656 resultados para Teste ELISA-IgM


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay (ELISA) for measles antibodies was compared with Plaque Neutralization (PRN), Haemagglutination inhibition (HI) and Fluorescent antibody (IFA) tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%). IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No diagnóstico sorológico da doença de Chagas podem ser encontradas acentuadas divergências mesmo entre laboratórios de grande experiência. Para a padronização de um teste imunoenzimático destinado primariamente à seleção de doadores de sangue foram cuidadosamente escolhidos painéis de soros que se buscaram como representativos das populações de chagásicos e de não chagásicos. Produzido para máxima sensibilidade e estabilidade, o novo reagente (bioELISA - cruzi*) foi testado em 1648 soros, com diagnóstico clínico de doença de Chagas em 219 e de outras afecções em 104. O teste foi comparado com testes já bem padronizados, de imunofluorescência (IF) e de hemaglutinação (HA), em 1325 soros. O limiar de reatividade (cut off), estabelecido como ideal, foi indicado nos testes pela absorbância de um soro de reatividade mínima. A sensibilidade do teste imunoenzimático foi de 0,9954 e a especificidade, como conegatividade, de 0,9969. Não foram vistos resultados falso-positivos em casos de sífilis, toxoplasmose, mononucleose e de soros com altos títulos de anti-estreptolisina 0, mas foram encontrados em 5 de 15 casos de leishmaniose tegumentar, 10 de 24 casos de calazar, 1 de 15 casos de artrite reumatóide e 1 de 12 casos de lupus eritematoso sistêmico. Os altos índices de sensibilidade em chagásicos e de especificidade na população geral, traduzem a elevada confiabilidade do teste para triagem de doadores de sangue e para a confirmação de suspeita clínica de doença de Chagas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com o objetivo de determinar a prevalência da infecção pelo Citomegalovírus (CMV) em pacientes com AIDS, bem como relacionar os achados clínico-virológicos decorrentes desta infecção com as repercussões anatomopatológicas, estudamos 50 pacientes adultos atendidos entre abril de 1986 a junho de 1987, em dois hospitais públicos de São Paulo (HSP e HSPE). Estes pacientes foram acompanhados clínica e laboratorialmente, por período médio de 2 meses com coletas seriadas de sangue, urina e saliva. Foram realizados isolamento do CMV em monocamadas de fibroblastos humanos e testes sorológicos de Imunofluorescência Indireta (IFI-IgG/IgM) e Reação Imunoenzimática (ELISA-IgG). No momento da admissão no estudo 20% (10/50) dos pacientes apresentavam anticorpos IgM CMV específicos e 100% (50/50) deles anticorpos IgG (IFI). Durante o acompanhamento, 5 pacientes inicialmente IgM negativos tornaram-se IgM positivos, sugerindo reativação ou reinfecção pelo CMV. O CMV foi isolado de sangue periférico em 12,5%, da urina em 23,2%, da saliva em 21,9% dos pacientes. Exames anatomopatológicos foram realizados em 24 pacientes, correspondendo a 60% dos pacientes que evoluiram para óbito durante o período de estudo. Corpúsculos de inclusão citomegálica característicos foram observados em 50% das necrópsias, sendo o aparelho digestivo, pulmões e supra-renais os sítios mais acometidos. Não se observou uma relação estatisticamente significante entre os achados clínicos e os achados virológicos e anatomopatológicos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Para evaluar la utilidad del método de recolección de muestras de sangre en papel de filtro para la detección de anticuerpos anti-dengue mediante un ELISA de Inhibición recientemente desarrollado en nuestro laboratorio, se realizó una toma simultánea de muestras de sangre en papel de filtro y de suero, de donantes de Banco de Sangre. Ambas muestras fueron conservadas a -20ºC y probadas a los 15 dias, 3 y 6 meses respectivamente. A las muestras que resultaron positivos se les amplió el rango de dilución para determinar título. Al realizar la comparación entre ambas muestras, sangre en papel de filtro y suero, encontramos que no existían diferencias de detección significativas, tanto para los casos positivos como los negativos. No obstante se observó en ambas muestras y de forma general una disminución del titulo de anticuerpos (una dilución) al transcurrir el tiempo máximo establecido en nuestro estudio (6 meses).