74 resultados para Pressure-indicating sensor film


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the resistance of Aedes aegypti to temephos Fersol 1G (temephos 1% w/w) associated with the adaptive disadvantage of insect populations in the absence of selection pressure. METHODS A diagnostic dose of 0.28 mg a.i./L and doses between 0.28 mg a.i./L and 1.40 mg a.i./L were used. Vector populations collected between 2007 and 2008 in the city of Campina Grande, state of Paraíba, were evaluated. To evaluate competition in the absence of selection pressure, insect populations with initial frequencies of 20.0%, 40.0%, 60.0%, and 80.0% resistant individuals were produced and subjected to the diagnostic dose for two months. Evaluation of the development of aquatic and adult stages allowed comparison of the life cycles in susceptible and resistant populations and construction of fertility life tables. RESULTS No mortality was observed in Ae. aegypti populations subjected to the diagnostic dose of 0.28 mg a.i./L. The decreased mortality observed in populations containing 20.0%, 40.0%, 60.0%, and 80.0% resistant insects indicates that temephos resistance is unstable in the absence of selection pressure. A comparison of the life cycles indicated differences in the duration and viability of the larval phase, but no differences were observed in embryo development, sex ratio, adult longevity, and number of eggs per female. CONCLUSIONS The fertility life table results indicated that some populations had reproductive disadvantages compared with the susceptible population in the absence of selection pressure, indicating the presence of a fitness cost in populations resistant to temephos.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In this communication we describe the application of a conductive polymer gas sensor as an air pressure sensor. The device consists of a thin doped poly(4'-hexyloxy-2,5-biphenylene ethylene) (PHBPE) film deposited on an interdigitated metallic electrode. The sensor is cheap, easy to fabricate, lasts for several months, and is suitable for measuring air pressures in the range between 100 and 700 mmHg.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT The efficiency of nitrogen fertilizer in corn is usually low, negatively affecting plant nutrition, the economic return, and the environment. In this context, a variable rate of nitrogen, prescribed by crop sensors, has been proposed as an alternative to the uniform rate of nitrogen traditionally used by farmers. This study tested the hypothesis that variable rate of nitrogen, prescribed by optical sensor, increases the nitrogen use efficiency and grain yield as compared to uniform rate of nitrogen. The following treatments were evaluated: 0; 70; 140; and 210 kg ha-1 under uniform rate of nitrogen, and 140 kg ha -1 under variable rate of nitrogen. The nitrogen source was urea applied on the soil surface using a distributor equipped with the crop sensor. In this study, the grain yield ranged from 10.2 to 15.5 Mg ha-1, with linear response to nitrogen rates. The variable rate of nitrogen increased by 11.8 and 32.6% the nitrogen uptake and nitrogen use efficiency, respectively, compared to the uniform rate of nitrogen. However, no significant increase in grain yield was observed, indicating that the major benefit of the variable rate of nitrogen was reducing the risk of environmental impact of fertilizer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Persons in palliative care develop pressure ulcers (PU) as death approaches, but the extent of the problem is still unknown. The objectives were to identify the prevalence of pressure ulcers in people with cancer in palliative home care, compare the socio-demographic and clinical profile of patients with and without pressure ulcers, and analyze the characteristics of the ulcers. This descriptive, cross-sectional study included 64 people with advanced cancer in palliative home care. Twelve of them (18.8%) had PU, of whom 75.0% were men. The participants had one to three PU, amounting to 19 lesions, 89.4% of those developed at home and 47.4% at stage 3. The presence of PU was higher among those who had a history of previous wound. PU consisted of a significant event occurring in the studied population, indicating that preventive measures should be included in the home palliative care health team.