175 resultados para Neonatal Care


Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE Identify resources that support learning mediated by technology in the field of neonatal nursing. METHOD Systematic review with searches conducted in MEDLINE, LILACS and SciELO. Titles and abstracts were independently evaluated by two experts. RESULTS Of the 2,051 references, 203 full-text articles were analyzed, resulting in the inclusion of nine studies on semiotics and semiology, cardiopulmonary resuscitation, general aspects of neonatal care, diagnostic reasoning and assessment of pain. Only two articles addressed the development of educational strategies and seven papers described the assessment of these strategies by experts and/or users. CONCLUSION Distance education is an important resource for education, and its improvement and updating, and it particularly adds advantages for neonatal nursing by approximating teaching and real-life situations and by minimizing the exposure of newborns for teaching purposes. The lack of educational initiatives mediated by technology suggests the need for the development, evaluation and dissemination of educational resources focused on nursing care of newborns and their families.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To determine changes in the incidence of vaginal deliveries, cesarean sections, and forceps deliveries and their potential association with fetal, early neonatal, and perinatal mortality rates over time. METHODS: A retrospective study was carried out and the occurrence of deliveries supervised by university services between January 1991 and December 2000 was determined. Data regarding fetal, early neonatal, and perinatal deaths were assessed using obstetric and pediatric records and autopsy reports. RESULTS: Of a total of 33,360 deliveries, the incidence of vaginal deliveries, cesarean sections, and forceps deliveries was relatively steady (around 60, 30, and 10%, respectively) while, at the same time, there was a marked reduction in fetal mortality (from 33.3 to 13.0‰), early neonatal mortality (from 30.6 to 9.0‰), and perinatal mortality (from 56.4 to 19.3‰). CONCLUSIONS: The marked reduction in perinatal mortality rates seen during the study period without an increase in cesarean sections indicates that the decrease in perinatal mortality was not impacted by cesarean section rates. The plausible hypothesis seems to be that the reduction in perinatal mortality of deliveries performed under the supervision of university services was more likely to be associated with better neonatal care rather than the mode of delivery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Enterococci are Gram-positive cocci saprophyte of the human gastrointestinal tract, diners who act as opportunistic pathogens. They can cause infections in patients hospitalized for a long time or who have received multiple antibiotic therapy. Enterococcus faecalis and Enterococcus faecium are the most common species in human infections. To evaluate the possibility of rapid detection of these species and their occurrence in the blood of newborns with suspected nosocomial infection, blood samples were collected from 50 newborns with late infections, admitted to the Neonatal Care Unit of the University Hospital Federal de Mato Grosso do Sul (UFMS-HU), from September 2010 to January 2011. The samples were subjected to conventional PCR and real time PCR (qPCR) to search for Enterococcus faecium and Enterococcus faecalis, respectively. The PCR results were compared with respective blood cultures from 40 patients. No blood cultures were positive for Enterococci, however, eight blood samples were identified as genomic DNA of Enterococcus faecium by qPCR and 22 blood samples were detected as genomic DNA of Enterococcus faecalis by conventional PCR. These findings are important because of the clinical severity of the evaluated patients who were found positive by conventional PCR and not through routine microbiological methods.