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Serum sample obtained from a male, 12 year old patient suffering from Guillain-Barré syndrome (GBS) was positive for human T-lymphotropic virus (HTLV-I) antibody by the enzyme-linked immunosorbent assay (ELISA) and the Western Blot analysis (WB). Attempts to isolate enteroviruses (including poliovirus) from faecal material in both tissue culture and suckling mice were unsuccessful; in addition, acute and convalescent paired serum samples did not show any evidence of recent poliovirus infection when tested against the three serotypes. Specific tests for detection of Epstein-Barr virus infection were not performed; however, the Paul-Bunnel test yielded negative results. ELISA for detection of anti-cytomegalovirus IgM was also negative. The concomitant occurrence of either adult T cell leukemia (ATL) or lymphoma was not recorded in this case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic performance indexes of sensitivity, specificity, positive predictive value and efficiency were determined for dot-ELISA and IgG-ELISA tests in 340 leishmaniasis sera. Sensitivity of the dot-ELISA was significantly lower than IgG-ELISA's; the two tests had indexes of specificity and positive predictive value of the same magnitude. Seventy-eight sera gave a negative dot-ELISA test result and a positive IgG-ELISA test result. When sera were classified according to different criteria as how to interpret this diversity, the kappa statistic did not corroborate the classification indicating that the two tests display a substantial strength of agreement. The results presented indicate that performance indexes accrued in a survey where variables arc well known may be extrapolated to other population studies if the disease presents itself as highly prevalent (due to a selection bias or not) and may be expected to discriminate a disease status among test positives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analisou-se o teste de imunofluorescência indireta com microfilárias de W. bancrofti tratadas pela papaína, como antígeno, amplamente utilizado em Recife para o imunodiagnóstico da filariose linfática. Foram testados soros de 50 pacientes portadores das diversas formas clínicas da doença, incluindo microfilaremia assintomática, eosinofilia pulmonar tropical, elefantíase de membros inferiores, linfagite aguda e quilúria. Para o grupo controle, foram selecionados 50 indivíduos vivendo pelo menos há 5 anos em área endêmica, sem nenhuma evidencia clínica e/ou laboratorial da doença, constituindo os chamados endêmicos normais. A sensibilidade e especificidade do teste, segundo diferentes pontos de corte, mostraram a impossibilidade de diferenciação entre o grupo controle e o grupo sabidamente infectado. Também não foi possível estabelecer correlação entre os títulos encontrados e as diferentes formas clínicas. Foi considerada a existência de reações cruzadas relacionadas a helmintíases intestinais, porém nenhuma relação direta foi encontrada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La disponibilidad del sistema Ultramicroanalítico (SUMA) y de un antígeno especie-específico del M. leprae obtenido mediante síntesis química, permitió la normalización y validación de un ultramicroELISA para la detección de anticuerpos IgM específicos a esta micobacteria. El análisis de 433 sueros de banco de sangre y 265 sueros usados para validar el método y clasificados en un grupo control de donantes de banco de sangre (100), un grupo de pacientes tuberculosos (50), un grupo de enfermos de lepra (65) y un grupo de contactos de estos enfermos (50), mostró la especificidad del ensayo para evidenciar la infección con el M. leprae. Los resultados obtenidos del estudio adicional de 140 muestras de suero de contactos de enfermos estuvieron estrechamente correlacionados (r = 0,98) con los resultados obtenidos por la técnica de microELISA convencional. La utilización del SUMA no solo permite un notable ahorro de reactivos si no además facilita la lectura, cálculo, validación y almacenamiento automático de los resultados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dot-enzyme-linked immunosorbent assay (dot-ELISA) was standardized using somatic (S) and excretory-secretory (ES) antigens of Toxocara-canis for the detection of specific antibodies in 22 serum samples from children aged 1 to 15 years, with clinical signs of toxocariasis. Fourteen serum samples from apparently normal individuals and 28 sera from patients with other pathologies were used as controls. All samples were used before and after absorption with Ascaris suum extract. When the results were evaluated in comparison with ELISA, the two tests were found to have similar sensitivity, but dot-ELISA was found to be more specific in the presence of the two antigens studied. Dot-ELISA proved to be effective for the diagnosis of human toxocariasis, presenting advantages in terms of yield, stability, time and ease of execution and low cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uma epidemia de dengue tipo 1 se iniciou em Novembro de 1990 na Região de Ribeirão Preto, Norte do Estado de São Paulo. Foram confirmados por exames laboratoriais cerca de 3.500 casos até fevereiro de 1991. A Unidade de Pesquisa em Virologia da Faculdade de Medicina de Ribeirão Preto - USP, estudou soros de 502 pessoas suspeitas de apresentarem dengue. Fez-se o diagnóstico sorológico através do método da inibição da hemaglutinação (HAI) para dengue tipo 1 em 19% dos analisados. Passou-se a utlilizar um teste imuno-enzimático para dengue em culturas celulares infectadas (EIA-ICC), que permite identificação simultânea de IgG e IgM. O EIA-ICC embora menos sensível quando comparado ao HAI (89%), mostrou-se mais eficiente, porque: dispensou a obtenção de segundas amostras séricas para o diagnóstico; trata-se de técnica simples, podendo ser efetuada em apenas 5 horas. O vírus dengue tipo 1 foi isolado do sangue de 21 pacientes, por inoculação em células de mosquitos C6/36. Fez-se a identificação dos vírus isolados por método de imunofluorescência indireta, utilizando anti-soro contra todos os flavivirus e anticorpos monoclonais tipo-específicos de dengue. Os sintomas mais freqüentemente observados em 71 indivíduos com diagnóstico de dengue confirmado foram febre (90% dos casos), mialgias (57%) e artralgias (41%)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En una zona endémica de la República Argentina se llevó a cabo un ensayo de campo de la prueba inmunoenzimática ELISA para la detección de antígenos (cAg) y complejos inmunes circulantes (CIC) en sueros de pacientes chagásicos crónicos. Del total de 215 muestras de sangre analizadas, 51 fueron positivas para ELISA-CIC y 45 lo fueron para ELISA-cAg. De los 74 (34,32% de la población) sujetos considerados infectados con dos reacciones serológicas positivas, 49 (66,21%) presentaron CIC en suero, en tanto que en 43 (58,11%) de ellos se encontró cAg por ELISA. Solo en 2 casos serológicamente no reactivos, se detectaron inespecíficamente CIC y cAg. Dentro del grupo considerado no infectado, se observó reactividad inespecífica de bajo título por una de las pruebas serológicas en 16 (11,35%) de 141 individuos. Estos sueros arrojaron resultados consistentemente negativos por ELISA-CIC y cAg demostrando la utilidad de estos métodos de diagnóstico antigénico en casos de serología conflictiva. La determinación de fracciones antigénicas circulantes por ELISA en individuos chagásicos crónicos permite evidenciar la infección por T. cruzi de manera más directa que midiendo la respuesta inmune humoral en el huésped, presentando además mayor sensibilidad que el diagnóstico parasitológico clásico

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram estudados 50 pacientes com epilepsia em três Serviços de Neurologia do Município de Londrina, Paraná. A prevalência da positividade da reação imunoenzimática (ELISA) para cisticercose no líquido cefalorraquidiano (LCR) e no soro desses pacientes foi de 34,0% e 20,0%, respectivamente. Houve diferença estatisticamente significativa quando essas duas taxas foram comparadas com a positividade da reação, no LCR e no soro, no grupo controle, constituído por pessoas que não apresentavam doença neurológica. Não houve associação entre o tipo de convulsão (generalizada ou parcial) e o índice de positividade da reação imunoenzimática (ELISA) para cisticercose no LCR. Encontrou-se número maior de pacientes com ELISA reagente para cisticercose em moradores da zona rural em relação aos moradores da zona urbana do município.