301 resultados para total solids


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A partir da observação de três pacientes com aganglionose total do cólon e de revisão da literatura, os autores salientam as particularidades diagnósticas desta entidade que justificam uma análise separada da forma típica da doença de Hirschsprung. Não há sinais radiológicos patognomônicos e o diagnóstico definitivo somente pode ser obtido pelo estudo histopatológico. Considerando sua alta incidência de complicações e mortalidade, a aganglionose total do cólon deve ser considerada em todo recém-nascido ou criança maior com evidências radiológicas de obstrução intestinal, quaisquer que sejam os achados de enema opaco.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractObjective:To define the distal femur rotation pattern in a Brazilian population, correlating such pattern with the one suggested by the arthroplasty instruments, and analyzing the variability of each anatomic parameter.Materials and Methods:A series of 101 magnetic resonance imaging studies were evaluated in the period between April and June 2012. The epidemiological data collection was performed with the aid of the institution's computed imaging system, and the sample included 52 male and 49 female patients. The measurements were made in the axial plane, with subsequent correlation and triangulation with the other plans. The posterior condylar line was used as a reference for angle measurements. Subsequently, the anatomical and surgical transepicondylar axes and the anteroposterior trochlear line were specified. The angles between the reference line and the studied lines were calculated with the aid of the institution's software.Results:The mean angle between the anatomical transepicondylar axis and the posterior condylar line was found to be 6.89°, ranging from 0.25° to 12°. For the surgical transepicondylar axis, the mean value was 2.89°, ranging from –2.23° (internal rotation) to 7.86°, and for the axis perpendicular to the anteroposterior trochlear line, the mean value was 4.77°, ranging from –2.09° to 12.2°.Conclusion:The anatomical transepicondylar angle showed mean values corresponding to the measurement observed in the Caucasian population. The utilized instruments are appropriate, but no anatomical parameter proved to be steady enough to be used in isolation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a tropical coastal area. During 6 months the composition of rain samples collected simultaneously over 24h with an open collector and with an automatic opened collector (KFA - J¸lich Type) at 500m of the Atlantic coastline of Salvador were compared. All average concentrations were higher for the "total" samples than for the "wet only" samples, except for hydrogen ions, nitrate and ammonium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multivariate curve resolution method, "GENERALIZED RANK ANNIHILATION METHOD (GRAM)", is discussed and tested with simulated and experimental data. The analysis of simulated data provides general guidelines concerning the condition for uniqueness of a solution for a given problem. The second-order emission-excitation spectra of human and animal dental calculus deposits were used as an experimental data to estimate the performance of the above method. Three porphyrinic spectral profiles, for both human and cat, were obtained by the use of GRAM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents an automated system for potentiometric determination of free and total cyanide which employs a homogeneous membrane tubular ion-selective electrode. After the electrode is assembled, it is connected to a system composed of 3 three-way solenoid valves, sample line, carrier line, acid stream, and gas diffusion chamber. A Turbo Pascal® computer program, developed specifically for this task, automatically performs all the steps involved in data acquisition and processing. The proposed analytical procedure offers operational simplicity, since detection is performed by a tubular electrode, whose assembly is fast and easy. The system has shown reproducibility (r.s.d. < 0.5%, n=6) and high speed (30 readings/hour); it is efficient for determination of free and total cyanide in waste waters of starch processing plants. The detection limit was 1.2x10-5 and 1.5x10-5 mol L-1, for determination of free and total cyanide, respectively. The linear response range was between 1.2x10-5 and 1.0x10-2 mol L-1 for free cyanide and between 1.5x10-5 and 1.0x10-2 for total cyanide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and simple system was proposed for the in situ measurement of total aldehyde in outdoor or indoor ambient. The method is based on the use of a reagent drop as an useful interface to preconcentrate the sample prior to determination of total aldehyde as formaldehyde. The drop is formed at the tip of a cylindrical tube that contains two optical fibers placed on opposite sides and in contact with the reagent solution. One optical fiber carries the red light to the drop form a light emitting diode (LED). The transmitted light is measured by a second optical fiber/photodiode system. The analytical signal is read and converted into absorbance. The reagent solution of 3-methyl-2-benzothiazoline hydrazone (MBTH) forms a blue cation during reaction with formaldehyde that can be measured at 660 nm. Some aspects of kinetics reaction formation of dye were reevaluated. The formaldehyde reacts with MBTH and forms the azine in about 12 min. The oxidation of MBTH by Fe (III) and the formation of dye requires 3 min. The absorbance of the reagent drop is proportional to the sampling time and to the analyte concentration. The absorbance signal increases with increased sample gas flow until a maximum is reached then decreases until it forms a plateau. The proposed method was evaluated using both outdoor and indoor samples, and it was shown to viable provide an accurate measure of total aldehyde.