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The assessment of fluid volume in neonates by a noninvasive, inexpensive, and fast method can contribute significantly to increase the quality of neonatal care. The objective of the present study was to calibrate an acquisition system and software to estimate the bioelectrical impedance parameters obtained by a method of bioelectrical impedance spectroscopy based on step response and to develop specific equations for the neonatal population to determine body fluid compartments. Bioelectric impedance measurements were performed by a laboratory homemade instrument. The volumes were estimated in a clinical study on 30 full-term neonates at four different times during the first month of life. During the first 24 hours of life the total body water, extracellular water and intracellular water were 2.09 ± 0.25, 1.20 ± 0.19, and 0.90 ± 0.25 liters, respectively. By the 48th hour they were 1.87 ± 0.27, 1.08 ± 0.17, and 0.79 ± 0.21 liters, respectively. On the 10th day they were 2.02 ± 0.25, 1.29 ± 0.21, and 0.72 ± 0.14 liters, respectively, and after 1 month they were 2.34 ± 0.27, 1.62 ± 0.20, and 0.72 ± 0.13 liters, respectively. The behavior of the estimated volume was correlated with neonatal body weight changes, leading to a better interpretation of such changes. In conclusion, this study indicates the feasibility of bioelectrical impedance spectroscopy as a method to help fluid administration in intensive care neonatal units, and also contribute to the development of new equations to estimate neonatal body fluid contents.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To identify potential prognostic factors for neonatal mortality among newborns referred to intensive care units. METHODS: A live-birth cohort study was carried out in Goiânia, Central Brazil, from November 1999 to October 2000. Linked birth and infant death certificates were used to ascertain the cohort of live born infants. An additional active surveillance system of neonatal-based mortality was implemented. Exposure variables were collected from birth and death certificates. The outcome was survivors (n=713) and deaths (n=162) in all intensive care units in the study period. Cox's proportional hazards model was applied and a Receiver Operating Characteristic curve was used to compare the performance of statistically significant variables in the multivariable model. Adjusted mortality rates by birth weight and 5-min Apgar score were calculated for each intensive care unit. RESULTS: Low birth weight and 5-min Apgar score remained independently associated to death. Birth weight equal to 2,500g had 0.71 accuracy (95% CI: 0.65-0.77) for predicting neonatal death (sensitivity =72.2%). A wide variation in the mortality rates was found among intensive care units (9.5-48.1%) and two of them remained with significant high mortality rates even after adjusting for birth weight and 5-min Apgar score. CONCLUSIONS: This study corroborates birth weight as a sensitive screening variable in surveillance programs for neonatal death and also to target intensive care units with high mortality rates for implementing preventive actions and interventions during the delivery period.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE Develop an index to evaluate the maternal and neonatal hospital care of the Brazilian Unified Health System.METHODS This descriptive cross-sectional study of national scope was based on the structure-process-outcome framework proposed by Donabedian and on comprehensive health care. Data from the Hospital Information System and the National Registry of Health Establishments were used. The maternal and neonatal network of Brazilian Unified Health System consisted of 3,400 hospitals that performed at least 12 deliveries in 2009 or whose number of deliveries represented 10.0% or more of the total admissions in 2009. Relevance and reliability were defined as criteria for the selection of variables. Simple and composite indicators and the index of completeness were constructed and evaluated, and the distribution of maternal and neonatal hospital care was assessed in different regions of the country.RESULTS A total of 40 variables were selected, from which 27 single indicators, five composite indicators, and the index of completeness of care were built. Composite indicators were constructed by grouping simple indicators and included the following variables: hospital size, level of complexity, delivery care practice, recommended hospital practice, and epidemiological practice. The index of completeness of care grouped the five variables and classified them in ascending order, thereby yielding five levels of completeness of maternal and neonatal hospital care: very low, low, intermediate, high, and very high. The hospital network was predominantly of small size and low complexity, with inadequate child delivery care and poor development of recommended and epidemiological practices. The index showed that more than 80.0% hospitals had a low index of completeness of care and that most qualified heath care services were concentrated in the more developed regions of the country.CONCLUSIONS The index of completeness proved to be of great value for monitoring the maternal and neonatal hospital care of Brazilian Unified Health System and indicated that the quality of health care