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Registramos a ocorrência de epidemia de dengue causada pelo sorotipo 2 (DEN 2) na cidade de Araguaina, estado do Tocantins (TO) situado no Brasil central. Quatrocentos indíviduos de 74 famílias, residentes nos bairros S. João, Araguaina Sul e Neblina foram entrevistados e sangrados, independentemente de terem adoecido ou não. Os soros tanto de adultos quanto de crianças de ambos os sexos foram usados para pesquisa de anticorpos inibidores da hemaglutinação (IH) e IgM através de ensaio imunoenzimático (MAC ELISA). Nas casas onde haviam doentes no momento do inquérito, sangue total também foi colhido para tentativa de isolamento de vírus. O quadro clínico apresentado pelos pacientes foi caracterizado por febre, cefaléia, mialgias, artralgias e exantema do tipo máculo-papular não pruriginoso. A infecção foi mais frequente em mulheres (33.9%) do que nos homens (23.8%), ocorrendo em todas as faixas etárias, inclusive em crianças com menos de um ano de idade, bem como em maiores de 70 anos. Um total de 1105 mosquitos (56 fêmeas e 45 machos de Culex quinquefasciatus e 567 fêmeas e 437 machos de Aedes aegypti) foram obtidos a partir de larvas coletadas em Araguaina. As fêmeas de Ae. aegypti obtidas das larvas fizeram repasto sangüíneo em 8 pacientes febris. O diagnóstico laboratorial foi feito por isolamento de vírus (cultura de células de Aedes albopictus, clone C6/36) e por sorologia (IH e MAC ELISA). Foram isoladas 5 amostras de DEN 2 de pacientes febris e tipadas por imunofluorescência indireta usando anticorpos monoclonais de dengue. Nenhuma amostra viral foi isolada de mosquitos. Outrossim, comprovou-se infecção em 111 pessoas sangradas, o que revelou um índice de positividade de 27.75% (111 em 400), sendo que 66.2% das famílias estudadas apresentaram pelo menos um indivíduo positivo. Ocorreram ainda, 26.1% de infecções assintomáti-cas. Por outro lado, a correlação de positividade entre os dois testes usados (IH e MAC ELISA) foi de 94.6%. Estimamos que ocorreram aproximadamente 83.250 casos da doença, entre 15 de março a 31 de maio de 1991. Esta é a primeira epidemia de DEN 2 em um estado da Amazônia Brasileira, portanto em área endêmica de febre amarela, e a primeira evidência da interiorização do DEN 2, até então restrito ao Rio de Janeiro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se realizó un estudio prospectivo en 40 trabajadores de una granja avícola (grupo 1) considerados con riesgo de exposición a Histoplasma capsulatum, agente etiológico de la histoplasmosis, y en 16 individuos sin riesgo profesional de exposición a dicho agente (grupo 2). En ambos grupos se aplicó la prueba intradérmica de histoplasmina y se obtuvo el suero antes de su aplicación y a los 30 y 180 días después de realizada dicha prueba. Se determinó el nivel de anticuerpos anti-H. capsulatum mediante las técnicas de ELISA e inmunodifusión doble. En los dos grupos de población estudiados la aplicación intradérmica de histoplasmina, aún en los casos en que la respuesta fue positiva, no constituyó un estímulo antigénico suficiente para provocar un aumento en los niveles de anticuerpos anti-H. capsulation detectables por las técnicas serológicas empleadas. Los resultados obtenidos contribuyen a la mejor interpretación de la prueba de ELISA en el diagnóstico de la histoplasmosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En este trabajo se establecen las condiciones optimas para la detección de anticuerpos IgM al glicolipido fenólico-I (GF-I) en muestras de sangre en papel de filtro utilizando el UltramicroELISA HANSEN y la tecnologia SUMA. Se estudiaron 300 donantes de sangre y 58 pacientes leprosos. Para estas dos poblaciones se compararon los resultados de muestras de sangre seca colectadas en papel de filtro SS-2992 con los de suero, y se obtuvo una correlación de 0.919 para donantes de sangre, 0.969 para pacientes y 0.954 para el total de las dos poblaciones. Se obtuvo una coincidencia de 98% en pacientes y 96% en donantes. En la población de pacientes la sensibilidad fue de 93% y la especificidad de 100% para las muestras de sangre seca evaluadas por el UMELISA HANSEN, con respecto a las muestras de suero analizadas por esta misma tecnica.