371 resultados para Tunneled central catheter
Resumo:
Yeasts of the genus Candida have been recognized as important microorganisms responsible for nosocomial fungemia. Six blood-stream and two intravenous central catheter C. albicans strains were isolated from eight patients and studied by electrophoretic karyotyping of chromosomal DNA by pulsed-field gel electrophoresis. Seven chromosomal DNA profiles were identified. Two patients showed isolates with the same profile, suggesting nosocomial transmission. Karyotyping of C. albicans revealed an excellent discriminatory power among the isolates and may therefore be useful in the study of nosocomial candidemia.
Resumo:
The incidence of Candida bloodstream infection has increased over the past years. In the Center-West region of Brazil, data on candidemia are scarce. This paper reports a retrospective analysis of 96 cases of Candida bloodstream infection at a Brazilian tertiary-care teaching hospital in the state of Mato Grosso do Sul, from January 1998 to December 2006. Demographic, clinical and laboratory data were collected from medical records and from the hospital's laboratory database. Patients' ages ranged from three days to 92 years, with 53 (55.2%) adults and 43 (44.8%) children. Of the latter, 25 (58.1%) were newborns. The risk conditions most often found were: long period of hospitalization, utilization of venous central catheter, and previous use of antibiotics. Fifty-eight (60.4%) patients died during the hospitalization period and eight (13.7%) of them died 30 days after the diagnosis of candidemia. Candida albicans (45.8%) was the most prevalent species, followed by C. parapsilosis (34.4%), C. tropicalis (14.6%) and C. glabrata (5.2%). This is the first report of Candida bloodstream infection in the state of Mato Grosso do Sul and it highlights the importance of considering the possibility of invasive Candida infection in patients exposed to risk factors, particularly among neonates and the elderly.
Resumo:
Complications from central venous catheterization include infectious conditions, pneumothorax, hemothorax and venous thrombosis. Pericardial effusion with cardiac tamponade hardly occurs, and in infants is generally caused by umbilical catheterization. The authors describe the case of cardiac tamponade occurred in an infant during chest computed tomography with contrast infusion through a central venous catheter inserted into the right internal jugular vein.
Resumo:
Mycobacterium tuberculosis was isolated from a central venous catheter in a non-immunosuppressed patient with systemic tuberculosis. This case report represents a very uncommon form of isolation of Mycobacterium tuberculosis. A total improvement was obtained after treatment.
Resumo:
INTRODUCTION: Catheter-associated bloodstream infection (CA-BSI) is the most common nosocomial infection in neonatal intensive care units. There is evidence that care bundles to reduce CA-BSI are effective in the adult literature. The aim of this study was to reduce CA-BSI in a Brazilian neonatal intensive care unit by means of a care bundle including few strategies or procedures of prevention and control of these infections. METHODS: An intervention designed to reduce CA-BSI with five evidence-based procedures was conducted. RESULTS: A total of sixty-seven (26.7%) CA-BSIs were observed. There were 46 (32%) episodes of culture-proven sepsis in group preintervention (24.1 per 1,000 catheter days [CVC days]). Neonates in the group after implementation of the intervention had 21 (19.6%) episodes of CA-BSI (14.9 per 1,000 CVC days). The incidence of CA-BSI decreased significantly after the intervention from the group preintervention and postintervention (32% to 19.6%, 24.1 per 1,000 CVC days to 14.9 per 1,000 CVC days, p=0.04). In the multiple logistic regression analysis, the use of more than 3 antibiotics and length of stay >8 days were independent risk factors for BSI. CONCLUSIONS: A stepwise introduction of evidence-based intervention and intensive and continuous education of all healthcare workers are effective in reducing CA-BSI.
Resumo:
Introduction Vascular access in patients undergoing hemodialysis is considered a critical determinant of bloodstream infection (BSI) and is associated with high morbidity and mortality. The purpose of this study was to investigate the occurrence of BSI in patients with end-stage renal disease using central venous catheters for hemodialysis. Methods A cohort study was conducted in a public teaching hospital in central-western Brazil from April 2010 to December 2011. For every patient, we noted the presence of hyperemia/exudation upon catheter insertion, as well as fever, shivering, and chills during hemodialysis. Results Fifty-nine patients were evaluated. Thirty-five (59.3%) patients started dialysis due to urgency, 37 (62.7%) had BSI, and 12 (20%) died. Hyperemia at the catheter insertion site (64.9%) was a significant clinical manifestation in patients with BSI. Statistical analysis revealed 1.7 times more cases of BSI in patients with hypoalbuminemia compared with patients with normal albumin levels. The principal infective agents identified in blood cultures and catheter-tip cultures were Staphylococcus species (24 cases), non-fermentative Gram-negative bacilli (7 cases of Stenotrophomonas maltophilia and 5 cases of Chryseobacterium indologenes), and Candida species (6). Among the Staphylococci identified, 77.7% were methicillin-resistant, coagulase-negative Staphylococci. Of the bacteria isolated, the most resistant were Chryseobacterium indologenes and Acinetobacter baumannii. Conclusions Blood culture was demonstrated to be an important diagnostic test and identified over 50% of positive BSI cases. The high frequency of BSI and the isolation of multiresistant bacteria were disturbing findings. Staphylococcus aureus was the most frequently isolated microorganism, although Gram-negative bacteria predominated overall. These results highlight the importance of infection prevention and control measures in dialysis units.
