207 resultados para LIQUID CHROMATOGRAPHY
Resumo:
A simple, RP-HPLC method was established for determining moxifloxacin and ketorolac in pharmaceutical formulations. Moxifloxacin, ketorolac and their degradation products were separated using C8 column with methanol and phosphate buffer pH 3.0 (55:45 v/v) as the mobile phase. Detection was performed at 243 nm using a diode array detector. The method was validated using ICH guidelines and was linear in the range 20-140 µg mL-1 for both analytes. Good separation of both the analytes and their degradation products was achieved using this method. The developed method can be applied successfully for the determination of moxifloxacin and ketorolac.
Resumo:
The present work consists of the development and validation of analytical method for evaluation of glycyrrhizic acid, salicylic acid, and caffeine in chitosan-alginate nanoparticles by high performance liquid chromatography. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The methods were applied to nanoparticles suspensions containing the drugs and were able to determine the entrapment efficiency successfully. The best entrapment efficiency was achieved with the glycyrrhizic acid (95.4%).
Resumo:
Tebuthiuron (TBH) is a herbicide widely used in different cultures and known for its toxic effects. Electrochemical methods are promising for removing pollutants such as pesticides. This study showed the degradation of TBH using a DSA® anode operated at current densities of 50 to 200 mA cm-2. Removal presented pseudo-first order kinetics while high-pressure liquid chromatography (UV detection) showed two peaks, ascribed to degradation intermediates. The maximum percentage of total organic carbon removed was 12.9%. Ion chromatography revealed that higher concentrations of nitrate and nitrite ions formed with increasing current density.
Resumo:
Simaba guianensis subesp. ecaudata (Simaroubaceae) is a tree found in the Brazilian Amazon. This work describes for the first time the fractionation of stems of this species that resulted in the isolation of the cytotoxic triterpene piscidinol A, the alkaloid 9-methoxycanthin-6-one, caryophyllene oxide, also isolated for the first time from this species and a new alkaloid (6-methoxy-(9H-β-carbolin-1-il)-(Z)-2-propenoic acid). Quantification of 9-methoxycanthin-6-one in different extracts and fractions of stems of S. guianensis by high performance liquid chromatography was also performed. The concentration of 9-methoxycanthin-6-one in methanolic and aqueous extracts were inferior to the known cytotoxic concentration of this compound.
Resumo:
Determination of organic acids in soils and organic materials is important due to the important role they play in improving the soil's physical, chemical and microbiological conditions. This study identified and quantified low molecular weight organic acids (LMWOA) in soils (dystroferric Red Latosol, dystrophic Red-Yellow Latosol and Quartzarenic Neosol) and organic materials (cow, pig, chicken, quail and horse manures, sawdust, coconut fiber, pine bark, coffee husks, biochar, organic substrate, sewage sludges 1 and 2, garbage compost, pig slurry compost). The following acids were identified: acetic, citric, D-malic, formic, fumaric, maleic, malonic, oxalic, quinic, shikimic, succinic and tartaric.
Resumo:
This is an overview of LC-MS techniques applied for macrolide determination in food, including sample preparation and method validation, as well as the policies adopted by international agencies regarding their presence in food. Techniques for the analysis of macrolides in food normally include solid phase or liquid-liquid extraction followed by HPLC. UHPLC presents advantages in running time, detectability and solvent consumption. Triple-quadrupoles are the most common analyzers in instruments used for the determination of contaminants in food, but time-of-flight and ion-trap spectrometers have been successfully applied for analyses focusing on the investigation of structural formula or the presence of degradation products.
Resumo:
This paper reports the development and validation of a new analytical method using UV spectrophotometry to quantify carvedilol (CRV) in hydrophilic matrices and raw material. This method was shown to be linear, accurate, precise, robust and to have adequate limits of quantification and detection (LQ and LD, respectively), allowing its use in the dissolution test of hydrophilic matrices. The content of CRV determined through this method was compared with two previously validated methods based on the reference techniques of High Performance Liquid Chromatography (HPLC) and Potentiometric Titrations (PT). ANOVA confirmed the equivalence of these methods, showing no significant differences.
Resumo:
An investigation was conducted into the production of xylose by acid hydrolysis of rice husks and its subsequent bioconversion to xylitol. The parameters were optimised using the response surface methodology. The fermentation stage took place with the aid of the yeast species Candida guilliermondii and Candida tropicalis. An evaluation of the influence of several biomass pre-treatments was also performed. The effects of the acid concentration and hydrolysate pH on xylitol global yield were also assessed, and the highest yield of xylitol was 64.0% (w/w). The main products, xylose and xylitol, were identified and quantified by means of liquid chromatography.
