131 resultados para sodium hydroxide (NaOH)
Resumo:
The evaluation of filtration methods on the yield and oleochemicals characteristics on the crude fish oil from the soapstock of marine fish for purposes of nutrition has been conducted in this work. The analytical properties of the crude and the neutralized oil with three excesses of sodium hydroxide (NaOH, 20%, 40% and 60%) were carried out on two different ways with organza and the “glass wool”. The neutralization of the oil brought about a notable improvement in the analytical properties of the oil. Thus, it leads to a high quality fish oil in terms of taste, colour, odours, shelf life and market value. Based on the improved characteristics of the oil, it could be suitable for applications in pharmaceutical and food industries.
Resumo:
For the determination of exchangeable hydrogen ion in soils, the authors of the presente work made the extraction with normal calcium acetate solution that may have an initial pH between 7 and 8 without altering the amount of hydrogen ion extracted. The extraction was made by shaking 5,0 grams of air dry soil with 100 ml of normal calcium acetate solution, the pH of wich was ascertained to 7,0, 7,5 and 8,0 with acetic acid, in 250 mil conical flasks for 30 minutes in a Wagner shaker (30-40 rpm). The contents of the flasks were then, filtered. A 50 ml aliquot of each of the leachate was titrated with a 0,020 N NaOH solution and the volumes consumed sodium hydroxide were ploted against pH. The titration curves thus obtained showed to be straight lines between pH 8 and 9 and parallel to the curve obtained by the titration of the blank. Two ways of locating the end point of the titration showed to be possible: the use of a pHmeter or titrimeter or the use of phenolphtalein as indicator. When using a pH meter or a titrimeter, the end point may rest in any point between pH 8 and 9, and the volume of sodium hydroxide consumed is found by comparison with a similar curve obtained by the titration of the blank. When using phenolphtalein the calcium acetate solution must have a pH below 8.
Resumo:
In this work a method was developed for removing metallic ions from wastewaters by co-precipitation of Cu2+, Pb2+, Cd2+, Cr3+ and Hg2+ with chitosan and sodium hydroxide solution. Solutions of these metallic ions in the range from 0.55 to 2160 mg L-1 were added to chitosan dissolved in 0.05 mol L-1 HCl. For the co-precipitation of metal-chitosan-hydroxide a 0.17 mol L-1 NaOH solution was added until pH 8.5-9.5. A parallel study was carried out applying a 0.17 mol L-1 NaOH solution to precipitate those metallic ions. Also, a chitosan solid phase column was used for removing those metallic ions from wastewaters.
Resumo:
The purpose of this study was to evaluate the influence of variables in a flotation technique for the recovery of Toxocara canis eggs from soil. The trials were done under standardized conditions on one gram of previously sterilized soil samples contaminated with 200 eggs of T. canis. The following variables were evaluated in serial steps: sieving; type of wash; time of stirring; resuspension of sediment; solution flotation. Centrifuge-flotation in sodium nitrate (d = 1.20 g/cm³) was adopted as an initial technique, using Tween 80 (0.2%) and decinormal sodium hydroxide as solutions for washing the samples. Ten tests were done to compare the variables, using counting in triplicate. The sieving of the material reduced significantly the recovery of eggs (p < 0.001) and the number of eggs recovered was higher when the sediment was resuspended (p < 0.05). After standardization, flotation solutions sodium chloride, zinc sulfate, sodium dichromate, magnesium sulfate, and sodium nitrate (d = 1.20g/cm³) were compared. The best results were obtained by using zinc sulfate solution. In conclusion, the chances of recovering T. canis eggs from samples using flotation solutions can be increased by washing of soil twice using distilled water, and resuspension of sediment. On the other hand, the sieving procedure can drastically reduce the number of eggs.
Resumo:
A chemical test previously described for the diagnosis of pregnancy was applied to the study of the excretion of gonadotropin in the urine during menstrual cycle. The chemical test is based on the selective adsorption by kaolim of the reducing substances biologically related to urinary gonadotropin. The active substance when acidified to pH 4.0 is adsorbed by the kolin and eluated with O.1N sodium hydroxide. The alkaline solution is treated by Somogyi's copper reagent and the excess not reduced is titrated by 0.005 N sodium thiosulfate. Gonadotropin is quantitatively addorbed by kaolin at pH 4.0 and eluated by alkaline solution as previously demonstrated by the A. (1). In the present paper the complete menstrual cycle was studied daily. It was observed that normally there are two distinct maxima of excretion. This study is based on 11 normal cycles (24-30 days) and 34 abnormal ones. Normal cycles showed a intramenstrual estrogens elimination from 200 to 260 mice units determinated by the Allen - Doisy full estrus smear test. The abnormal cycles belonging also to normal women showed much less estrogen excretion (14 to 25 mice units) Table II). In those cases with decreased estrogen excretion no fall in the curve after 14 th. day was observed. The A. suggest that the peaks of gonadotropin excretion is not related to the oculation but possibly due, the first one, to the follicle stimulating hormone and the second to the luteinizing hormone of hormone stimulating of the inerstitial tissue.
