464 resultados para cromatografia de íons
Resumo:
An analytical method based on high-performance liquid chromatography with electrochemical detection has been developed and applied to the determination of Solvent blue 14 (SA-14) and Solvent red 24 (SV-24) in fuel samples. The dyes were better separated on C18 column, using a mobile phase composed of acetonitrile and ammonium acetate (90:10, v/v). Detection was carried out at an oxidation potential of +0.85V. The detector response was linear at concentration range of 7.50×10-8 - 1.50×10-6 mol L-1 (r = 0.997) for SA-14 and SV-24, respectively. The method was used to quantify these dyes in fuels samples with satisfactory accuracy and precision.
Resumo:
An analytical method has been developed and validated for the determination of an association of ampicillins in a lyophilized powder for injection by HPLC. The advantage of chromatographic method other than the microbiological one is that, it is possible to monitor precisely, out-of-specification results in quality control processes and also during stability studies, in which an association of ampicillins is present. The proposed HPLC method was developed by using forced degraded samples, in order to reach a selective analysis of ampicillins when in the presence of their degradation products. It was possible to detect benzatine and through indirect calculation, to determine the ampicillin sodium in the drug sample. The method showed to be selective, accurate, precise, robust and linear (from 45.92 to 36.04 μg mL-1 of total ampicillin and from 14.53 to 43.28 μg mL-1 of benzatine). The accuracy determined from recovery test, gave results in the range of 99.41% of total ampicillin to 100.31% of benzatine. Hence, it can be concluded that the proposed HPLC method is applicable for ampicillins determination.
Resumo:
The present work purposes the preparation of a silica gel sorbent organically modified with 2-aminoethyl-3-aminobutylmethyldimethoxysilane (AAMDMS) and imprinted with Cu2+ ions by means surface imprinting technique and its use for selective on-line sorbent preconcentration of Cu2+ ions with further UV-VIS spectrophotometric determination by flow injection analysis. The Cu2+-imprinted silica gel, when compared with non imprinted silica gel and silica gel, showed from the binary mixture of Cu2+/Ni2+ relative selectivity coefficient (k') of 6.84 and 5.43 and 6.64 and 19.83 for the mixture Cu2+/Pb2+, thus demonstrating higher selectivity of Cu2+-imprinted silica gel towards Cu2+ ions. Under optimized condition, the on-line preconcentration method provided detection limit of 3.4 μg L-1 and linear range ranging from 30.0 up to 300.0 μg L-1 (r = 0.995). The accuracy of method was successfully assessed by analyzing different kind of spiked water samples with recovery values ranging from 92.2 up to 103.0%.
Resumo:
A simple ultra-performance liquid chromatographic method for the simultaneous determination of sildenafil citrate and tadalafil was developed and validated. Sample preparation was dissolution in methanol, followed by centrifugation and dilution (1:10) with methanol. Analysis was performed in an Acquity® UPLC system with Acquity® BEH C18 column (2.1 x 50 mm, with 1.7 μm particles). The elution was isocratic with phosphate buffer pH 2.3 and acetonitrile (65:35, v/v) at a flow rate of 0.7 mL/min. The method presented adequate specificity, linearity, precision and accuracy and allowed the determination of the drugs in seized forensic samples.
Resumo:
The development of modern analytical tools plays an important role in quality control. The main purpose of this study was to explore the use of subcritical water as a versatile analytical tool, employed simultaneously as a reagent and solvent, as well as the application of high temperature-high resolution gas chromatography (HT-HRGC) to develop a procedure for the analysis of triacylglycerides and fatty acids in Azadirachta indica A. Juss. (Neem) oil without the need for solvents, chemical reagents, or catalytic agents. The developed method presented satisfactory results and is in agreement with the concepts of Green Analytical Chemistry (GAC).
Resumo:
Activities related to nuclear industry, production of phosphoric acid and hospitals have generated considerable volumes of radioactive waste containing uranyl ions. Banana pith was characterized by Scanning Electron Microscopy and Fourier Transform Infrared Spectroscopy and was investigated as a biosorbent for uranyl ions from nitric solutions by batch experiments. Influences of adsorbent size, kinetics and equilibrium adsorption were studied. The biosorption of the uranyl ions followed pseudo-second-order kinetics. The adsorption isotherm data were closely fitted to the Freundlich equation.
Resumo:
The development of analytical methods for determination of eight pesticides of different chemical classes (trichlorfon, propanil, fipronil, propiconazole, trifloxystrobin, permethrin, difenoconazole and azoxystrobin) in sediments with gas chromatography-micro-electron capture detector (GC/µECD) and comprehensive two-dimensional gas chromatography with micro-electron capture detector (GCxGC/µECD) is described. These methods were applied to real sediment samples, and the best results were obtained using a 5% diphenyl-methylpolysiloxane column for 1D-GC. For GCxGC the same column was employed in the first dimension and a 50%-phenyl-methylpolysiloxane stationary phase was placed in the second dimension. Due to the superior peak capacity and selectivity of GCxGC, interfering matrix peaks were separated from analytes, showing a better performance of GCxGC.
