254 resultados para semi-aqueous capillary electrophoresis
Resumo:
This paper describes the development of a methodology for solid phase extraction (SPE) and pre-concentration of nitrosamines from aqueous samples using granular activated charcoal as stationary phase. micelar electrokinetic capillary Chromatography (MEKC) was used for the separation and identification of the nitrosamines in the extracts. Using a sample with 50 µg l-1 of each nitrosamines standards (dimethylnitrosamine, DMN; diethylnitrosamine, DEN; N-nitrosopyrrolidine, NPYR; N-nitrosopiperidine, NPIP; N-nitrosomorpholine, NMOR), the methodology showed a range of recuperation from 29 to 107% with a linear zone between 10 and 500 µg l-1. The developed methodology can be applicable to the determination of these analytes in different aqueous samples.
Resumo:
The total synthesis of sulfadiazine and silver sulfadiazine from readily available starting materials was adapted to semi-micro laboratory scale and is proposed as an experiment in drug synthesis for undergraduate courses.
Resumo:
Fumonisins are mycotoxins occurring worldwide, mainly in maize and maize-based food products, which could affect animal and human health. This paper reviews analytical methodologies for the determination of these fungal toxins in foods. It includes extraction, cleanup, derivatization procedures, detection, quantification, and confirmation procedures. Initial attempts at gas chromatographic methods and thin layer chromatography were supplanted by liquid chromatographic methods, mainly performed with fluorometric detection, or mass spectrometry detection, enabling the analysis of polar and thermolabile chemicals without chemical derivatization, which results in lower limits of detection. Alternative methods, such as enzyme linked immunosorbent assay or zone capillary zone electrophoresis, are also described.
Resumo:
This paper focuses: (i) the development of a measurement technique for the determination of atmospheric C2-C6 hydrocarbons with sampling in canisters and analysis by gas chromatography/flame ionisation detector (GC/FID), (ii) the improvement of an existent adsorption-sampling technique with Tenax TA tubes for the determination of C6-C11 hydrocarbons and analysis by GC/FID after thermal desorption and cryogenic concentration, (iii) the identification of compounds present in ambient air by gas chromatography/mass spectrometry (GC/MS) for both canister and Tenax samples, (iv) a program of interlaboratorial comparison for quality control of C2-C11 analyses, and (v) the seasonal characterisation of ambient air C2-C11 hydrocarbons.
Resumo:
The supply of drinking water in the Metropolitan Area of São Paulo City has been a great and serious challenge in the latest years. This work demonstrates the viability of the evaluation of the degree of contamination of the water reservoirs using analytical procedures, which allow the analysis of several compounds at relatively low cost: stripping square wave voltammetry (SSWV) and capillary zone electrophoresis with contactless conductivity detection (CZE-CCD). The results of ionic composition indicated significant contamination of the Guarapiranga water system by human activities on the reservoir banks. In fact, the Guavirutuba and Itupu streams presented high concentrations of phosphate and ammonium ions. This can be directly related to misuse and unruled occupation of the soil and precarious sanitary infrastructure.
Resumo:
Thermosensitive hydrogels were synthesized using alginate-Ca2+ in association with a thermosensitive polymer, such as PNIPAAm. The mechanical properties of the hydrogels were determined measuring the maximum tension of deformation. With the increase of the temperature by 25 to 40 ºC above the LCST the chains of PNIPAAm collapsed, dragging the alginate net and diminishing the size of the pores. The decrease in the size of the pores of the hydrogel was followed by an increase in the mechanicals resistance of the material.
Resumo:
The presence of illicit drugs such as cocaine and marijuana in US paper currency is very well demonstrated. However, there is no published study describing the presence of cocaine and/or other illicit drugs in Brazilian paper currency. In this study, Brazilian banknotes were collected from nine cities, extracted and analyzed by capillary gas chromatography/mass spectrometry, in order to investigate the presence of cocaine. Bills were extracted with deionized water followed by ethyl acetate. Results showed that 93% of the bills presented cocaine in a concentration range of 2.38-275.10 µg/bill.
Resumo:
The present work analyzed the effect of the temperature and type of salt on the phase equilibrium of aqueous two-phase systems (ATPS) formed by poly (ethylene glycol) (PEG) 1500 + potassium phosphate, from (278.15 to 318.15) K, and PEG 1500 + sodium citrate, from (278.15 to 298.15) K. The rise of the temperature normally increased the slope of the tie line (STL). With respect to the influence of the type of salt, sodium citrate showed better capability to induce phase separation, when compared to potassium phosphate.