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Variable-rate nitrogen fertilization (VRF) based on optical spectrometry sensors of crops is a technological innovation capable of improving the nutrient use efficiency (NUE) and mitigate environmental impacts. However, studies addressing fertilization based on crop sensors are still scarce in Brazilian agriculture. This study aims to evaluate the efficiency of an optical crop sensor to assess the nutritional status of corn and compare VRF with the standard strategy of traditional single-rate N fertilization (TSF) used by farmers. With this purpose, three experiments were conducted at different locations in Southern Brazil, in the growing seasons 2008/09 and 2010/11. The following crop properties were evaluated: above-ground dry matter production, nitrogen (N) content, N uptake, relative chlorophyll content (SPAD) reading, and a vegetation index measured by the optical sensor N-Sensor® ALS. The plants were evaluated in the stages V4, V6, V8, V10, V12 and at corn flowering. The experiments had a completely randomized design at three different sites that were analyzed separately. The vegetation index was directly related to above-ground dry matter production (R² = 0.91; p<0.0001), total N uptake (R² = 0.87; p<0.0001) and SPAD reading (R² = 0.63; p<0.0001) and inversely related to plant N content (R² = 0.53; p<0.0001). The efficiency of VRF for plant nutrition was influenced by the specific climatic conditions of each site. Therefore, the efficiency of the VRF strategy was similar to that of the standard farmer fertilizer strategy at sites 1 and 2. However, at site 3 where the climatic conditions were favorable for corn growth, the use of optical sensors to determine VRF resulted in a 12 % increase in N plant uptake in relation to the standard fertilization, indicating the potential of this technology to improve NUE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A piezoelectric detector based on a commercial quartz crystal of 3.57MHz is shown. A PTFE cell attached to the GC-column outlet holds the polymer-coated crystal, whose terminals were removed. Two TTL oscillators (reference and sensor) are used and the beating of their frequencies is monitored through a home-made counter card inserted in a microcomputer. The original thermal conductivity detector was also interfaced, but through a 12-bit analog-to-digital converter. In spite of the well-known fact that QCM has low sensitivity at high temperatures, results show significant peak deformation for low temperatures. In addition, the phenomenon is also dependent on the chemical composition of the absorbent film besides instantaneous partial pressure and chemical composition of the analyte.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The binding of [Ru(PAN)(PPh3)2(ISN)]Cl (PAN = 1-(2'-Pyridylazo)-2-naphtholate) to bovine serum albumin (BSA) was investigated by spectroscopic techniques. According to analysis of the results from the Stern-Volmer equation, the ruthenium complex is able to quench the fluorescence intensity of BSA via a dynamic mechanism. The thermodynamic parameters were calculated (ΔH = 30.3 kJ mol-1; ΔS = 195.4 J mol-1 K-1), indicating that hydrophobic force is the main interaction driving force. The site marker competitive experiments revealed that the binding site of ruthenium complex was in the sub-domain IIA of BSA. FTO glass with a film of BSA-[Ru(PAN)(PPh3)2(ISN)]Cl was used as an ascorbic acid sensor. The linear range of the modified electrode was between 1 and 8 × 10-6 mol L-1.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Crude brain homogenates of terminally diseased hamsters infected with the 263 K strain of scrapie (PrP Sc) were heated and/or pressurized at 800 MPa at 60ºC for different times (a few seconds or 5, 30, 120 min) in phosphate-buffered saline (PBS) of different pH and concentration. Prion proteins were analyzed on immunoblots for their proteinase K (PK) resistance, and in hamster bioassays for their infectivity. Samples pressurized under initially neutral conditions and containing native PrP Sc were negative on immunoblots after PK treatment, and a 6-7 log reduction of infectious units per gram was found when the samples were pressurized in PBS of pH 7.4 for 2 h. A pressure-induced change in the protein conformation of native PrP Sc may lead to less PK resistant and less infectious prions. However, opposite results were obtained after pressurizing native infectious prions at slightly acidic pH and in PBS of higher concentration. In this case an extensive fraction of native PrP Sc remained PK resistant after pressure treatment, indicating a protective effect possibly due to induced aggregation of prion proteins in such buffers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pressure-driven and temperature-driven transitions of two thermoresponsive polymers, poly(N-isopropylacrylamide) (pNIPAM) and poly(N-vinylisobutyramide) (pNVIBA)), in both a soluble linear polymer form and a cross-linked hydro-gel form, were examined by a dynamic light-scattering method and direct microscopic observation, respectively. Their behavior was compared with that of protein systems. Changes in some characteristic parameters in the time-intensity correlation functions of dynamic light-scattering measurement of aqueous solutions of pNIPAM at various pressures and temperatures showed no essential differences during temperature and pressure scanning and, as a whole, the motions of polymers in aqueous solutions were similar in two types of transitions until chain shrinkage occurred. The gels (cross-linked polymer gels) prepared from the thermoresponsive polymers also showed similar volume transitions responding to the pressure and temperature increase. In temperature transitions, however, gels showed drastic volume shrinkage with loss of transparency, while