268 resultados para Right-heart Catheterization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiovascular diseases are the leading causes of mortality and morbidity in Brazil. The primary and secondary preventions of those diseases are a priority for the health system and require multiple approaches to increase their effectiveness. Biomarkers are tools used to more accurately identify high-risk individuals, to speed the diagnosis, and to aid in treatment and prognosis determination. This review aims to highlight the importance of biomarkers in clinical cardiology practice, and to raise relevant points of their use and the promises for the coming years. This document was divided into two parts, and this first one discusses the use of biomarkers in specific cardiomyopathies and heart failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Cardiovascular urgencies are frequent reasons for seeking medical care. Prompt and accurate medical diagnosis is critical to reduce the morbidity and mortality of these conditions.Objective:To evaluate the use of a pocket-size echocardiography in addition to clinical history and physical exam in a tertiary medical emergency care.Methods:One hundred adult patients without known cardiac or lung diseases who sought emergency care with cardiac complaints were included. Patients with ischemic changes in the electrocardiography or fever were excluded. A focused echocardiography with GE Vscan equipment was performed after the initial evaluation in the emergency room. Cardiac chambers dimensions, left and right ventricular systolic function, intracardiac flows with color, pericardium, and aorta were evaluated.Results:The mean age was 61 ± 17 years old. The patient complaint was chest pain in 51 patients, dyspnea in 32 patients, arrhythmia to evaluate the left ventricular function in ten patients, hypotension/dizziness in five patients and edema in one patient. In 28 patients, the focused echocardiography allowed to confirm the initial diagnosis: 19 patients with heart failure, five with acute coronary syndrome, two with pulmonary embolism and two patients with cardiac tamponade. In 17 patients, the echocardiography changed the diagnosis: ten with suspicious of heart failure, two with pulmonary embolism suspicious, two with hypotension without cause, one suspicious of acute coronary syndrome, one of cardiac tamponade and one of aortic dissection.Conclusion:The focused echocardiography with pocket-size equipment in the emergency care may allow a prompt diagnosis and, consequently, an earlier initiation of the therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our knowledge regarding the anatomophysiology of the cardiovascular system (CVS) has progressed since the fourth millennium BC. In Egypt (3500 BC), it was believed that a set of channels are interconnected to the heart, transporting air, urine, air, blood, and the soul. One thousand years later, the heart was established as the center of the CVS by the Hippocratic Corpus in the medical school of Kos, and some of the CVS anatomical characteristics were defined. The CVS was known to transport blood via the right ventricle through veins and the pneuma via the left ventricle through arteries. Two hundred years later, in Alexandria, following the development of human anatomical dissection, Herophilus discovered that arteries were 6 times thicker than veins, and Erasistratus described the semilunar valves, emphasizing that arteries were filled with blood when ventricles were empty. Further, 200 years later, Galen demonstrated that arteries contained blood and not air. With the decline of the Roman Empire, Greco-Roman medical knowledge about the CVS was preserved in Persia, and later in Islam where, Ibn Nafis inaccurately described pulmonary circulation. The resurgence of dissection of the human body in Europe in the 14th century was associated with the revival of the knowledge pertaining to the CVS. The main findings were the description of pulmonary circulation by Servetus, the anatomical discoveries of Vesalius, the demonstration of pulmonary circulation by Colombo, and the discovery of valves in veins by Fabricius. Following these developments, Harvey described blood circulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Radiofrequency ablation is the standard non-pharmacological treatment for arrhythmias in pediatric patients. However, arrhythmias and their associated causes have particular features in this population.Objective:To analyze the epidemiological characteristics and findings of electrophysiological diagnostic studies and radiofrequency ablations in pediatric patients referred to the Electrophysiology Unit at Instituto de Cardiologia do Rio Grande