196 resultados para BR-174
Resumo:
Objective To develop procedures to ensure consistency of printing quality of digital images, by means of hardcopy quantitative analysis based on a standard image. Materials and Methods Characteristics of mammography DI-ML and general purpose DI-HL films were studied through the QC-Test utilizing different processing techniques in a FujiFilm®-DryPix4000 printer. A software was developed for sensitometric evaluation, generating a digital image including a gray scale and a bar pattern to evaluate contrast and spatial resolution. Results Mammography films showed maximum optical density of 4.11 and general purpose films, 3.22. The digital image was developed with a 33-step wedge scale and a high-contrast bar pattern (1 to 30 lp/cm) for spatial resolution evaluation. Conclusion Mammographic films presented higher values for maximum optical density and contrast resolution as compared with general purpose films. The utilized digital processing technique could only change the image pixels matrix values and did not affect the printing standard. The proposed digital image standard allows greater control of the relationship between pixels values and optical density obtained in the analysis of films quality and printing systems.
Resumo:
Objective Undertaking of a complete audit of the service of mammography, as recommended by BI-RADS®, in a private reference institution for breast cancer diagnosis in the city of São Paulo, SP, Brazil, and comparison of results with those recommended by the literature. Materials and Methods Retrospective, analytical and cross-sectional study including 8,000 patients submitted to mammography in the period between April 2010 and March 2011, whose results were subjected to an internal audit. The patients were followed-up until December 2012. Results The radiological classification of 7,249 screening mammograms, according to BI-RADS, was the following: category 0 (1.43%), 1 (7.82%), 2 (80.76%), 3 (8.35%), 4 (1.46%), 5 (0.15%) and 6 (0.03%). The breast cancer detection ratio was 4.8 cases per 1,000 mammograms. Ductal carcinoma in situ was found in 22.8% of cases. Positive predictive values for categories 3, 4 and 5 were 1.3%, 41.3% and 100%, respectively. In the present study, the sensitivity of the method was 97.1% and specificity, 97.4%. Conclusion The complete internal audit of a service of mammography is essential to evaluate the quality of such service, which reflects on an early breast cancer detection and reduction of mortality rates.
Resumo:
Objetivo: O objetivo deste trabalho é avaliar a dose em pacientes submetidos a PET/CT para diagnóstico de comprometimento cognitivo leve. Materiais e Métodos: Para as medidas da dose absorvida proveniente da modalidade CT utilizaram-se detectores TLD-100 inseridos em um simulador Alderson Rando®. Os simuladores antropomórficos (versões masculina e feminina) foram submetidos aos mesmos protocolos técnicos para aquisição das imagens dos pacientes. A dose absorvida resultante da injeção do radiofármaco foi estimada por meio do modelo proposto pela ICRP 106. Resultados: A dose efetiva a que foram submetidos os pacientes com esta técnica diagnóstica foi, aproximadamente, (5,34 ± 1,99) mSv. Conclusão: Protocolos otimizados para cálculo de atividade radioativa que será injetada em cada paciente podem contribuir para a redução da dose efetiva nos pacientes durante a realização do diagnóstico de comprometimento cognitivo leve com PET/CT.
Resumo:
The series of compounds cis-[Fe(CO)4(HgX)2], X=Cl,Br,I shows an octahedral geometry around the iron atom with the two HgX groups cis to each other. In this paper the assignment for the carbonyl stretching modes and the calculation of their force constants were performed on the basis of the Cotton-Krainhanzel model. Taking into account all the data from the IR, 199Hg NMR and UV-vis spectra it is possible to verify the influence of X on the electronic densities at the metallic centers.
Resumo:
A new titrimetric method for the determination of phosphite in fertilizer samples, based on reaction of H3PO3 with standard iodine solution in neutral media, is proposed. Diluted samples containing ca. 0.4% m/v P2O5 are heated and titrated with 0.05 mol L-1 iodine standard until the solution becomes faint yellow. Back titration is also feasible: a slight excess of titrant is added followed by starch indicator and titration is completed taking as the end point the change in color from blue to colorless. The influence of chemical composition and pH of buffers, temperature and foreign species on waiting time and end-point detection were investigated. For the Na2HPO4/NaH2PO4 buffer (pH 6.8) at 70 °C, the titration time was 10 min, corresponding to about 127 mg iodine, 200 mg KI and 174 mg Na2HPO4 and 176 mg NaH2PO4 consumed per determination. Accuracy was checked for phosphite determination in seven fertilizer samples. Results obtained by the proposed procedure were in agreement with those obtained by spectrophotometry at 95% confidence level. The R.S.D. (n=10) for direct and back titration was 0.4% and 1.3% respectively.
