and Pb (determined using ICP-AES) was preferably complexed by molecules with relatively high molecular size (30-100 kDa) and the following complexation order was characterized: F2 >> F1 = F4 = F5 > F3 > F6. Moreover, the species formed between AHS and metals prepared by spiking, showed distribution patterns changing as a function of the complexation time (ageing process), indicating a slow transformation process and an inner rearrangements in the binding sites within the AHS molecules.
Resumo:
This article shows the usefulness of a website to explain the concepts, operational events, vacuum system, applications and an experimental sequence of the Fourier Transform Ion Ciclotron Resonance Mass Spectrometry technique (http://143.107.46.113/icr/icrj.html).
Resumo:
The reaction between hydroxy-terminated polybutadiene and isophorone diisocyanate constitutes the base of the curing process of the most composite solid propellant used in the propulsion of solid rocket propellant. In this work, differential scanning calorimetry and viscosity measurements were used to evaluate the effect of the ferric acetylacetonate catalyst concentration on the reaction between HTBR and IPDI. These analyses show one exotherm, which shifts to lower temperatures as the catalyst concentration increases. The viscosity analyses show that the increase of temperature causes, at first, a reduction in the mixture viscosity, reaching a minimum range called gelification region (increasing the crosslinking density).
Resumo:
The aim of this work was to propose two different didactic experiments, which can be used in practical classes of analytical chemistry courses. More flexible experiments related to the theme, giving some options to the instructor are proposed. In this way, the Experiment 1 was divided in two parts. In the first one, the visualization of two distinct phases separation is emphasized: the rich and the poor phases in surfactant. In the second part, the metal pre-concentration (Co as example) is emphasized. The Experiment 2 has three different parts. In the first one, the complex formation is pointed out, in the second one, the pH influence is shown and in the last one, the influence of the complexation time is demonstrated.
Resumo:
A flow injection spectrophotometric procedure was developed for the determination of metamizol in pharmaceutical formulations. The system is based on the reaction between metamizol and triiodide generated in the system by mixing iodate and iodide-starch solutions. The absorbance of triiodide-starch complex giving a steady-state baseline value which was monitored at 580 nm. The inverse peaks caused by metamizol samples were measured and there was a direct relationship between absorbance decreasing and metamizol concentration from 1.4 x 10-4 to 7.0 x 10-4 mol L-1. The RSD was 0.45 % for a metamizol solution 4.2 x 10-4 mol L-1 (n = 10) with a detection limit (three-fold blank standard deviation/slope) of 6.0 x 10-5 mol L-1 The feasibility of the system was demonstrated for the determination of metamizol in commercial samples with sixty results obtained per hour. The results obtained for metamizol in pharmaceutical formulations using the proposed flow procedure and those obtained using an iodimetric procedure are in agreement at the 95% confidence level and within an acceptable range of error.
Resumo:
A method for determination of lead and cadmium in aqueous samples using solvent microextraction and dithizone as complexing agent with FAAS was developed. Solvent microextraction parameters were optimized. The effect of foreign ions on the extraction yields was studied. The extraction was carried out until the aqueous to organic phase ratio achieved a 250 fold preconcentration of metals. For preconcentration times of 4 min the 3sigma detection limits, relative standard deviations (n=7) and linear calibration ranges were 1.6 mug L-1, 5.8% and 10.0 -- 80.0 mug L-1 for lead and 11.1 ng L-1, 5.9% and 0.3 -- 3.0 mug L-1 for cadmium, respectively. The solvent microextraction procedure presented here was applied to the determination of lead and cadmium in natural waters.
Resumo:
An automatic flow injection procedure for spectrophotometric aluminium determination in purified water and solutions containing high salts concentrations used for hemodyalisis treatment was developed. The method was base on reaction of Al3+ with cianine eriochrome R (ECR) after preconcentration using the AG50W-X8 cationic-exchange resin. Elution was carried out using a 1 % (m/v) calcium chloride solution. The manifold comprised an automatic proporcional injector controlled by a computer equipped with an eletronic interface and software written in QuicBASIC 4.5 with facilities to control the injector and perform data acquisition. Samples with concentration ranging from 4.96 to 19.90 µg L-1 Al were analyzed and recoveries between 88 and 113% were obtained by using the standard addition method. Other profitable analytical characteristics such as a relative standard deviation 1.3 % (n = 10) for a typical sample 14.5 µg L-1 Al, a linear response ranging up to 60.0 µg L-1Al, and a sampling throughput of 10 determinations per hour were achieved. A detection limit of 4.2 µg L-1 Al was estimated as suggested by IUPAC.