Resumo:
PURPOSE: Infection is the leading complication of long-term central venous catheters, and its incidence may vary according to catheter type. The objective of this study was to compare the frequency and probability of infection between two types of long-term intravenous devices. METHODS: Retrospective study in 96 onco-hematology patients with partially implanted catheters (n = 55) or completely implanted ones (n = 42). Demographic data and catheter care were similar in both groups. Infection incidence and infection-free survival were used for the comparison of the two devices. RESULTS: In a median follow-up time of 210 days, the catheter-related infection incidence was 0.2102/100 catheter-days for the partially implanted devices and 0.0045/100 catheter-days for the completely implanted devices; the infection incidence rate was 46.7 (CI 95% = 6.2 to 348.8). The 1-year first infection-free survival ratio was 45% versus 97%, and the 1-year removal due to infection-free survival ratio was 42% versus 97% for partially and totally implanted catheters, respectively (P <.001 for both comparisons). CONCLUSION: In the present study, the infection risk was lower in completely implanted devices than in partially implanted ones.
Resumo:
Abstract OBJECTIVE Determining which is the most effective solution (heparin flush compared to 0.9% saline flush) for reducing the risk of occlusions in central venous catheters (CVC) in adults. METHOD The systematic review followed the principles proposed by the Cochrane Handbook; critical analysis, extraction and synthesis of data were performed by two independent researchers; statistical analysis was performed using the RevMan program 5.2.8. RESULTS Eight randomized controlled trials and one cohort study were included and the results of the meta-analysis showed no difference (RR=0.68, 95% CI=0.41-1.10; p=0.12). Analysis by subgroups showed that there was no difference in fully deployed CVC (RR=1.09, CI 95%=0.53-2.22;p=0.82); Multi-Lumen CVC showed beneficial effects in the heparin group (RR=0.53, CI 95%=0.29-0.95; p=0.03); in Double-Lumen CVC for hemodialysis (RR=1.18, CI 95%=0.08-17.82;p=0.90) and Peripherally inserted CVC (RR=0.14, CI 95%=0.01-2.60; p=0.19) also showed no difference. CONCLUSION Saline solution is sufficient for maintaining patency of the central venous catheter, preventing the risks associated with heparin administration.
Resumo:
O objetivo deste trabalho é a apresentação de um caso de um indivíduo de 9 anos de idade, do sexo masculino, com queixa de distúrbio de aprendizagem, para o qual a efetividade da fonoterapia pôde ser avaliada através de testes objetivos e comportamentais, compreendendo audiometria tonal, imitanciometria, potenciais auditivos evocados de tronco encefálico, P300 e Avaliação do Processamento Auditivo Central. Foram encontrados resultados normais nos exames otorrinolaringológico e audiológico. O P300 foi realizado mostrando tempo de latência aumentada. A avaliação do Processamento Auditivo Central revelou uma desordem em grau severo, caracterizada por alterações nos processos de codificação, organização e memória, assim como dificuldade significativa para atenção seletiva e fechamento auditivo. Foi diagnosticado Desordem do Processamento Auditivo Central, sendo que o indivíduo foi encaminhado para acompanhamento fonoaudiológico com o objetivo de desenvolvimento das habilidades auditivas alteradas. Após um período de 4 meses de fonoterapia, repetidos os exames acima descritos, observou-se melhora nas latências do P300, a desordem permaneceu em grau moderado, com prejuízo mais significativo no processo de organização e não apresentou dificuldade para o fechamento auditivo. Podemos concluir com este estudo a efetividade da terapia fonoaudiológica para o desenvolvimento das habilidades auditivas, podendo ser verificada através da avaliação objetiva e comportamental.
Resumo:
A vertigem é um sintoma responsável por um grande número de visitas aos consultórios de médicos de diversas especialidades. Dessa forma, um conhecimento apropriado sobre sua etiologia e fisiopatologia possíveis é extremamente importante. Apresentamos um caso clínico que ilustra o conjunto de possibilidades etiológicas para este sintoma e a importância da completa avaliação do paciente, sempre valorizando suas queixas.