Resumo:
Knowledge of the soil physical properties, including the clay content, is of utmost importance for agriculture. The behavior of apparently similar soils can differ in intrinsic characteristics determined by different formation processes and nature of the parent material. The purpose of this study was to assess the efficacy of separate or combined pre-treatments, dispersion methods and chemical dispersant agents to determine clay in some soil classes, selected according to their mineralogy. Two Brazilian Oxisols, two Alfisols and one Mollisol with contrasting mineralogy were selected. Different treatments were applied: chemical substances as dispersants (lithium hydroxide, sodium hydroxide, and hexametaphosphate); pre-treatment with dithionite, ammonium oxalate, and hydrogen peroxide to eliminate organic matter; and coarse sand as abrasive and ultrasound, to test their mechanical action. The conclusion was drawn that different treatments must be applied to determine clay, in view of the soil mineralogy. Lithium hydroxide was not efficient to disperse low-CEC electropositive soils and very efficient in dispersing high-CEC electronegative soils. The use of coarse sand as an abrasive increased the clay content of all soils and in all treatments in which dispersion occurred, with or without the use of chemical dispersants. The efficiency of coarse sand is not the same for all soil classes.
Resumo:
This article describes the combination of low- and high-pressure flow systems for the determination of Magnesium, Calcium and Strontium by flame atomic absorption spectrometry (FAAS). In the low-pressure system a short C-18 RP column (length 0,5 cm) was utilized for the preconcentration/matrix separation step, xylenol orange was used as chelating agent and tetrabutylamonium acetate for ion pair formation. The hydraulic high pressure nebulization (HHPN) was used for sample transport and sample introduction in the high pressure system. The repeatabilities and detection limits for Mg, Ca and Sr were determined and compared with those obtained by pneumatic nebulization (PN). The results show that the detection limits obtained using the HHPN for Mg, Ca and Sr are between 1.5 to 2 times better than those obtained by PN when the signal transient was measured in area. The system presented a sampling frequency of 130 h-1 for direct determination of Mg, Ca or Sr in samples of saturated sodium chloride used in the production of chlorine and sodium hydroxide.
Resumo:
The preparation of gamma-LiAlO2 by coprecipitation and sol-gel synthesis was investigated. Ceramic powders obtained by coprecipitation synthesis were prepared from aqueous solutions of aluminum and lithium nitrates using sodium hydroxide as precipitant agent. By sol-gel synthesis, the ceramic powders were prepared from hydrolysis of aluminum isopropoxide. The materials obtained by two routes of synthesis were dried at 80ºC and calcined at 550, 750, 950 and 1150ºC. The characterization was done by X-ray diffraction, infrared spectroscopy, emission and absorption atomic spectrometry, helium picnometry, specific surface area (BET method) and scanning electronic microscopy. Mixtures of crystalline phases were obtained by coprecipitation synthesis: 80ºC- LiAl2(OH)7.2H2O + Al(OH)3; 550 and 750ºC- alpha-LiAlO2 + eta-Al2O3; 950 and 1150ºC- gamma-LiAlO2 + LiAl5O8. Chemical analysis showed molar ration Al/Li @ 3. Crystalline single-phases were obtained by sol-gel synthesis above 550ºC: 550ºC-alpha-LiAlO2; 750, 950 and 1150ºC-gamma-LiAlO2. These powders presented molar ration Al/Li @ 1. Thus, gamma-LiAlO2 crystalline phase was obtained at 750ºC by sol-gel synthesis while by coprecipitation synthesis, a mixture of crystalline phases was obtained. These results showed the superiority of the sol-gel synthesis for the preparation of pure gamma-LiAlO2.
Resumo:
A flow injection spectrophotometric procedure is proposed for the determination of paracetamol (acetaminophen) in pharmaceutical formulations. Powdered and liquid samples were previously dissolved/diluted in 0.05 mol L-1 hydrochloric acid solution and a volume of 250 µL was injected directly into a carrier stream of this same acid solution, flowing at 2.5 mL min-1. Paracetamol reacts with sodium hypochlorite forming N-acetyl-p-benzoquinoneimine which then reacts with sodium salicylate in sodium hydroxide solution yielding a blue indophenol dye which was measured at 640 nm in the pH range of 9.5-10.0. Paracetamol was determined in pharmaceutical products in the 1.0 to 100.0 mg L-1 (3.3x10-6 a 6.6x10-4 mol L-1) concentration range, with a detection limit of 0.5 mg L-1 (1.6x10-6 mol L-1). The recovery of this analyte in five samples ranged from 98.0 to 103.6 %. The analytical frequency was 80 determinations per hour and the RSDs were less than 1% for paracetamol concentrations of 25.0, 50.0 and 75.0 mg L-1 (n=10). A paired t-test showed that all results obtained for paracetamol in commercial formulations using the proposed flow injection procedure and a spectrophotometric batch procedure agree at the 95% confidence level.