was unsatisfactory. However, its application does not replace specific evaluations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cytomegalovirus (CMV) infection is the most common congenital infection, affecting 0.4% to 2.3% newborns. Most of them are asymptomatic at birth, but later 10% develop handicaps, mainly neurological disturbances. Our aim was to determine the prevalence of CMV shed in urine of newborns from a neonatal intensive care unit using the polymerase chain reaction (PCR) and correlate positive cases to some perinatal aspects. Urine samples obtained at first week of life were processed according to a PCR protocol. Perinatal data were collected retrospectively from medical records. Twenty of the 292 cases (6.8%) were CMV-DNA positive. There was no statistical difference between newborns with and without CMV congenital infection concerning birth weight (p=0.11), gestational age (p=0.11), Apgar scores in the first and fifth minutes of life (p=0.99 and 0.16), mother's age (p=0.67) and gestational history. Moreover, CMV congenital infection was neither related to gender (p=0.55) nor to low weight (<2,500g) at birth (p=0.13). This high prevalence of CMV congenital infection (6.8%) could be due to the high sensitivity of PCR technique, the low socioeconomic level of studied population or the severe clinical status of these newborns.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: Report the incidence of nosocomial infections, causative microorganisms, risk factors associated with and antimicrobial susceptibility pattern in the NICU of the Uberlândia University Hospital. METHODS: Data were collected through the National Healthcare Safety Network surveillance from January 2006 to December 2009. The patients were followed five times/week from their birth to their discharge or death. RESULTS: The study included 1,443 patients, 209 of these developed NIs, totaling 293 NI episodes, principally bloodstream infections (203; 69.3%) and conjunctivitis (52; 17.7%). Device-associated infection rates were as follows: 17.3 primary bloodstream infections per 1,000 central line-days and 3.2 pneumonias per 1000 ventilator-days. The mortality rate in neonates with NI was 11.9%. Mechanical ventilation, total parenteral nutrition, orogastric tube, previous antibiotic therapy, use of CVC and birth weight of 751-1,000g appeared to be associated with a significantly higher risk of NI (p < 0.05). In multiple logistic regression analysis for NI, mechanical ventilation and the use of CVC were independent risk factors (p < 0.05). Coagulase- negative Staphylococcus (CoNS) (36.5%) and Staphylococcus aureus (23.6%) were the most common etiologic agents isolated from cultures. The incidences of oxacillin-resistant CoNS and S. aureus were 81.8% and 25.3%, respectively. CONCLUSIONS: Frequent surveillance was very important to evaluate the association of these well-known risk factors with NIs and causative organisms, assisting in drawing the attention of health care professionals to this potent cause of morbidity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction Surveillance of nosocomial infections (NIs) is an essential part of quality patient care; however, there are few reports of National Healthcare Safety Network (NHSN) surveillance in neonatal intensive care units (NICUs) and none in developing countries. The purpose of this study was to report the incidence of NIs, causative organisms, and antimicrobial susceptibility patterns in a large cohort of neonates admitted to the NICU during a 16-year period. Methods The patients were followed 5 times per week from birth to discharge or death, and epidemiological surveillance was conducted according to the NHSN. Results From January 1997 to December 2012, 4,615 neonates, representing 62,412 patient-days, were admitted to the NICU. The device-associated infection rates were as follows: 17.3 primary bloodstream infections per 1,000 central line-days and 3.2 pneumonia infections per 1,000 ventilator-days. A total of 1,182 microorganisms were isolated from sterile body site cultures in 902 neonates. Coagulase-negative staphylococci (CoNS) (34.3%) and Staphylococcus aureus (15.6%) were the most common etiologic agents isolated from cultures. The incidences of oxacillin-resistant CoNS and Staphylococcus aureus were 86.4% and 28.3%, respectively. Conclusions The most important NI remains bloodstream infection with staphylococci as the predominant pathogens, observed at much higher rates than those reported in the literature. Multiresistant microorganisms, especially oxacillin-resistant staphylococci and gram-negative bacilli resistant to cephalosporin were frequently found. Furthermore, by promoting strict hygiene measures and meticulous care of the infected infants, the process itself of evaluating the causative organisms was valuable.