Resumo:
The aim of this work was to explore the possibility of the application of a non-ionic resin obtained by impregnation of Alizarin Red S (VAS) in Amberlite XAD-7 for manganese, copper and zinc separation and preconcentration in saline matrices. For these system, the metals were quantitatively retained, in the pH range 8.5-10.0, by using 0.50 g of solid phase, stirring time of five minutes and a total mass up to 200 mug of each cation. The sorbed elements were subsequently eluted and a fifty-fold, ten-fold and ten-fold preconcentration factor for to Zn, Cu and Mn were obtained, respectively.
Resumo:
In the last three decades carbonyl compounds, aldehydes and ketones, have received a great deal of attention due to their strong influence on photochemical smog formation and their recognized adverse human health effects. Carbonyl compounds are directly emitted into the atmosphere by combustion sources and also produced from photochemical oxidation of hydrocarbons and other organic compounds. In this paper it is presented a general overview about the carbonyl compounds sources, reactivity, concentration levels and toxicological effects.
Resumo:
This paper describes the development of a methodology for solid phase extraction (SPE) and pre-concentration of nitrosamines from aqueous samples using granular activated charcoal as stationary phase. micelar electrokinetic capillary Chromatography (MEKC) was used for the separation and identification of the nitrosamines in the extracts. Using a sample with 50 µg l-1 of each nitrosamines standards (dimethylnitrosamine, DMN; diethylnitrosamine, DEN; N-nitrosopyrrolidine, NPYR; N-nitrosopiperidine, NPIP; N-nitrosomorpholine, NMOR), the methodology showed a range of recuperation from 29 to 107% with a linear zone between 10 and 500 µg l-1. The developed methodology can be applicable to the determination of these analytes in different aqueous samples.
Resumo:
Dilutions of methylmetacrylate ranging between 1 and 50 ppm were obtained from a stock solution of 1 ml of monomer in 100 ml of deionised water, and were analyzed by an absorption spectrophotometer in the UV-visible. Absorbance values were used to develop a calibration model based on the PLS, with the aim to determine new sample concentrations. The number of latent variables used was 6, with the standard errors of calibration and prediction found to be 0,048 ml/100 ml and 0,058 ml/100 ml. The calibration model was successfully used to calculate the concentration of monomer released in water, where complete dentures were kept for one hour after polymerization.
Resumo:
With the aim of studying the interaction of fast electrons with solid surfaces we have developed an experimental set-up based on electron stimulated desorption (ESD) coupled to time-of-flight (TOF) mass spectrometry. Poly(methyl methacrylate) and poly(vynil chloride) samples have been irradiated by a pulsed electron beam of 1.2 keV and 0.18 µs FWHM. The results show that H+ is the main ionic species to desorb after electron bombardment. In addition, other ionic fragments were also observed and assigned. These results show the potentiality of this technique in the study of ESD of polymers.
Resumo:
European Directive (98/83/CE), compulsory after 2008, states that bromate in drinking water must be controlled at levels below 10 mg L-1. Supporting implementation of the Directive, the European Comission has established project SMT4-CT96 2134, in collaboration with various european institutions, aiming at the identification of the interferents to the current analytical method (Ionic Chromatography with Conductimetric Detection - IC/CD), their removal and the automation of pre-treatment and injection steps, as well as the development of alternative methods. EPAL, responsible for the water supply to a great deal of Portuguese regions, has taken steps to meet these requirements. Although not part of such project, this work (the result of a project conducted under a protocol of collaboration between EPAL SA and FCUL - Faculty of Sciences, University of Lisbon), reports on studies of usefulness to laboratories planning to monitor bromate in ozone treated waters, in conditions different from those described in EPA 300.1. Simultaneous determination of bromide is justified by its role as bromate precursor.
Resumo:
The aim of this study was the determination of the critical micelle concentration (CMC) of the sodium dodecyl sulfate (SDS) surfactant using spectroscopic and conductimetric determinations and to compare these methodologies in the determination of the CMC of different humic acids (HA). The CMC obtained by conductimetric determination was satisfactory. By spectroscopic determination two values of the CMC were obtained for HA. These values can be to due the intra and intermolecular interactions in the HA structure.
Resumo:
This article gives an overview of polymer materials used for lead separation and preconcentration. Different kinds of polymer resins, commercial or not, are cited as well as the most used functional groups attached to polymer backbones. The synthesis of these resins and conditions of lead adsorption and elution are remarked. The influence of the porous structure of the polymer on the resines performance is described as well as the use of spacer arms.