Resumo:
This work had as objective verified the term-stability of the Soxhlet modified system with analytical and pharmacothecnical application in extractive processes of Nasturtium officinale. It has proven that the process is thermo-stable. The analysis with analytical have determined 3.606 mg g-1 in chlorogenic acid and 11.813 mg g-1 in rutin (extract 1:20 w/v) and with pharmacotecnical 3.427 mg g-1 in chlorogenic acid and 11.278 mg g-1 in rutin (extract 1:6 w/v). The income of the pharmacothecnical process was inferior to the analytical, suggesting that the pharmacothecnical process would need of at least the double of time in each extraction system.
Resumo:
Among other applications, Ipomoea pes-caprae is popularly used to treat jellyfish stings, supporting the development of a product for dermatological use. Hydroethanolic spray-dried extract was chosen for the further development of phytomedicines, and a stability-indicative HPLC-UV method was developed and validated for the determination of isoquercitrin and isochlorogenic acids A, B and C. The method was developed using a C18 column (250 x 4.6 mm, 5 µm) with an acetonitrile:water mobile phase at pH 3.0 in a gradient run. The four constituents and other unidentified components of the extract were appropriately resolved without interference of degradation products after stress tests (acid, alkali, neutral, oxidant, photolysis). The method showed linearity in the isoquercitrin concentration range from 5.0-50.0 µg mL-1, with adequate precision (RSD% < 2.5% for the intra- and inter-day studies), accuracy (recovery of 100.0 ± 2.0%), and robustness. Both the herbal drug and spray-dried extract of I. pes-caprae were subjected to stability studies in accelerated and long-term conditions over four months. The samples maintained their characteristics and marker contents (< 10% of variation).
Resumo:
Numerous investigations are dedicated to the research and development of new polymer materials destined for innovation in pharmaceutical forms. The application of these technological resources has allowed the commercialization of new therapeutic systems for modified drug release. This investigation aimed to evaluate the association of modified chondroitin sulfate with an insoluble polymer, Eudragit® RS 30 D, widely available in the pharmaceutical market. Isolated films were prepared by the evaporation process using a Teflon® plate. The aqueous dispersions (4% m/v) of synthetic polymer received the addition of modified chondroitin sulfate at different ratios. The interactions of the polymer chains in the blends were physicochemically characterized by means of Fourier transform infrared spectroscopy, thermal analyses, differential scanning calorimetry, thermogravimetry and scanning electron microscopy combined with hydration and assays in alkaline pH. The results showed appropriate properties of the coating materials for solid oral forms intended for drug deliver in specific environments.
Resumo:
Specimens of Leonotis nepetiflolia were obtained from cultivated and wild environments to verify their influences in chemical composition. Phytochemical analyses were conducted for the ethyl acetate phase obtained by partitioning the crude ethanol extract from the cultivated leaves of L. nepetifolia. In doing so, flavonoid 3',4',5-trimethoxy-6,7-dihidroxyflavone (cirsiliol), a chemotaxonomic marker of the family Lamiaceae, was isolated. The results reveal that all phases and extracts tested exhibited weak to moderate antimicrobial activity against the strains of bacteria tested. The evaluation of in vitrocytotoxic and antitumor activity showed that the ethyl acetate phases obtained from both wild and cultivated leaves exhibit high potential cytotoxic and antitumor (> 78.0% of inhibition) activity. The major component of these phases was identified by high-performance liquid chromatography-diode array detector and nuclear magnetic resonance analyses using both 1D and 2D methods. The results further indicate that the flavonoid cirsiliol is the agent responsible for the activity observed in these phases.
Resumo:
Heterobimetallic carbonyl compounds of the type [Fe(CO)4(HgX)2] (X= Cl, Br, I), which have metal-metal bonds, have been prepared in order to study their thermal stabilities as a function of the halogen coordinated to mercury atoms. The characterization of the above complexes was carried out by elemental analysis, IR and NMR spectroscopies. Their thermal behaviour has been investigated and the final product was identified by IR spectroscopy and by X-ray powder diffractogram.