Resumo:
This work shows results on the characterization, by liquid chromatography coupled to high resolution tandem mass spectrometry (LC-IT-TOF-MS) with electrospray ionization, of organic compounds present in raw and treated effluents from a combined sewage treatment systems (upflow anaerobic sludge blanket-trickling filter). The sewage samples were prepared by C18 solid phase extraction and the spectra obtained from the various extracts were submitted to principal component analysis to evaluate their pattern and identify the major deprotonated species. Some target compounds were submitted to semiquantitative analysis, using phenolphtalein as internal standard. The results showed the anaerobic step had little impact on the removal of anionic surfactants (LAS), fatty acids, and some contaminantes such as bisphenol A and bezafibrate, whereas the aerobic post-treatment was very efficient in removing these organics.
Resumo:
High-temperature liquid chromatography (HTLC) is a technique that presents a series of advantages in liquid phase separations, such as: reduced analysis time, reduced pressure drop, reduced asymmetry factors, modified retentions, controlled selectivities, better efficiencies and improved detectivities, as well as permitting green chromatography. The practical limitations that relate to instrumentation and to stationary phase instability are being resolved and this technique is now ready to be applied for routine determinations.
Resumo:
A method for ester content determination in soybean methyl biodiesel was studied, using ethyl oleate as internal standard. A biodiesel sample was analyzed and had its purity estimated as 92.8%. Method accuracy was evaluated by comparison with the result obtained via EN14103, with a relative difference of 0.1%. Repetitivity and intermediate precision were estimated as 2 and 1.5%, respectively.
Resumo:
Cellulose acetate polymeric membranes had been prepared by a procedure of two steps, combining the method of phase inversion and the technique of hydrolysis-deposition. The first step was the preparation of the membrane, and together was organomodified with tetraethylortosilicate and 3-aminopropyltrietoxysilane. Parameters that exert influence in the complexation of the metallic ion, as pH, time of complexation, metal concentration, had been studied in laboratory using tests of metal removal. The membranes had presented resistance mechanics and reactivity to cations, being able to be an alternative for the removal, daily pay-concentration or in the study of the lability of metals complexed.
Resumo:
The organic acids (tartaric, malic, citric, lactic and succinic) are de main components responsible for the acidity in the wine. This method for simultaneous determination of organic acids and interfering peaks in wines can be achieved in 16 min. The sample preceded by a dilution and filtration step. The chromatographic separation required one reversed phase column, isocratic mobile phase (acetonitrila, formic acid in water) and detection wavelength was set at 212 nm. The validation confirmed good repeatability, recovery and application in red and white wines.
Resumo:
For this study, magnetic composite of zeolite-magnetite was prepared by mixing magnetite nanoparticles suspension with synthetic zeolite. The nanoparticles in suspension were synthesized by precipitating iron ions in a NaOH solution. The zeolite was synthesized from coal fly ash by alkaline hydrothermal treatment. The magnetic composite was characterized by XDR, SEM, magnetization measurements, IR, and BET surface area. Batch tests were carried out to investigate the adsorption of metal ions of Zn2+, Cd2+ and Pb2+ from aqueous solution onto magnetic composite. Adsorption isotherms were analyzed using Freundlich and Langmuir equations. The adsorption equilibrium data fitted well to the Langmuir equation with maximum adsorption capacities in the range of 28.5-127 mg g-1.
Resumo:
The potential use of rice husk as biosorbent to remove Cu2+, Al3+, Ni2+ and Zn2+ ions from aqueous solutions was investigated under both noncompetitive and competitive conditions. The biosorbent was used in the form of particles with size smaller than 0.5 μm and in the concentration of 500 mg L-1 (dry weight). The experiments were performed using batch adsorption technique for concentrations of 10, 30 and 70 mg L-1 of metal ions at pH 4.0 and 5.0. The chemical speciation of metals in the experimental conditions used in this work was predicted by the software Visual MINTEQ 2.6.
Resumo:
This review first discusses the limitations of many of the supports and stationary phases used in reversed phase high performance liquid chromatography and then describes those, developed more recently, that present better stabilities and more versatile selectivities. Emphases will be given to stationary phases that use higher purity silicas, hybrid silicas, monolithic silicas, metallic oxides and mixed oxides as supports and those that have embedded polar groups or contain phenyl or fluoro groups as the stationary phase as well as the phases used for mixed mode or hydrophilic interaction separations. These modern stationary phases facilitate the analysis of complex mixtures.