212 resultados para PULMONARY-ARTERY DIAMETERS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare the effects of 3 types of noninvasive respiratory support systems in the treatment of acute pulmonary edema: oxygen therapy (O2), continuous positive airway pressure, and bilevel positive pressure ventilation. METHODS: We studied prospectively 26 patients with acute pulmonary edema, who were randomized into 1 of 3 types of respiratory support groups. Age was 69±7 years. Ten patients were treated with oxygen, 9 with continuous positive airway pressure, and 7 with noninvasive bilevel positive pressure ventilation. All patients received medicamentous therapy according to the Advanced Cardiac Life Support protocol. Our primary aim was to assess the need for orotracheal intubation. We also assessed the following: heart and respiration rates, blood pressure, PaO2, PaCO2, and pH at begining, and at 10 and 60 minutes after starting the protocol. RESULTS: At 10 minutes, the patients in the bilevel positive pressure ventilation group had the highest PaO2 and the lowest respiration rates; the patients in the O2 group had the highest PaCO2 and the lowest pH (p<0.05). Four patients in the O2 group, 3 patients in the continuous positive pressure group, and none in the bilevel positive pressure ventilation group were intubated (p<0.05). CONCLUSION: Noninvasive bilevel positive pressure ventilation was effective in the treatment of acute cardiogenic pulmonary edema, accelerated the recovery of vital signs and blood gas data, and avoided intubation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVE: Antihypertensive therapy with thiazides decreases coronary events in elderly patients. However, the influence of diuretics on myocardial ischemia has not been fully investigated. The aim of this study was to compare the effect of chlorthalidone and diltiazem on myocardial ischemia. METHODS: Following a randomized, double-blind, crossover protocol, we studied 15 elderly hypertensive patients aged 73.6±4.6 years with myocardial ischemia. All patients had angiographically documented coronary artery disease. We measured patients using 48- hour ambulatory electrocardiogram monitoring and exercise testing. After a 2-week period using placebo, patients received chlorthalidone or diltiazem for 4 weeks. RESULTS: Both treatments lowered systolic and diastolic blood pressures. The number of ischemic episodes on ambulatory electrocardiogram recordings was reduced with the use of chlorthalidone (2.5±3.8) and diltiazem (3.2±4.2) when compared with placebo (7.9±8.8; p<0.05). The total duration of ischemic episodes was reduced in both treatments when compared with placebo (chlorthalidone: 19.2±31.9min; diltiazem: 19.3±29.6min; placebo: 46.1±55.3min; p<0.05). CONCLUSION: In elderly hypertensive patients with coronary artery disease, chlorthalidone reduced myocardial ischemia similarly to diltiazem. This result is consistent with epidemiological studies and suggests that reduction of arterial blood pressure with thiazide therapy plays an important role in decreasing myocardial ischemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report 2 cases of transposition of the great arteries associated with anomalous pulmonary venous connection emphasizing the clinical findings, the diagnosis, and the evolution of the association. One of the patients had the anomalous pulmonary venous connection in its total infradiaphragmatic form, in the portal system, and the other patient had a partial form, in which an anomalous connection of the left superior lobar vein with the innominate vein existed. At the time of hospital admission, the patients had cyanosis and respiratory distress with clinical findings suggesting transposition of the great arteries. The diagnosis in 1 of the cases, in which the anomalous connection was partial, was established only with echocardiography, without invasive procedures that would represent risk for the patient; in the other case, in which the anomalous connection was total, the malformation was only evidenced with catheterization. The patients underwent surgery for anatomical correction of the heart disease. Only 1 patient had a good outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The association between cytokines and troponin-I with cardiac function after cardiac surgery with cardiopulmonary bypass remains a topic of continued investigation. METHODS: Serial measurements, within 24h following surgery, of tumor necrosis factor-alpha, its soluble receptors, and troponin-I were performed in patients with normal ejection fraction undergoing coronary artery bypass grafting. Ejection fraction was measured by radioisotopic ventriculography preoperatively, at 24h and at day 7 postoperatively. RESULTS: Of 19 patients studied (59±8.5 years), 10 (group 1) showed no changes in ejection fraction, 53±8% to 55±7%, and 9 (group 2) had a decrease in ejection fraction, 60±11% to 47±11% (p=0.015) before and 24h after coronary artery bypass grafting, respectively. All immunological variables, except tumor necrosis factor-alpha soluble receptor I at 3h postoperation (5.5± 0.5 in group 1 versus 5.9±0.2 pg/ml in group 2; p=0.048), were similar between groups. Postoperative troponin-I had an inverse correlation with ejection fraction at 24h (r= -0.44). CONCLUSIONS: Inflammatory activity, assessed based on tumor necrosis factor-alpha and its receptors, appears to play a minor role in cardiac dysfunction after cardiac surgery. Troponin I levels are inversely associated with early postoperative ejection fraction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare inverted-L mini-sternotomy performed above the sternal furcula with conventional sternotomy in patients with aortic valve diseases who undergo surgical treatment. METHODS: We operated upon 30 patients who had aortic valve lesions that had clinical and hemodynamic findings. All patients underwent inverted-L sternotomy, which extended from above the manubrium of the sternum to the 3rd right intercostal space, without opening the pleural cavity. Their ages ranged from 32 to 76 years, and 18 were males and 12 were females. We used negative pressure in a venous ¼-inch cannula, and the patients were maintained in Trendelemburg's position. Twenty-seven patients received bioprostheses with diameters ranging from 23 to 29mm. Three patients underwent only removal of the calcifications of the aortic valve leaflets and aortic commissurotomy. RESULTS: The mean duration of anoxic cardiac arrest was 63.11min. Access was considered good in all patients. One death was due to pulmonary and renal problems not related to the incision. All patients had a better recovery in the intensive care unit, got out of bed sooner, coughed more easily, and performed prophylactic physiotherapeutic maneuvers for respiratory problems more easily and with less pain in the incision. Early ambulation was more easily carried out by all patients. CONCLUSION: Mini-sternotomy proved to be better than the conventional sternotomy because it provided morecomfort for the patients in the early postoperative period, with less pain and greater desire for early ambulation and all its inherent advantages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To study the arrangement of the myocardial fiber bundles at the pulmonary venous left atrial junction in patients with pulmonary hypertension, and to discuss the pathophysiological importance of this element in the etiology of acute pulmonary edema. METHODS: We obtained 12 hearts and their pulmonary vein extremities from postmortem examinations of patients with the anatomicopathological diagnosis of acute pulmonary edema. The specimens, which had no grossly visible morphological cardiac alterations, were fixed in 10% formalin, and the muscular arrangement of the pulmonary venous left atrial junctions was analyzed. This material was then isolated, embedded in paraffin, underwent serial cutting (50 µm of thickness), and was stained with Azam's trichrome. RESULTS: We observed in our specimens that: a) the myocardial fiber bundles that originate in the atrial wall and involve the openings of the pulmonary veins were fewer than those observed in healthy material; b) the myocardial fiber bundles that extend into the pulmonary veins were shorter than those found in material originating from individuals with no pulmonary hypertension. CONCLUSION: Anatomical changes that result in a reduction in the amount of myocardial fiber bundles in the pulmonary venous left atrial junction, isolated or associated with other factors, may be the cause of disorders in pulmonary circulation, leading to an increase in pulmonary venous pressure, and, consequently, to acute pulmonary edema.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate elastic properties of conduit arteries in asymptomatic patients who have severe chronic aortic regurgitation. METHODS: Twelve healthy volunteers aged 30±1 years (control group) and 14 asymptomatic patients with severe aortic regurgitation aged 29±2 years and left ventricular ejection fraction of 0.61±0.02 (radioisotope ventriculography) were studied. High-resolution ultrasonography was performed to measure the systolic and diastolic diameters of the common carotid artery. Simultaneous measurement of blood pressure enabled the calculation of arterial compliance and distensibility. RESULTS: No differences were observed between patients with aortic regurgitation and the control group concerning age, sex, body surface, and mean blood pressure. Pulse pressure was significantly higher in the aortic regurgitation group compared with that in the control group (78±3 versus 48±1mmHg, P<0.01). Arterial compliance and distensibility were significantly greater in the aortic regurgitation group compared with that in the control group (11.0±0.8 versus 8.1±0.7 10-10 N-1 m4, P=0.01 e and 39.3±2.6 versus 31.1±2.0 10-6 N-1 m², P=0.02, respectively). CONCLUSION: Patients with chronic aortic regurgitation have increased arterial distensibility. Greater vascular compliance, to lessen the impact of systolic volume ejected into conduit arteries, represents a compensatory mechanism in left ventricular and arterial system coupling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of a 3-year-old female patient, who, since birth, had cyanosis difficult to explain with usual diagnostic tests. The only findings on physical examination were cyanosis and clubbing of her fingers. Chest computerized tomography showed images of excessive attenuation in the right lung, which resembled arteriovenous fistulae that