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A review about composition, origin and importance of carbohydrates in honey is presented. Fructose and glucose are the major carbohydrates, ranging from 65-85 % of the total soluble solids. Other minor carbohydrates, chiefly di- and trisaccharides, have been also identified. Fructose, glucose and sucrose are mainly originated from nectar. Oligosaccharides are mainly formed by trans-alpha-D-glucosylation reactions catalysed by honeybee alpha-D-glucosidase. The profile of carbohydrates can be useful for the identification of the brazilian region in which honey was produced and may also be useful for testing brazilian honey authenticity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The monitoring of the pollution status of the Brazilian coast is hampered by the lack of a consistent environmental indicator. We propose Hg as an environmental proxy to anthropogenic pollution of coastal regions due to its absence in the Brazilian geology, its ubiquity in anthropogenic effluents, and its toxicity. Available data suggest Hg "backgrounds" in coastal sediments of 1-10 ng g-1, in the East and 15-30 ng g-1 in the South. We suggest short sediment cores to establish these values estimating a geo-accumulation index to compare all areas. The distribution of index values showed the majority of southern coast at least moderately contaminated whereas many eastern areas are still pristine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermospray flame furnace Atomic Absorption Spectrometry (TS-FF-AAS) was used for the total determination of Cd, Pb and Zn in fresh water and seawater samples at µg L-1 levels, and in marine sediment samples at µg g-1 levels. Using a sample loop of 50 µL and a peristaltic pump the samples were transported into the metallic tube placed over an air/acetylene flame, through a ceramic capillary (o.d. = 3.2 mm) containing two parallel internal orifices (i.d = 0.5 mm). The detection limits determined for Cd, Pb and Zn using a synthetic water matrix (2.5% m/v NaCl, 0.5% m/v MgCl2 and 0.8% m/v CaCl2) were 0.32 µg L-1; 2.6 µg L-1 and 0.21 µg L-1 respectively. The methodology by TS-FF-AAS was validated by determination of Cd, Pb and Zn in certified reference materials of water and marine sediment, and the t-test for differences between means was applied. No statistically significant differences were established in fresh water and seawater (p>0.05), whereas differences became apparent in marine sediment (p<0.03).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this paper is to investigate the physical and chemical quality of the water of the Descoberto River during the dry and rainy seasons by measuring pH, temperature, electric conductivity, total dissolved solids, turbidity, color, alkalinity and NO3-, SO4(2-), PO4(3-), NH4+, Cl- and HCO3-, and the elements Sr, Mo, Cd, Y, Ti, Ca, V, Mg, Fe, Si, Ni, Zr, Cu, Al, Cr, Mn, Ba, Co, Zn, P, Na and K. The results showed high concentrations in both seasons, with dilution along the course of the river, minimizing for a while problems that compromise the quality of the water of this source. However, a progressive deterioration can occur due to an increase in the discharge of pollutants, resulting from population growth, agricultural activities and other factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several extraction procedures are described for the determination of exchangeable and fixed ammonium, nitrate + nitrite, total exchangeable nitrogen and total nitrogen in certified reference soils and petroleum reservoir rock samples by steam distillation and indophenol method. After improvement of the original distillation system, an increase in worker safety, a reduction in time consumption, a decrease of 73% in blank value and an analysis without ammonia loss, which could possibly occur, were achieved. The precision (RSD < 8%, n = 3) and the detection limit (9 mg kg-1 NH4+-N) are better than those of published procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a fast method for the determination of the total sugar levels in samples of raw coffee was developed using the near infrared spectroscopy technique and multivariate regression. The sugar levels were initially obtained using gravimety as the reference method. Later on, the regression models were built from the near infrared spectra of the coffee samples. The original spectra were pre-treated according to the Kubelka-Munk transformation and multiplicative signal correction. The proposed analytical method made possible the direct determination of the total sugar levels in the samples with an error lower by 8% with respect to the conventional methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total Hg content in soils of Baixada Santista, affected by different sources of pollution, and Cardoso Island, which is almost free of anthropogenic activities, were determined by CVAAS. To explain the fate of Hg in the ecosystem, pH, Eh, AVS, Stotal and Total Organic Carbon were also obtained throughout the soil profiles. With the exception of two sampling sites the average content of Hg in samples obtained for Baixada Santista was 0.34 ± 0.20 mg kg-1, which was close to the average data at Cardoso Island (0.30 ± 0.21 mg kg-1). Both of them were below the limit established by CETESB - 0.50 mg kg-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work investigated the effect of coprecipitation-oxidant synthesis on the specific surface area of perovskite-type oxides LaBO3 (B= Mn, Ni, Fe) for total oxidation of ethanol. The perovskite-type oxides were characterized by X-ray diffraction, nitrogen adsorption (BET method), thermogravimetric analysis (TGA-DTA), TPR and X-ray photoelectron spectroscopy (XPS). Through method involving the coprecipitation-oxidant was possible to obtain catalysts with different BET specific surface areas, of 33-51 m²/g. The results of the catalytic test confirmed that all oxides investigated in this work have specific catalytic activity for total oxidation of ethanol, though the temperatures for total conversion change for each transition metal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffuse reflectance near-infrared (DR-NIR) spectroscopy associated with partial least squares (PLS) multivariate calibration is proposed for a direct, non-destructive, determination of total nitrogen in wheat leaves. The procedure was developed for an Analytical Instrumental Analysis course, carried out at the Institute of Chemistry of the State University of Campinas. The DR-NIR results are in good agreement with those obtained by the Kjeldhal standard procedure, with a relative error of less than ± 3% and the method may be used for teaching purposes as well as for routine analysis.