Resumo:
In this paper, a new, simple and sensitive method for arsenic determination in soil is proposed. This is based on the reduction of silver (I) and iron (III) ions by arsine followed by a complexation reaction of iron (II) with the spectrophotometric reagent Br-PADAP 2-(5-bromo-2-pyridylazo)-5-di-ethylaminophenol. Arsenic determination with a Sandell's sensitivity of 3.1 10-4 cm-2, linear range from 0.1 µg ml-1 to 2.0 µg ml-1 (r560 = 0.9995), molar absorptivity of 2.45 10(5) l mol-1 cm-1 and a concentration detection limit of 1.4 ng ml-1 (3s) were obtained using a 10 ml sample volume. Selectivity was increased with the use of EDTA as a masking agent. The proposed method was applied for arsenic determination in the presence of several ions amounts in digested soil samples. The results revealed that antimony (III), mercury (II), germanium (IV), platinum (IV) interferes at all analyzed proportions. The interferences can be easily removed by the use of EDTA. Precision and accuracy obtained were satisfactory with a R.S.D. < 5 %. Recovery of arsenic in soil samples varied from 95.55 to 102.70 % with a mean of 99.63 %. These results demonstrated that the proposed method is applicable for arsenic analysis in different soil samples.
Resumo:
OBJETIVO: Analisar o perfil e a produção científica de pesquisadores da área da Pediatria contemplados com bolsas de produtividade em pesquisa pelo Conselho Nacional de Desenvolvimento Científico e Tecnológico. MÉTODOS: Foram analisados os currículos Lattes de 47 pesquisadores da Pediatria, com bolsas ativas no triênio 2010-2012. As variáveis analisadas foram: gênero, categoria do bolsista, instituição de origem, artigos nacionais e internacionais com o respectivo Qualis, publicações de livros e capítulos de livros, orientações de iniciação científica, mestrado e doutorado e produção de patente. RESULTADOS: Houve predominância do gênero masculino (66%) e de bolsistas na categoria 2 (51%) entre os pesquisadores da área da Pediatria. Os Estados de São Paulo, Rio Grande do Sul e Minas Gerais foram responsáveis por aproximadamente 90% dos pesquisadores. Os bolsistas em Pediatria publicaram no triênio estudado 1.174 artigos, sendo que 274 foram veiculados em periódicos com classificação Qualis B2. CONCLUSÕES: Os pesquisadores na área da Pediatria apresentam produção científica relevante do ponto de vista quantitativo. Entretanto, novos estudos são necessários para dimensionar o impacto do aumento da produção científica na área de Pediatria no País.
Resumo:
Introdução A simulação é uma metodologia usada para substituir ou amplificar experiências reais por experiências guiadas que evocam ou replicam aspectos do mundo real de maneira interativa. A simulação in situ leva essa técnica diretamente aos locais onde ocorrem atendimentos, com a própria equipe de saúde atuando em seu ambiente de trabalho em cenário simulado. Objetivo Descrever experiência piloto de simulação in situ realizada em unidade de pronto atendimento, destacando oportunidades de avaliação de sistema de atendimento, trabalho em equipe e detecção de ameaças latentes à segurança (ALS). Métodos Estudo aplicado na Unidade Ibirapuera do Hospital Israelita Albert Einstein e realizado pelo Centro de Simulação Realística Albert Einstein. Foi apresentado cenário de paciente de 45 anos com síndrome coronariana aguda que evolui para parada cardiorrespiratória. Simulação híbrida de 30 minutos com uso de ator e simulador de alta fidelidade (SimMan 3G®).Utilizado checklist e filmagem para avaliar habilidades e atitudes, usados em debriefing estruturado com uma hora de duração. Resultados A experiência proporcionou avaliação técnica, comportamental e sistemas. Detectou quatro ALS e permitiu reflexão guiada sobre trabalho em equipe. Conclusão Este piloto contribuiu para o alcance dos objetivos propostos com o cenário e demonstrou oportunidades de treinamento e melhoria. A simulação in situ pode ser usada no futuro sistematicamente para treinamento contínuo de equipes, visando à melhoria da qualidade de atendimento e à segurança do paciente.