pressure-induced transition showed a slow recovery of transparency while keeping the size, after first transient drastic volume shrinkage with loss of transparency. At a temperature slightly higher than the transition under atmospheric temperature, so-called reentry of the volume change and recovery of the transparency were observed during the pressure-increasing process, which implies much smaller aggregation or non-aggregated collapsed polymer chains in the gel at higher pressures, indicating a certain mechanistic difference of the dehydration processes induced by temperature and pressure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of high hydrostatic pressure (150, 250, 350, 450, and 550 MPa), applied for 5 minutes, on antioxidant capacity, total phenolic content, color, firmness, rehydration ratio, and water holding capacity of aloe vera gel stored for 60 days at 4 °C. The analyzed properties of the pressurized gel showed significant changes after the storage period. The highest value of total phenolic content was found at 550 MPa. However, a decrease in the antioxidant capacity was observed for all pressurized gel samples when compared to the control sample (p < 0.05). The smallest changes in product color were observed at pressure levels between 150 and 250 MP. The application of high hydrostatic pressure resulted in lower gel firmness, and the lowest value was found at 150 MPa (p < 0.05). On the other hand, the untreated sample showed a greater decrease in firmness, indicating that high pressure processing preserves this property. The application of high hydrostatic pressure exhibited modifications in the food matrix, which were evaluated in terms of rehydration ratio and water holding capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate and establish the mean values of IOP in healthy adult sheep using an applanation tonometer. Information on age, sex, and breed was obtained for all animals included in this study. Twenty five healthy sheep (Ovis aries), of the same breed (Texel), male or female, with three years of age, received an ophthalmic examination in both eyes, including pupillary reflexes, Schirmer tear test, slit lamp biomicroscopy, and fluorescein staining. For all ophthalmic testing, animals were gently physically restrained, with no pressure in the jugular area and the eyelids were carefully open. IOP was measured by applanation tonometry (Tonopen XL). The same examiner performed the tonometry; measurements were taken three times for each eye, and their average was recorded as the IOP of the animal. Statistical analysis was performed using paired t-test and values of P < 0.05 were considered significant. The mean intraocular pressure in the whole group of 50 eyes was of 16.36 +/- 2.19 mm Hg. The mean (SD) IOP in the right eye was of 15.96 +/- 2.02 mm Hg, while the mean (SD) IOP in the left eye was of 16.76 +/- 2.32 mm Hg. Significant differences in IOP were not found between right and left eyes. The applanation tonometer was adequate for measuring the intraocular pressure in sheep. Reference data will assist in diagnosing testing for ophthalmic disease in sheep, as¹ well as promote further studies in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A evapotranspiração define a perda total de água do sistema solo-planta para a atmosfera. Nas áreas agrícolas, particularmente onde se pratica algum tipo de irrigação, a determinação da evapotranspiração, por via de sensoriamento remoto, vem ganhando cada vez mais importância, pois possibilita identificar a eficiência com que a água tem sido utilizada. Nesse contexto, este trabalho tem o objetivo de determinar a evapotranspiração real diária (ETr diária), com a utilização de produtos do sensor MODIS, nas sub-bacias do Ribeirão Entre Ribeiros e Rio Preto, que ficam entre os Estados de Goiás e Minas Gerais. O SEBAL (Surface Energy Balance Algorithm for Land) foi utilizado para a obtenção da ETr diária em quatro dias diferentes, no período de julho a outubro de 2007. Os resultados encontrados foram compatíveis com os citados em outras literaturas e a comparação entre a evapotranspiração, obtida pelo SEBAL, e a evapotranspiração da cultura (ETc) demonstraram que esse algoritmo pode ser utilizado como boa opção para determinar, com a utilização de produtos do sensor MODIS, a evapotranspiração diária nas condições das sub-bacias do ribeirão Entre Ribeiros e rio Preto.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