Resumo:
O Mismatch Negativity (MMN) é um potencial evocado auditivo de longa latência que fornece uma medida objetiva das habilidades de discriminação e memória sensorial auditiva. Assim, pode ser utilizado como uma avaliação eletrofisiológica do processamento auditivo (central). OBJETIVO: Estudar o MMN em pacientes com Distúrbios do Processamento Auditivo (Central) - DPA(C). FORMA DO ESTUDO: Clínico prospectivo. MATERIAL E MÉTODO: Foram avaliados oito sujeitos com DPA(C), na faixa etária de nove a 14 anos, bem como um grupo controle. O MMN foi eliciado para estímulos tonais (tone bursts) diferindo quanto à freqüência (MMNf - estímulo padrão: 750Hz e estímulo diferente: 1000Hz ), bem como quanto à duração (MMNd - estímulo padrão: 100 ms e estímulo diferente: 50 ms; na freqüência de 1000Hz). RESULTADOS: A presença do MMNf e do MMNd foi comprovada estatisticamente em ambos os grupos estudados. Não foram constatadas diferenças significantes estatisticamente entre os valores de latência e de amplitude do MMNf e do MMNd obtidos nos dois grupos. Também não foram verificadas diferenças significantes estatisticamente entre o MMNf e o MMNd em nenhum dos grupos estudados. CONCLUSÃO: Os sujeitos com DPA(C) avaliados não apresentaram alterações no MMNf, nem no MMNd.
Resumo:
O artigo analisa alguns aspectos da percepção brasileira sobre o conflito regional imperante na América Central, entre 1979 e 1996. Na conclusão sugere-se que essa política fundamentou-se no que aqui se chama de a "tese brasileira" sobre a origem, a evolução e os possíveis mecanismos de resolução para o conflito regional.
Resumo:
Coffee cultivation via central-pivot fertigation can lead to fertilizer losses by soil profile internal drainage when water application is excessive and soils have low water retention and cation adsorption capacities. This study analyses the deep water losses from the top 1 m sandy soil layer of east Bahia, Brazil, cultivated with coffee at a high technology level (central-pivot fertigation), using above normal N fertilizer rates. The deep drainage (Q) estimation is made through the application of a climatologic water balance (CWB) program having as input direct measures of irrigation and rainfall, climatological data from weather stations, and measured soil water retention characteristics. The aim of the study is to contribute to the understanding of the hydric regime of coffee crops managed by central-pivot irrigation, analyzing three scenarios (Sc): i) rainfall only, ii) rainfall and irrigation full year, and iii) rainfall and irrigation dry season only. Annual Q values for the 2008/2009 agricultural year were: Sc i = 811.5 mm; Sc ii = 1010.5 mm; and Sc iii = 873.1 mm, so that the irrigation interruption in the wet season reduced Q by 15.7%, without the appearance of water deficit periods. Results show that the use of the CWB program is a convenient tool for the evaluation of Q under the cited conditions.
Resumo:
Nitrogen has a complex dynamics in the soil-plant-atmosphere system. N fertilizers are subject to chemical and microbial transformations in soils that can result in significant losses. Considering the cost of fertilizers, the adoption of good management practices like fertigation could improve the N use efficiency by crops. Water balances (WB) were applied to evaluate fertilizer N leaching using 15N labeled urea in west Bahia, Brazil. Three scenarios (2008/2009) were established: i) rainfall + irrigation the full year, ii) rainfall only; and iii) rainfall + irrigation only in the dry season. The water excess was considered equal to the deep drainage for the very flat area (runoff = 0) with a water table located several meters below soil surface (capillary rise = 0). The control volume for water balance calculations was the 0 - 1 m soil layer, considering that it involves the active root system. The water drained below 1 m was used to estimate fertilizer N leaching losses. WB calculations used the mathematic model of Penman-Monteith for evapotranspiration, considering the crop coefficient equal to unity. The high N application rate associated to the high rainfall plus irrigation was found to be the main cause for leaching, which values were 14.7 and 104.5 kg ha-1 for the rates 400 and 800 kg ha-1 of N, corresponding to 3.7 and 13.1 % of the applied fertilizer, respectively.
Resumo:
Light and soil water availability may limit carbon uptake of trees in tropical rainforests. The objective of this work was to determine how photosynthetic traits of juvenile trees respond to variations in rainfall seasonality, leaf nutrient content, and opening of the forest canopy. The correlation between leaf nutrient content and annual growth rate of saplings was also assessed. In a terra firme rainforest of the central Amazon, leaf nutrient content and gas exchange parameters were measured in five sapling tree species in the dry and rainy season of 2008. Sapling growth was measured in 2008 and 2009. Rainfall seasonality led to variations in soil water content, but it did not affect leaf gas exchange parameters. Subtle changes in the canopy opening affected CO2 saturated photosynthesis (A pot, p = 0.04). Although A pot was affected by leaf nutrient content (as follows: P > Mg > Ca > N > K), the relative growth rate of saplings correlated solely with leaf P content (r = 0.52, p = 0.003). At present, reduction in soil water content during the dry season does not seem to be strong enough to cause any effect on photosynthesis of saplings in central Amazonia. This study shows that leaf P content is positively correlated with sapling growth in the central Amazon. Therefore, the positive effect of atmospheric CO2 fertilization on long-term tree growth will depend on the ability of trees to absorb additional amount of P