Resumo:
UNS S31254 SS electrodes have been built to substitute platinum in conductimetric titrations. The electrodes were tested in both acid-basic titration (chloridric acid and sodium hydroxide) and precipitation titration (sodium chloride and argentum nitrate as titrant). The practical application was exemplified from conductimetric tritations of HF ¾ HNO3 mixtures used in metalurgical industry to passivate stainless steels. The results were compared with those obtained using commercial platinum electrodes. The equivalent volumes obtained were comparable within 3% experimental error. Its application depends on the nature of electrolyte. These results have shown that stainless steel, less expensive than platinum (about three order of magnitude), can substitute platinum electrodes in routine analyses and didactic laboratories.
Resumo:
A system for disposal and recovery of the main effluents and chemical waist from isotope separation plants and enriched compounds-15N and 34S production has been carried out at the Stable Isotope Laboratory (LIE) of the CENA/USP. Around four hundred thousand liters of effluents has been recovered yearly. Among the recovered chemical wastes, the more relevant are: ammonia; brome; ammonium and sodium sulfate; sodium hydroxide; sulfur dioxide; and hydrochloric acid. Chemical wastes containg recoverable heavy metals (Ag, Cr and Cu) and solvents (methanol, ethanol and acetone) are processed and recovered. Gaseous emissions, mainly H2S are used for recovery of heavy metals solutions. The minimization of the residues waters, as well the reduction of electric energy consume was established using a water deionization system. A cost/effect balance of the process is reported.
Resumo:
Procion Green HE-4BD is a reactive dye currently used in affinity purification, and commonly present as a contaminant in the final biological preparation. An assay method is described to determine trace amounts of the dye in the presence of human serum albumin(HSA) and leakage from agarose as affinity sorbent by cathodic stripping voltammetry. The proposed method is based on the reductive peak at -0.55V in B-R buffer pH 3 (E=0V and t= 240s), obtained when samples of HSA 2% (m/v) containing dye concentrations in sodium hydroxide pH 12 are submitted to a heating time of 330 min at 80 ºC. Linear calibration curves can be obtained for RG19 dye concentrations from 5x10-9 mol L-1 to 8 x10-8 mol L-1. The detection limit (3sigma) is 1x10-9 mol L-1.
Resumo:
This work presents two recycling processes for spent Li/MnO2 batteries. After removal of the solvent under vacuum the cathode + anode + electrolyte was submitted to one of the following procedures: (a) it was calcined (500 ºC, 5 h) and the calcined solid was submitted to solvent extraction with water in order to recover lithium salts. The residual solid was treated with sulfuric acid containing hydrogen peroxide. Manganese was recovered as sulfate; (b) the solid was treated with potassium hydrogeno sulfate (500 ºC, 5 h). The solid was dissolved in water and the resulting solution was added dropwise to sodium hydroxide. Manganese was recovered as dioxide. The residual solution was treated with potassium fluoride in order to precipitate lithium fluoride.
Resumo:
The "active mass" (cathode + anode + electrolyte) of spent Li-ion batteries was submitted to one of the following procedures: (a) it was calcined (500 ºC) and submitted to extraction with water to recover lithium salts. The residual solid was treated with sulfuric acid containing hydrogen peroxide. Cobalt was recovered as sulfate; (b) the "active mass" was treated with potassium hydrogen sulfate (500 ºC) and dissolved in water. Cobalt was precipitated together with copper after addition of sodium hydroxide. Lithium was partially recovered as lithium fluoride. Co-processing of other battery components (aluminum and copper foils) affected negatively the behavior of the recovery procedures. Previous segregation of battery components is essential for an efficient and economical processing of the "active mass".
Resumo:
The present paper focuses on improving chromium (III) uptake capacity of sugarcane bagasse through its chemical modification with citric acid and/or sodium hydroxide. The chemical modifications were confirmed by infrared spectroscopy, with an evident peak observed at 1730 cm-1, attributed to carbonyl groups. Equilibrium was reached after 24 h, and the kinetics followed the pseudo-second-order model. The highest chromium (III) maximum adsorption capacity (MAC) value was found when using sugarcane bagasse modified with sodium hydroxide and citric acid (58.00 mg g-1) giving a MAC value about three times greater (20.34 mg g-1) than for raw sugarcane bagasse.