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: To determine the incidence and characteristics of nonimmune hydrops fetalis in the newborn population. METHOD: A retrospective study of the period between 1996 and 2000, including all newborns with a prenatal or early neonatal diagnosis of nonimmune hydrops fetalis, based on clinical history, physical examination, and laboratory evaluation. The following were analyzed: prenatal follow-up, delivery type, gender, birth weight, gestational age, presence of perinatal asphyxia, nutritional classification, etiopathic diagnosis, length of hospital stay, mortality, and age at death. RESULTS: A total of 47 newborns with hydrops fetalis (0.42% of live births), 18 (38.3%) with the immune form and 29 (61.7%) with the nonimmune form, were selected for study. The incidence of nonimmune hydrops fetalis was 1 per 414 neonates. Data was obtained from 21 newborns, with the following characteristics: 19 (90.5%) were suspected from prenatal diagnosis, 18 (85.7%) were born by cesarean delivery, 15 (71.4%) were female, and 10 (47.6%) were asphyxiated. The average weight was 2665.9 g, and the average gestational age was 35 3/7 weeks; 14 (66.6%) were preterm; 18 (85.0 %) appropriate delivery time; and 3 (14.3%) were large for gestational age. The etiopathic diagnosis was determined for 62%, which included cardiovascular (19.0%), infectious (9.5%), placental (4.8%), hematologic (4.7%), genitourinary (4.8%), and tumoral causes (4.8%), and there was a combination of causes in 9.5%. The etiology was classified as idiopathic in 38%. The length of hospital stay was 26.6 ± 23.6 days, and the mortality rate was 52.4%. CONCLUSIONS: The establishment of a suitable etiopathic diagnosis associated with prenatal detection of nonimmune hydrops fetalis can be an important step in reducing the neonatal mortality rate from this condition.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study had the objective of to analyze the demographic and bacteriologic data of 32 hospitalized newborns in an neonatal intensive care unit of a public maternity hospital in Rio de Janeiro city, Brazil, seized by Pseudomonas aeruginosa sepsis during a period ranged from July 1997 to July 1999, and to determine the antimicrobial resistance percentage, serotypes and pulsed field gel electrophoresis (PFGE) patterns of 32 strains isolated during this period. The study group presented mean age of 12.5 days, with higher prevalence of hospital infection in males (59.4%) and vaginal delivery (81.2%), than females (40.6%) and cesarean delivery (18.8%), respectively. In this group, 20 (62.5%) patients received antimicrobials before positive blood cultures presentation. A total of 87.5% of the patients were premature, 62.5% presented very low birth weight and 40.6% had asphyxia. We detected high antimicrobial resistance percentage to b-lactams, chloramphenicol, trimethoprim/sulfamethoxazole and tetracycline among the isolated strains. All isolated strains were classified as multi-drug resistant. Most strains presented serotype O11 while PFGE analysis revealed seven distinct clones with isolation predominance of a single clone (75%) isolated from July 1997 to June 1998.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess the effect of hospital of birth on neonatal mortality. METHODS: A birth cohort study was carried out in Pelotas, Southern Brazil, in 2004. All hospital births were assessed by daily visits to all maternity hospitals and 4558 deliveries were included in the study. Mothers were interviewed regarding potential risk factors. Deaths were monitored through regular visits to hospitals, cemeteries and register offices. Two independent pediatricians established the underlying cause of death based on information obtained from medical records and home visits to parents. Logistic regression was used to estimate the effect of hospital of birth, controlling for confounders related to maternal and newborn characteristics, according to a conceptual model. RESULTS: Neonatal mortality rate was 12.7‰ and it was highly influenced by birthweight, gestational age, and socioeconomic variables. Immaturity was responsible for 65% of neonatal deaths, followed by congenital anomalies, infections and intrapartum asphyxia. Adjusting for maternal characteristics, a three-fold increase in neonatal mortality was seen between similar complexity hospitals. The effect of hospital remained, though lower, after controlling for newborn characteristics. CONCLUSIONS: Neonatal mortality