146 resultados para Flow Resistance
Resumo:
To establish an insecticidal resistance surveillance program, Culex quinquefasciatus mosquitoes from São Paulo, Brazil, were colonized (PIN95 strain) and analyzed for levels of resistance. The PIN95 strain showed low levels of resistance to organophosphates [malathion (3.3-fold), fenitrothion (11.2-fold)] and a carbamate [propoxur (3.0-fold)]. We also observed an increase of 7.4 and 9.9 in a and b esterase activities, respectively, when compared with the reference IAL strain. An alteration in the sensitivity of acetylcholinesterase to insecticide inhibition was also found in the PIN95 mosquitoes. The resistant allele (Ace.1R), however, was found at low frequencies (0.12) and does not play an important role in the described insecticide resistance. One year later, Cx. quinquefasciatus mosquitoes were collected (PIN96 strain) at the same site and compared to the PIN95 strain. The esterase activity patterns observed for the PIN96 strain were similar to those of the PIN95 mosquitoes. However the occurrence of the Ace.1R allele was statistically higher in the PIN96 strain. The results show that esterase-based insecticide resistance was established in the PIN95 Cx. quinquefasciatus population and that an acethylcholinesterase based resistant mechanism has been selected for. A continuous monitoring of this phenomenon is fundamental for rational mosquito control and insecticide application programs.
Resumo:
The purpose of this study was to analyze the prevalence and risk factors for drug resistance among hospitalized patients in two tertiary care centers, an acquired immunodeficiency syndrome (AIDS) reference center and a sanatorium, in Rio de Janeiro, Brazil. From 1993-1994, 389 patients were diagnosed as having tuberculosis (TB). Isolates from 265 patients were tested for in vitro susceptibility to rifampin and isoniazid. Resistance to one or more drugs was detected in 44 patients (16.6%) and was significantly more common among recurrent cases in both hospitals (p=0.03 in the AIDS center and p=0.001 in the sanatorium). Twenty seven patients (10.2%) had isolates resistant to both isoniazid and rifampin. Multi-drug resistance was associated with human immunodeficiency virus (HIV) infection among patients who had never been treated for TB. In conclusion, drug-resistant TB is high in hospitalized patients in Rio de Janeiro, especially among HIV infected patients. Therefore, measures to control TB and prevent nosocomial transmission need urgently to be set up in the Brazilian hospitals.
Resumo:
The intestinal microbiota, a barrier to the establishment of pathogenic bacteria, is also an important reservoir of opportunistic pathogens. It plays a key role in the process of resistance-genes dissemination, commonly carried by specialized genetic elements, like plasmids, phages, and conjugative transposons. We obtained from strains of enterobacteria, isolated from faeces of newborns in a university hospital nursery, indication of phenothypical gentamicin resistance amplification (frequencies of 10-3 to 10-5, compatible with transposition frequencies). Southern blotting assays showed strong hybridization signals for both plasmidial and chromossomal regions in DNA extracted from variants selected at high gentamicin concentrations, using as a probe a labeled cloned insert containing aminoglycoside modifying enzyme (AME) gene sequence originated from a plasmid of a Klebsiella pneumoniae strain previously isolated in the same hospital. Further, we found indications of inactivation to other resistance genes in variants selected under similar conditions, as well as, indications of co-amplification of other AME markers (amikacin). Since the intestinal environment is a scenario of selective processes due to the therapeutic and prophylactic use of antimicrobial agents, the processes of amplification of low level antimicrobial resistance (not usually detected or sought by common methods used for antibiotic resistance surveillance) might compromise the effectiveness of antibiotic chemotherapy.
Resumo:
Human immunodeficiency virus (HIV) infection heavily compromises the immune system. The decrease of the T cell CD4+ subset along the evolution to acquired immunodeficiency syndrome has been considered as a hallmark of HIV infection. In this paper we review some aspects of the immunopathology of HIV infection and discuss the importance of the flow cytometry for the evaluation of the T lymphocyte subsets in the follow-up of HIV infected children and adults, and for the monitoring of the immune reconstitution upon antiretroviral therapy.
Resumo:
Flow cytometry has been used as a powerful technique for studying cell surface antigen expression as well as intracellular molecules. Its capability of analyzing multiple parameters simultaneously on a single cell has allowed identification and studies of functional cell subsets within heterogeneous populations. In this respect, several techniques have been developed during the past few years to study cytokine-producing cells by flow cytometry in humans and several animal models.
Resumo:
Applications of flow cytometry to clinical and experimental hematopoietic stem cell transplantation (HSCT) are discussed in this review covering the following topics: diagnosis and classification of lymphohematologic disorders, quantitation of hematopoietic progenitors in the graft, lymphohematopoietic reconstitution following HSCT and animal models of human HSCT. At the end, the utilization of flow cytometry in clinical HSCT by Brazilian transplant centers is briefly reviewed.
Resumo:
The expression of P2Z/P2X7 purinoceptor in different cell types is well established. This receptor is a member of the ionotropic P2X receptor family, which is composed by seven cloned receptor subtypes (P2X1 - P2X7). Interestingly, the P2Z/P2X7 has a unique feature of being linked to a non-selective pore which allows the passage of molecules up to 900 Da depending on the cell type. Early studies of P2Z/P2X7 purinoceptor were exclusively based on classical pharmacological studies but the recent tools of molecular biology have enriched the analysis of the receptor expression. The majority of assays and techniques chosen so far to study the expression of P2Z/P2X7 receptor explore directly or indirectly the effects of the opening of P2Z/P2X7 linked pore. In this review we describe the main techniques used to study the expression and functionality of P2Z/P2X7 receptor. Additionally, the increasing need and importance of a multifunctional analysis of P2Z/P2X7 expression based on flow cytometry technology is discussed, as well as the adoption of a more complete analysis of P2Z/P2X7 expression involving different techniques.
Resumo:
In this report we present a concise review concerning the use of flow cytometric methods to characterize and differentiate between two different mechanisms of cell death, apoptosis and necrosis. The applications of these techniques to clinical and basic research are also considered. The following cell features are useful to characterize the mode of cell death: (1) activation of an endonuclease in apoptotic cells results in extraction of the low molecular weight DNA following cell permeabilization, which, in turn, leads to their decreased stainability with DNA-specific fluorochromes. Measurements of DNA content make it possible to identify apoptotic cells and to recognize the cell cycle phase specificity of apoptotic process; (2) plasma membrane integrity, which is lost in necrotic but not in apoptotic cells; (3) the decrease in forward light scatter, paralleled either by no change or an increase in side scatter, represent early changes during apoptosis. The data presented indicate that flow cytometry can be applied to basic research of the molecular and biochemical mechanisms of apoptosis, as well as in the clinical situations, where the ability to monitor early signs of apoptosis in some systems may be predictive for the outcome of some treatment protocols.
Resumo:
The author describes and make comments on the favorable conditions that made possible the creation and organization of the first laboratory of flow cytometry in Brazil and South America installed at the Oswaldo Cruz Institute-Fiocruz, Rio de Janeiro, in November 1988.