208 resultados para Tucuruí Reservoir


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The supply of drinking water in the Metropolitan Area of São Paulo City has been a great and serious challenge in the latest years. This work demonstrates the viability of the evaluation of the degree of contamination of the water reservoirs using analytical procedures, which allow the analysis of several compounds at relatively low cost: stripping square wave voltammetry (SSWV) and capillary zone electrophoresis with contactless conductivity detection (CZE-CCD). The results of ionic composition indicated significant contamination of the Guarapiranga water system by human activities on the reservoir banks. In fact, the Guavirutuba and Itupu streams presented high concentrations of phosphate and ammonium ions. This can be directly related to misuse and unruled occupation of the soil and precarious sanitary infrastructure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sediment samples from Tietê river were submitted to chemical and sequential extractions of heavy metals (Cd, Cr, Cu, Ni, Pb and Zn). It was followed a single extraction by using 0.1 mol L-1 hydrochloric acid and a sequential procedure to evaluate possible chemical associations described as exchangeable, carbonate, reducible oxides, sulfide, organic matter and residual fractions. High concentrations of heavy metals were determined at Pirapora reservoir, which is closer to the Metropolitan Area of São Paulo while for Barra Bonita reservoir, the results showed low concentrations for such elements. Acid volatile sulfides, grain size distribution and carbon contents were also determined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Last decade Brazilian rivers experimented progressive biofouling of Limnoperna fortunei communities and Cordylophora caspia hydroids. The microhabitat is so favorable that in around 1.5 years L. fortunei increased from 0.39 to nearby 149,000 units/m². Ten Portland cement mortar samples were produced with 1: 3.5: 0.4 dosages and installed for 1 year at Salto Caxias Brazilian Power Plant reservoir in 0.5 m and 1.0 m deep to investigate the biofouling influence on hydraulic civil structures. SEM, EDS, visual investigation and XRF results indicate none direct chemical interrelationships between L. fortunei and the mortar samples. However C. caspia diminished the mortar surface resistance and caused cement paste leaching.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work describes a low-cost electrochemical "wall-jet" detector for flow analysis. The electrolytic solution enters into the cell through a tube of stainless steel (200 to 300 µm i.d), reaching to the center of the working electrode perpendicularly and then being mixed to the remaining solution in the cell, which flows under atmospheric pressure into a waste reservoir. The proposed electrochemical detector can be used with any type of working electrode, from commercial to home-made, such as glassy carbon and metallic electrodes (modified or unmodified), which enlarge the applications of the electrochemical detector.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

TitDrop II, a practice low-cost titrator based on drop counting is proposed. A microcomputer counts drops in an opto-switch and it receives pH values from a commercial pHmeter with RS-232 serial port. The volume of drops must kept constant and the amount of base in each drop is obtained by standardization in the titrator. A linear behavior between height of reservoir of titrant and drop frequency was observed, but there is no influence of low height on drop volume. Acetic acidity in samples of vinager was compared with volumetric titration, and deviation between -2.6 to 3.9% was observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrostatic phenomena were discovered long ago but their interpretation according to well-established atomic-molecular theory is still lacking. As a result, electrostatic phenomena are often irreproducible and uncontrolled, causing serious practical problems. Highly reproducible recent experimental results on electrostatic charging from this and other laboratories are reviewed in this work, together with a description of the relevant but not so usual Kelvin probe and Faraday cup techniques. These results support a new model for electrostatic charging of dielectrics and insulated metals, based on the role of moist atmosphere as a charge reservoir.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A portable microcontrolled system is proposed to monitor conductivity, temperature and pH in on-line, in situ and remote way from a water reservoir faraway 200 m. The system comprises two modules: one for data reception (located in laboratory) and another for data acquisition/transmission (located near water reservoir). It uses a microcontroller and a transceiver to remote data transmission/reception by radio frequency. Variations of water parameters were simultaneously monitored without interruption during a period of ten hours with a relative error about 4.0 %. The developed system showed simple, stable, accurate, robust and low-cost to determine parameters of water in field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to evaluate the bioaccumulation of macronutrients and heavy metals in the golden mussel according to its collection site and seasonality in the aquaculture area of the reservoir from April/2009 to March/2010. There is no difference (p > 0.05) in the concentration of metals with respect to the point of collection. The concentrations of Cu, Fe, Mn, Zn, Cd and Pb were higher (p < 0.05) in spring and summer than in fall and winter. Values of the heavy-metal pollution index (MPI) for collection point and seasonality indicate environmental contamination in the aquaculture area.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reservoir geochemistry has been effectively used to evaluate compositional heterogeneity in petroleum reservoirs by employing oil fingerprinting technique to assess reservoir continuity, primarily in paraffin oil accumulations. In-reservoir biodegradation has resulted in vast deposits of heavy oils globally; therefore, the application of reservoir geochemistry to such accumulations becomes necessary. We recommend the use of pentacyclic terpanes instead of lower molecular compounds, which are less resistant to biodegradation. Using oil fingerprinting technique in this novel way enabled the differentiation of oil composition among sedimentary facies of tar sands (Pirambóia Formation, Paraná Basin).