was high, mainly related to immaturity, and varied significantly across maternity hospitals. Further investigations comparing delivery care practices across hospitals are needed to better understand NMR variation and to develop strategies for neonatal mortality reduction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Group B Streptococcus is the most common pathogen found in neonatal sepsis in North America. OBJECTIVES: We describe 15 cases of neonatal infections by Group B Streptococcus (Streptococcus agalactiae) at a Neonatal Intensive Care Unit of a public and teaching hospital. METHODS: We conducted a study at Hospital de Clínicas de Porto Alegre, from January 1st, 1996 to June 30, 1999. Diagnosis of neonatal infection was established according to the findings of Group B Streptococcus in blood culture associated with alterations resembling sepsis on the basis of clinical picture and laboratory findings. RESULTS: Fifteen cases of neonatal infections by Group B Streptococcus were detected. Eleven cases consisted of early-onset sepsis, 2 cases of occult bacteremia and 2 cases of late-onset sepsis. Eight cases had septic shock (53%), 8 cases had pneumonia (53%), and 4 cases had meningitis (27%). Fourteen cases were diagnosed from a positive blood culture, and 1 case from evidence of these bacteria in pulmonary anatomopathological examination. Thirteen cases (87%) were diagnosed before 72 hours of life. We had 3 deaths (20%), and 3 cases of meningitis developing neurological deficits. CONCLUSIONS: Streptococcus Group B is one of the most important pathogens in the etiology of early-onset neonatal sepsis at our hospital, with high mortality and morbidity. However, we do not know the incidence of GBS neonatal infections at other hospitals. More data are needed to establish a basis for trials of different strategies to reduce these infections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Catheter-associated bloodstream infection (CA-BSI) is the most common nosocomial infection in neonatal intensive care units. There is evidence that care bundles to reduce CA-BSI are effective in the adult literature. The aim of this study was to reduce CA-BSI in a Brazilian neonatal intensive care unit by means of a care bundle including few strategies or procedures of prevention and control of these infections. METHODS: An intervention designed to reduce CA-BSI with five evidence-based procedures was conducted. RESULTS: A total of sixty-seven (26.7%) CA-BSIs were observed. There were 46 (32%) episodes of culture-proven sepsis in group preintervention (24.1 per 1,000 catheter days [CVC days]). Neonates in the group after implementation of the intervention had 21 (19.6%) episodes of CA-BSI (14.9 per 1,000 CVC days). The incidence of CA-BSI decreased significantly after the intervention from the group preintervention and postintervention (32% to 19.6%, 24.1 per 1,000 CVC days to 14.9 per 1,000 CVC days, p=0.04). In the multiple logistic regression analysis, the use of more than 3 antibiotics and length of stay >8 days were independent risk factors for BSI. CONCLUSIONS: A stepwise introduction of evidence-based intervention and intensive and continuous education of all healthcare workers are effective in reducing CA-BSI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coagulase-negative staphylococci (CoNS) are the microorganisms most frequently isolated from clinical samples and are commonly found in neonatal blood cultures. Oxacillin is an alternative treatment of choice for CoNS infections; however, resistance to oxacillin can have a substantial impact on healthcare by adversely affecting morbidity and mortality. The objective of this study was to detect and characterise oxacillin-resistant CoNS strains in blood cultures of newborns hospitalised at the neonatal ward of the University Hospital of the Faculty of Medicine of Botucatu. One hundred CoNS strains were isolated and the mecA gene was detected in 69 of the CoNS strains, including 73.2% of Staphylococcus epidermidis strains, 85.7% of Staphylococcus haemolyticus strains, 28.6% of Staphylococcus hominis strains and 50% of Staphylococcus lugdunensis strains. Among these oxacillin-resistant CoNS strains, staphylococcal cassette chromosome mec (SCCmec) type I was identified in 24.6%, type II in 4.3%, type III in 56.5% and type IV in 14.5% of the strains. The data revealed an increase in the percentage of CoNS strains isolated from blood cultures from 1991-2009. Furthermore, a predominant SCCmec profile of the oxacillin-resistant CoNS strains isolated from neonatal intensive care units was identified with a prevalence of SCCmec types found in hospital-acquired strains.