^len^lpt^aOBJETIVO: Descrever a prevalência de pressão arterial limítrofe (PAL) e hipertensão (HT) entre adultos jovens e avaliar a associação entre tamanho ao nascer e PAL/HT. MÉTODOS: Dados foram coletados do primeiro estudo brasileiro de coorte de nascimentos em Ribeirão Preto (sudeste do Brasil), iniciado em 1978/79. De 6.827 recém-nascidos de parto único hospitalar, 2.060 foram avaliados aos 23/25 anos. Foram realizadas coleta de sangue, avaliação antropométrica e obtidas informações sobre ocupação, escolaridade, hábitos de vida e doenças crônicas. Pressão arterial (PA) foi classificada em: 1) PAL: PA sistólica (PAS) ≥ 130 e < 140 mm Hg e/ou PA diastólica (PAD) ≥ 85 e < 90 mmHg; 2) HT: PAS ≥ 140 e/ou PAD ≥ 90 mm Hg. Foi aplicado modelo de regressão logística politômica. RESULTADOS: A prevalência de PAL foi de 13,5% (homens 23,2%) e a de HT, 9,5% (homens 17,7%). PAL foi independentemente associada com sexo masculino (RR 8,84; IC95%: 6,09;12,82), comprimento ao nascer ≥ 50 cm (RR 1,97; 1,04; 3,73), índice de massa corporal (IMC) ≥ 30 kg/m² (RR 3,23; 2,02; 5,15) e circunferência de cintura alterada (RR 1,61; 1,13;2,29), enquanto HT associou-se com sexo masculino (RR 15,18; 8,92;25,81), IMC ≥ 30 kg/m² (RR 3,68; 2,23;6,06), circunferência de cintura alterada (RR 2,68; 1,77;4,05) e glicemia elevada (RR 2,55; 1,27;5,10), mas não com comprimento ao nascer. CONCLUSÕES: As prevalências de PAL e HT entre os adultos jovens dessa coorte foram maiores em homens que em mulheres. Maior comprimento ao nascer foi associado com PAL, mas não com HT, enquanto peso ao nascer não foi associado com PAL ou HT. Fatores de risco do adulto explicaram a maioria dos aumentos de PAL ou HT.^les^aOBJETIVO: Describir la prevalencia de presión arterial limítrofe (PAL) e hipertensión (HT) entre adultos jóvenes y evaluar la asociación entre tamaño al nacer y PAL/HT. MÉTODOS: : Los datos fueron colectados en el primer estudio de cohorte de nacimientos brasileño en Ribeirao Preto (sureste de Brasil), iniciado en 1978/79. De 6.827 recién nacidos de parto único hospitalario, 2.060 fueron evaluados a los 23/25 años. Se realizaron colecta de sangre, evaluación antropométrica y obtenidas informaciones sobre ocupación, escolaridad, hábitos de vida y enfermedades crónicas. Presión arterial (PA) fue clasificada en: 1) PAL: PA sistólica (PAS) ≥ 130 y < 140 mm Hg y/o PA diastólica (PAD) ≥ 85 y < 90 mm Hg; 2) HT: PAS ≥ 140 y/o PAD ≥ 90 mm Hg. Se aplicó modelo de regresión logística politómica. RESULTADOS: La prevalencia de PAL fue de 13,5% (hombres 23,2%) y la de HT, 9,5% (hombres 17,7%). PAL fue independientemente asociada con sexo masculino (Riesgo Relativo - RR) 8,84; 95%IC: 6,09;12,82), estatura al nacer ≥ 50 cm (RR 1,97; 1,04; 3,73), índice de masa corporal (IMC) ≥ 30 kg/m2 (RR 3,23; 2,02; 5,15) y circunferencia de cintura alterada (RR 1,61; 1,13;2,29), mientras el HT se asoció con sexo masculino (RR 15,18; 8,92;25,81), IMC ≥ 30 kg/m2 (RR 3,68; 2,23;6,06), circunferencia de cintura alterada (RR 2,68; 1,77;4,05) y glicemia elevada (RR 2,55; 1,27;5,10), pero no con estatura al nacer. CONCLUSIONES: Las prevalencias de PAL y HT entre los adultos jóvenes de la cohorte fueron mayores en hombres que en mujeres. Mayor estatura al nacer fue asociado con PAL, pero no con HT, mientras que el peso al nacer no estuvo asociado con PAL o HT. Factores de riesgo de adulto explicaron la mayoría de los aumentos de PAL o HT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to determine the prevalence of ocular lesions in HTLV-1 infected patients in Salvador Bahia, a transversal study was conducted on 140 HTLV-1 infected patients (90 asymptomatic and 50 tropical spastic paraparesis/HTLV-1-associated myelopathy) between June 2004 and November 2005. The ophthalmological examination included visual acuity measurement, ocular motility, biomicroscopy of the anterior and posterior chambers, intraocular pressure and evaluation of lachrymal secretion. Observation verified 4 (2.8%) out of 140 patients with uveitis (two patients had intermediate uveitis and two had pan-uveitis) and 39 (36.4%) out of 107 patients with keratoconjunctivitis sicca. The prevalence of Keratoconjunctivitis sicca was significantly higher among the TSP/HAM patients (OR age adjusted=3.64; 95%CI 1.59-8.32). Uveitis and corneal opacities were also important findings, indicating the strong need for periodic ophthalmological follow-up in all HTLV-1 subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Previous studies describe an imbalance of the autonomic nervous system in Chagas' disease causing increased sympathetic activity, which could influence the genesis of hypertension. However, patients undergoing regular physical exercise could counteract this condition, considering that exercise causes physiological responses through autonomic and hemodynamic changes that positively affect the cardiovascular system. This study aimed to evaluate the effects of an exercise program on blood pressure in hypertensive patients with chronic Chagas' heart disease. METHODS: We recruited 17 patients to a 24-week regular exercise program and used ambulatory blood pressure monitoring before and after training. We determined the differences in the systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean blood pressure (MBP) from the beginning to the end of the study. RESULTS: The blood pressures were evaluated in general and during periods of wakefulness and sleep, respectively: SBP (p = 0.34; 0.23; 0.85), DBP (p = 0.46; 0.44; 0.94) and MBP (p = 0.41; 0.30; 0.97). CONCLUSIONS: There was no statistically significant change in blood pressure after the 24-week exercise program; however, we concluded that physical training is safe for patients with chronic Chagas' disease, with no incidence of increase in blood pressure.