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nutrient levels in water reservoirs have been increasing over the years worldwide and fish farming is one of the activities with the potential to cause negative impacts on these environments. Thus, the sedimentation of the main nutrients was evaluated in a reservoir as well as the contribution of aquaculture in raising these rates. The results indicated a significant difference for all nutrients, with higher concentrations in areas near the fish farming, and lower levels in more distant regions. Therefore, assessments that focus only on the water column do not reflect the true impact of this activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bioaccumulation of Ag, Al, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb and Zn was determined in the gills and liver of Cyprinus carpio and related to concentrations in the sediment and water of the Alagados Reservoir, Ponta Grossa/Paraná. Cd and Fe exceeded the legal limit for water. Fe was the most abundant metal in the reservoir's water and sediment. The metals in the sediment were below the level of probable adverse effects on biota. There were no significant differences between sampling sites for water and sediment. Liver and gills had higher concentrations of Al, Fe and Zn, with a significant increase in Al (P > 0.05) compared to the increase in weight and size of the specimens. Statistically, gills showed higher concentrations of Al, Cd, Co, Cr, Mn and Zn and liver higher concentrations of Cu and Fe. Co, Cu, Fe, Mn and Zn showed significant differences (P < 0.01) between the organs. The bioaccumulation factors (BAF) showed that the interaction of water with gills promotes greater accumulation of metals in this organ. Despite the low concentrations in the reservoir, bioaccumulation of metals in gills and liver of C. carpio occurs by its interaction with contaminated water and sediment, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Measurements of parameters expressed in terms of carbonic species such as Alkalinity and Acidity of saline waters do not analyze the influence of external parameters to the titration such as Total free and associated Carbonic Species Concentration, activity coefficient, ion pairing formation and Residual Liquid Junction Potential in pH measurements. This paper shows the development of F5BC titration function based on the titrations developed by Gran (1952) for the carbonate system of natural waters. For practical use, samples of saline waters from Pocinhos reservoir in Paraiba were submitted to titration and linear regression analysis. Results showed that F5BC involves F1x and F2x Gran functions determination, respectively, for Alkalinity and Acidity calculations without knowing "a priori" the endpoint of the titration. F5BC also allows the determination of the First and Second Apparent Dissociation Constant of the carbonate system of saline and high ionic strength waters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Understanding hydrosedimental behavior of a watershed is essential for properly managing and using its hydric resources. The objective of this study was to verify the feasibility of the alternative procedure for the indirect determination of the sediment key curve using a turbidimeter. The research was carried out on the São Francisco Falso River, which is situated in the west of the state of Paraná on the left bank of ITAIPU reservoir. The direct method was applied using a DH-48 sediment suspended sampler. The indirect method consisted of the use of a linigraph and a turbidimeter. Based on the results obtained, it was concluded that the indirect method using a turbidimeter showed to be fully feasible, since it gave a power function-type mathematical model equal of the direct method. Furthermore, the average suspended sediment discharge into the São Francisco Falso River during the 2006/2007 harvest was calculated at 7.26 metric t day-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The state of Ceará, Brazil, has 75% of its area covered by Brazilian semiarid, with its peculiar features. In this state, the dams are constituted in water structure of strategic importance, ensuring, both in time and space, the development and supply of water to population. However, construction of reservoirs results in various impacts that should be carefully observed when deciding on their implementation. One of the impacts identified as negative is the increased evaporation, which constitutes a major component of water balance in reservoirs, especially in arid regions. Several methods for estimating evaporation have been proposed over time, many of them deriving from the Penman equation. This study evaluated six different methods for estimating evaporation in order to determine the most suitable for use in hydrological models for water balance in reservoirs in the state of Ceará. The tested methods were proposed by Penman, Kohler-Nordenson-Fox, Priestley-Taylor, deBruim-Keijman, Brutsaert-Stricker and deBruim. The methods presented good performance when tested for water balance during the dry season, and the Priestley-Taylor was the most appropriate, since the data from de simulated water balance with evaporation estimated by this method were the closest of the water balance data observed from measures of reservoir level and the elevation-volume curve provided by the Company of Management of Water Resources of the state of Ceará - COGERH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to identify the relation between the evapotranspirometer demand and the supply of water from local rainfall, evaluating the possibility of using water excess for irrigation of Green Roofs in the State of Mato Grosso, in Brazil. The study was done using a series of historical data provided by the National Institute of Meteorology (INMET - Instituto Nacional de Meteorologia) which has official climatological stations in 12 cities and regions of the State. The evapotranspiration values were obtained by the Penman-Monteith method and by the Climatic Water Balance (CWB) by the Thornthwaite and Mather method using Available Water Capacity (AWC) of 12mm. With the CWB the excess and deficit were calculated, which were used for the estimative of the volume and area of a reservoir as a function of a collector area of a roof of 100m² and the volume of supplementary water for irrigation. With the obtained results, it was found that in most investigated regions of the State the use of green roofs is not compromised by the water deficiency. On the other hand, the use of a reservoir to accumulate the rain water excess may be impractical, because it requires a considerable area for installation and also because of the high cost of the land.