Resumo:
Being mercury one of the most toxic heavy metals present in the environment, it is of major concern to develop cleanup technologies to remove it from wastewater and recover mercury polluted ecosystems. In this context, we study the potential of some microporous titanosilicates and zirconosilicates for taking up Hg2+ from aqueous solutions. These materials have unique chemical and physical properties, and here we are able to confirm that they readily remove Hg2+ from aqueous solutions. Moreover, the presence of the competitive Mg2+ and Na+, which are some of the dominant cations in natural waters, does not reduce the uptake capacity of some of these materials. Thus, several inorganic materials reported here may have important environmental applications, efficiently removing Hg2+ from aqueous solutions.
Resumo:
In this work, we provide an investigation of the role and strength of affinity interactions on the partitioning of the glucose-6-phosphate dehydrogenase in aqueous two-phase micellar systems. These systems are constituted of micellar surfactant solutions and offer both hydrophobic and hydrophilic environments, providing selectivity to biomolecules. We studied G6PD partitioning in systems composed of the nonionic surfactants, separately, in the presence and absence of affinity ligands. We observed that G6PD partitions to the micelle-poor phase, owing to the strength of excluded-volume interactions in these systems that drive the protein to the micelle-poor phase, where there is more free volume available.
Resumo:
The spatial and temporal retention of metals has been studied in water and sediments of the Gavião River, Anagé and Tremedal Reservoirs, located in the semi-arid region, Bahia - Brazil, in order to identify trends in the fluxes of metals from the sediments to the water column. The determination of metals was made by ICP OES and ET AAS. The application of statistical methods showed that this aquatic system presents suitable conditions to move Cd2+ and Pb2+ from the water column to the sediment.
Resumo:
This work investigates the adsorption of Alizarin, Eriochrome Blue Black R and Fluorescein using chitosan, goethite and magnetite as adsorbents. For Alizarin, the best adsorbent is chitosan with a Langmuir parameter of 15.8 mmol dye/g adsorbent. For Eriochrome Blue Black R only 1.94 mmol dye/g chitosan is adsorbed. Langmuir parameters for the Alizarin adsorption on both iron oxides display one or two orders of magnitude lower than for chitosan and two orders of magnitude lower in the case of Eriochrome Blue Black R. Fluorescein does not adsorb in appreciable amounts on chitosan and it presents the lower affinity on the iron oxides.
Resumo:
This study examined the spatial and temporal variations of six important parameters of the salt accumulation process in water samples collected along section urban of Contas River. The Na+, K+, Ca2+ and Mg2+ concentrations were determined by FAAS. The conductivity, total dissolved solids, Na+ and Ca2+ presented the largest seasonal and spatial variations in the urban area demonstrated that are appropriate indicators of urban contamination. The readily soluble salts in drainage urban, contribute for the degradation of the water of rivers located in semi-arid zones.
Resumo:
The present study deals with phenol adsorption on chitin and chitosan and removal of contaminants from wastewater of a petroleum refinery. The adsorption kinetic data were best fitted to first- and second-order models for chitosan and chitin, respectively. The results of adsorption isotherms showed Langmuir model more appropriately described than a Freundlich model for both adsorbents. The adsorption capacity was 1.96 and 1.26 mg/g for chitin and chitosan, respectively. Maximum removal of phenol was about 70-80% (flow rate: 1.5 mL/min, bed height: 18.5 cm, and 30 mg/L of phenol. Wastewater treatment with chitin in a fixed-bed system showed reductions of about 52 and 92% for COD and oil and greases, and for chitosan 65 and 67%, respectively. The results show improvement of the effluent quality after treatment with chitin and chitosan.
Resumo:
A neural network procedure to solve inverse chemical kinetic problems is discussed in this work. Rate constants are calculated from the product concentration of an irreversible consecutive reaction: the hydrogenation of Citral molecule, a process with industrial interest. Simulated and experimental data are considered. Errors in the simulated data, up to 7% in the concentrations, were assumed to investigate the robustness of the inverse procedure. Also, the proposed method is compared with two common methods in nonlinear analysis; the Simplex and Levenberg-Marquardt approaches. In all situations investigated, the neural network approach was numerically stable and robust with respect to deviations in the initial conditions or experimental noises.