Resumo:
A fast analytical method for determination of hydroquinone in pharmaceutical formulations employing batch injection analysis (BIA) with amperometric detection using a boron-doped diamond electrode is described. The supporting electrolyte was a 0.1 mol L-1 H2SO4 solution (the single reagent used for analysis). The method showed good repeatability (RSD of 0.45%, n=20), wide linear range (from 10 to 2000 µmol L-1, R=0.9999), low detection limit (0.016 µmol L-1) and satisfactory recovery values (91-96%). Accuracy of the method was evaluated by comparative analyses using high-performance liquid-chromatography. The ability to replace the electronic pipette by disposable syringes (injection procedure) in BIA systems was also shown.
Resumo:
Tobacco cultivation in shallow soils and steep landscape under intense use of agrochemicals contributes to environment degradation. In this study, we assessed the concentration of agrochemicals in draw wells used for human consumption and a creek in a small catchment predominantly cropped to tobacco. Chlorpyrifos, flumetralin, and iprodione were determined by gas chromatography with electron capture detection, while imidalcloprid, atrazine, simazine, and clomazone were quantified by high-performance liquid chromatography with UV detection. Considering all sampling sites, all agrochemicals were detected at least once, except for flumetralin. The occurrence of agrochemicals in tobacco crops is a consequence of their fast transfer to surface water.
Resumo:
This work describes three C8-stationary phases for high performance liquid chromatography based on silica metallized with ZrO2, TiO2 or Al2O3 layers, having poly(methyloctylsiloxane) immobilized onto their surfaces. The stationary phases were characterized using XRF, XAS, FTIR, SEM and elemental analysis to determine the physical characteristics of the oxide and polysiloxane layers formed on the surfaces and chromatographically to evaluate the separation parameters. The results show the changes on the silica surface and allowed proposing a structure for the oxide layer, being observed tetrahedral and octahedral structures, what is completely new in the literature. The formation of a homogeneous layer of metallic oxide (TiO2 and ZrO2) was observed on the silica. The C8-titanized and C8-aluminized stationary phases presented good chromatographic performances, with good values of asymmetry and efficiency. All stationary phase presented few loss of the polymeric layer after the HPLC, indicating that this layer is well attached on the metalized support.
Resumo:
Blooms of cyanobacteria represent a public health risk due to their cyanotoxins such as microcystins. Liquid chromatography techniques to separate and quantify microcystins invariably use acetonitrile as the organic component of the mobile phase. The price and availability of acetonitrile together with its elevated toxicity encourage the validation of acetonitrile-free methods of microcystin analysis. In this work, methanol was employed as the organic solvent of the mobile phase and the validation method was performed with different environmental water samples. The method showed limits of detection between 0.17 and 0.25 µg/L and of quantification between 0.55 and 0.82 µg/L for the microcystin variants: -RR, -YR, -LR, -LA.
Resumo:
A method was developed for the analysis of 31 pharmaceutical compounds in Lisbon's drinking water system, using solid-phase extraction (SPE) and ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS). The method was validated through estimation of the linearity range, method detection and quantification limits, matrix effects, precision and accuracy. The method detection and quantification limit ranges were 0.009-10 and 0.03-33 ng/L, respectively. Analytes were quantified in water samples collected from the EPAL (Empresa Portuguesa das Águas Livres S.A.) supply system. Carbamazepine, atenolol, sulfadiazine, sulfamethazine, sulfapyridine, sulfamethoxazole, acetaminophen, caffeine and erythromycin were quantified in the analysed samples.
Resumo:
Phenylpropanoid glycoside verbascoside was isolated and identified from the ethyl acetate fraction of the aerial parts of Buddleja stachyoides Cham. & Schltdl. by 1H-NMR. A method using high-performance liquid chromatography has been developed and validated for determination of verbascoside in alcoholic crude extract of the aerial parts of B. stachyoides. Analysis was performed on a Phenomenex® Gemini-NX C18 analytical column (250 mm × 4.6 mm; 5 µm) using a mobile phase (pump A - aqueous solution containing H2SO4 (0.01 M), H3PO4 (0.4%), and (C2H5)2NH (0.4%); pump B - methanol:aqueous (95:5) solution containing H2SO4 (0.05 M), H3PO4 (2%), and (C2H5)2NH (0.2%); pump C - acetonitrile:aqueous (90:10) solution containing H2SO4 (0.05 M) and H3PO4 (2%)) and a diode array detector at 325 nm. The method was validated in accordance with ANVISA guidelines and may be applied to quality control of herbal medicine with aerial parts of B. stachyoides.
Resumo:
A simple procedure based on stir bar sorptive extraction and high-performance liquid chromatography-ultraviolet/photodiode array detection (SBSE/LC-UV/PAD) to determine intermediates and by-products of esfenvalerate is described. The influence of organic modifier, ionic strength, extraction time, temperature and pH were simultaneously evaluated by using a factorial experimental design. The utilization of different organic solvents and desorption times were also investigated to establish the optimal conditions for SBSE liquid desorption. Among the ten different peaks (intermediates and by-products) detected after degradation of esfenvalerate, eight (including 3-phenoxybenzoic acid and 3-phenoxybenzaldehyde) were successfully extracted by SBSE under the optimized conditions.