do Sul, in order to characterize the particularities of this population.Methods:Cross-sectional study with 330 electrophysiological procedures performed in patients aged less than 20 years between June 1997 and August 2013.Results:In total, 330 procedures (9.6% of the overall procedures) were performed in patients aged less than 20 years (14.33 ± 3.25 years, age range 3 months to 19 years), 201 of which were males (60.9%). A total of 108 (32.7%) electrophysiological diagnostic studies were performed and of these, 48.1% showed abnormal findings. Overall, 219 radiofrequency ablations were performed (66.3%) with a success rate of 84.8%. The presence of an accessory pathway was the most prevalent finding, occurring in 158 cases (72.1%), followed by atrioventricular nodal reentrant tachycardia (16.8%), typical atrial flutter (3.1%) and extrasystoles originating from the right ventricular outflow tract (2.7%). Three patients developed complications during ablation (1.4%). Among congenital heart diseases, which occurred in 51 (15.4%) patients, atrial sept defect was the most frequent (27.4%), followed by ventricular sept defect (25.4%) and Ebstein's anomaly (17.6%).Conclusion:Electrophysiological study and radiofrequency ablation are effective tools for diagnosis and treatment of arrhythmias in the pediatric population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Heart transplantation is considered the gold standard therapy for the advanced heart failure, but donor shortage, especially in pediatric patients, is the main limitation for this procedure, so most sick patients die while waiting for the procedure.Objective:To evaluate the use of short-term circulatory support as a bridge to transplantation in end-stage cardiomyopathy.Methods:Retrospective clinical study. Between January 2011 and December 2013, 40 patients with cardiomyopathy were admitted in our Pediatric Intensive Care Unit, with a mean age of 4.5 years. Twenty patients evolved during hospitalization with clinical deterioration and were classified as Intermacs 1 and 2. One patient died within 24 hours and 19 could be stabilized and were listed. They were divided into 2 groups: A, clinical support alone and B, implantation of short-term circulatory support as bridge to transplantation additionally to clinical therapy.Results:We used short-term mechanical circulatory support as a bridge to transplantation in 9. In group A (n=10), eight died waiting and 2 patients (20%) were transplanted, but none was discharged. In group B (n=9), 6 patients (66.7%) were transplanted and three were discharged.The mean support time was 21,8 days (6 to 984h). The mean transplant waiting list time was 33,8 days. Renal failure and sepsis were the main complication and causeof death in group A while neurologic complications were more prevalent en group B.Conclusion:Mechanical circulatory support increases survival on the pediatric heart transplantation waiting list in patients classified as Intermacs 1 and 2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Isolated congenital atrioventricular block (CAVB) is a rare condition with multiple clinical outcomes. Ventricular remodeling can occur in approximately 10% of the patients after pacemaker (PM) implantation.Objectives:To assess the functional capacity of children and young adults with isolated CAVB and chronic pacing of the right ventricle (RV) and evaluate its correlation with predictors of ventricular remodeling.Methods:This cross-sectional study used a cohort of patients with isolated CAVB and RV pacing for over a year. The subjects underwent clinical and echocardiographic evaluation. Functional capacity was assessed using the six-minute walk test. Chi-square test, Fisher's exact test, and Pearson correlation coefficient were used, considering a significance level of 5%.Results:A total of 61 individuals were evaluated between March 2010 and December 2013, of which 67.2% were women, aged between 7 and 41 years, who were using PMs for 13.5 ± 6.3 years. The percentage of ventricular pacing was 97.9 ± 4.1%, and the duration of the paced QRS complex was 153.7 ± 19.1 ms. Majority of the subjects (95.1%) were asymptomatic and did not use any medication. The mean distance walked was 546.9 ± 76.2 meters and was strongly correlated with the predicted distance (r = 0.907, p = 0.001) but not with risk factors for ventricular remodeling. (Arq Bras Cardiol. 