were later confirmed on cardiac catheterization. The fistulous trajectories were then embolized with 7 Gianturco coils, which resulted in an immediate increase in the arterial saturation of blood oxygen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To demonstrate the feasibility and safety of simultaneous catheterization and mapping of the 4 pulmonary veins for ablation of atrial fibrillation. METHODS: Ten patients, 8 with paroxysmal atrial fibrillation and 2 with persistent atrial fibrillation, refractory to at least 2 antiarrhythmic drugs and without structural cardiopathy, were consecutively studied. Through the transseptal insertion of 2 long sheaths, 4 pulmonary veins were simultaneously catheterized with octapolar microcatheters. After identification of arrhythmogenic foci radiofrequency was applied under angiographic or ultrasonographic control. RESULTS: During 17 procedures, 40 pulmonary veins were mapped, 16 of which had local ectopic activity, related or not with the triggering of atrial fibrillation paroxysms. At the end of each procedure, suppression of arrhythmias was obtained in 8 patients, and elimination of pulmonary vein potentials was accomplished in 4. During the clinical follow-up of 9.6±3 months, 7 patients remained in sinus rhythm, 5 of whom were using antiarrhythmic drugs that had previously been ineffective. None of the patients had pulmonary hypertension or evidence of stenosis in the pulmonary veins. CONCLUSION: Selective and simultaneous catheterization of the 4 pulmonary veins with microcatheters for simultaneous recording of their electrical activity is a feasible and safe procedure that may help ablation of atrial fibrillation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report new percutaneous techniques for perforating the pulmonary valve in pulmonary atresia with intact ventricular septum, in 3 newborns who had this birth defect. There was mild to moderate hypoplastic right ventricle, a patent infundibulum, and no coronary-cavitary communications. We succeeded in all cases, and no complications related to the procedure occurred. The new coaxial radiofrequency system was easy to handle, which simplified the procedure. Two patients required an additional source of pulmonary flow (Blalock-Taussig shunt) in the first week after catheterization. All patients had a satisfactory short-term clinical evolution and will undergo recatheterization within 1 year to define the next therapeutic strategy. We conclude that this technique may be safely and efficiently performed, especially when the new coaxial radiofrequency system is used, and it may become the initial treatment of choice in select neonates with pulmonary atresia and intact ventricular septum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - To determine the risk factors prevalence for coronary artery disease in the State of Rio Grande do Sul, Brazil and to identify their relation with the age bracket. METHODS - We carried out an observational, cross-sectional study of 1,066 adults older than 20 years in the Brazilian State of Rio Grande do Sul. We investigated the risk factors: familial antecedents, systemic arterial hypertension, high levels of cholesterol and glycemia, overweight/obesity, smoking and sedentary lifestyle. A standardized questionnaire completed at the patients' dwellings by health agents were used; the data were stored in an EPI-INFO software database. The results were expressed with a 95% confidence interval. RESULTS - The sample composition was of 51.8% females. The risk factors prevalences were: 1) sedentary lifestyle 71.3%; 2) familial antecedents: 57.3%; 3) overweight/obesity (body mass index >25): 54.7%; 4) smokers: 33.9%; 5) hypertension: 31.6% (considering >140/90mmHg) and 14.4% (considering >160/95mmHg); 6) high glycemia (>126 mg/dL): 7%; 7) high cholesterol >240 mg/dL): 5.6%. CONCLUSION - The prevalence of the major risk factors for coronary artery disease in the Brazilian state of Rio Grande do Sul could be determined in a study that integrated public and private institutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An atherosclerotic aneurysm of the right coronary artery complicated by a recent myocardial infarction was successfully treated with coronary artery stenting, using a device consisting of 2 stents with a layer of expandable polytetrafluorethylene (PTFE) placed between them. A follow-up angiograph 5 months after the procedure showed sustained initial results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The case of a 16-year-old patient with atrioventricular tachycardia caused by a single left anterolateral accessory pathway is reported. When the patient underwent radiofrequency ablation, a lesion on the mitral annulus lateral wall produced changes in the retrograde atrial activation pattern determined by that pathway; changes ranged from a delay in depolarization of the annulus posterior portions to full left atrium counterclockwise activation. Such phenomena were probably caused by a block in the isthmus between the annulus and the lower left pulmonary vein ostium. This case illustrates the importance of the mitral-pulmonary isthmus in the process of left atrium activation, an alert to changes induced by its unintentional block during accessory pathway ablation.