2014; [online].ahead print, PP.0-0)Conclusions:The functional capacity of isolated CAVB patients with chronic RV pacing was satisfactory but did not correlate with risk factors for ventricular remodeling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Congenital heart defects (CHD) are the most prevalent group of structural abnormalities at birth and one of the main causes of infant morbidity and mortality. Studies have shown a contribution of the copy number variation in the genesis of cardiac malformations.Objectives:Investigate gene copy number variation (CNV) in children with conotruncal heart defect.Methods:Multiplex ligation-dependent probe amplification (MLPA) was performed in 39 patients with conotruncal heart defect. Clinical and laboratory assessments were conducted in all patients. The parents of the probands who presented abnormal findings were also investigated.Results:Gene copy number variation was detected in 7/39 patients: 22q11.2 deletion, 22q11.2 duplication, 15q11.2 duplication, 20p12.2 duplication, 19p deletion, 15q and 8p23.2 duplication with 10p12.31 duplication. The clinical characteristics were consistent with those reported in the literature associated with the encountered microdeletion/microduplication. None of these changes was inherited from the parents.Conclusions:Our results demonstrate that the technique of MLPA is useful in the investigation of microdeletions and microduplications in conotruncal congenital heart defects. Early diagnosis of the copy number variation in patients with congenital heart defect assists in the prevention of morbidity and decreased mortality in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Ischemic postconditioning (IPost) is a method of protecting the heart against ischemia-reperfusion (IR) injury. However, the effectiveness of IPost in cases of ischemic heart disease accompanied by co-morbidities such as hypothyroidism remains unclear. Objective: The aim of this study was to determine the effect of IPost on myocardial IR injury in hypothyroid male rats. Methods: Propylthiouracil in drinking water (500 mg/L) was administered to male rats for 21 days to induce hypothyroidism. The hearts from control and hypothyroid rats were perfused in a Langendorff apparatus and exposed to 30 min of global ischemia, followed by 120 min of reperfusion. IPost was induced immediately following ischemia. Results: Hypothyroidism and IPost significantly improved the left ventricular developed pressure (LVDP) and peak rates of positive and negative changes in left ventricular pressure (±dp/dt) during reperfusion in control rats (p < 0.05). However, IPost had no add-on effect on the recovery of LVDP and ±dp/dt in hypothyroid rats. Furthermore, hypothyroidism significantly decreased the basal NO metabolite (NOx) levels of the serum (72.5 ± 4.2 vs. 102.8 ± 3.7 μmol/L; p < 0.05) and heart (7.9 ± 1.6 vs. 18.8 ± 3.2 μmol/L; p < 0.05). Heart NOx concentration in the hypothyroid groups did not change after IR and IPost, whereas these were significantly (p < 0.05) higher and lower after IR and IPost, respectively, in the control groups. Conclusion: Hypothyroidism protects the heart from IR injury, which may be due to a decrease in basal nitric oxide (NO) levels in the serum and heart and a decrease in NO after IR. IPost did not decrease the NO level and did not provide further cardioprotection in the hypothyroid group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Matrix metalloproteinases (MMPs) are a family of enzymes important for the resorption of extracellular matrices, control of vascular remodeling and repair. Increased activity of MMP2 has been demonstrated in heart failure, and in acutely decompensated heart failure (ADHF) a decrease in circulating MMPs has been demonstrated along with successful treatment. Objective: Our aim was to test the influence of spironolactone in MMP2 levels. Methods: Secondary analysis of a prospective, interventional study including 100 patients with ADHF. Fifty patients were non-randomly assigned to spironolactone (100 mg/day) plus standard ADHF therapy (spironolactone group) or standard ADHF therapy alone (control group). Results: Spironolactone group patients were younger and had lower creatinine and urea levels (all p < 0.05). Baseline MMP2, NT-pro BNP and weight did not differ between spironolactone and control groups. A trend towards a more pronounced decrease in MMP2 from baseline to day 3 was observed in the spironolactone group (-21 [-50 to 19] vs 1.5 [-26 to 38] ng/mL, p = 0.06). NT-pro BNP and weight also had a greater decrease in the spironolactone group. The proportion of patients with a decrease in MMP2 levels from baseline to day 3 was also likely to be greater in the spironolactone group (50% vs 66.7%), but without statistical significance. Correlations between MMP2, NT-pro BNP and weight variation were not statistically significant. Conclusion: MMP2 levels are increased in ADHF. Patients treated with spironolactone may have a greater reduction in MMP2 levels.