141 resultados para Mitral annular dynamic
Resumo:
OBJECTIVE: To evaluate echocardiography accuracy in performing and obtaining images for dynamical three-dimensional (3D) reconstruction. METHODS: Three-dimensional (3D) image reconstruction was obtained in 20 consecutive patients who underwent transesophageal echocardiography. A multiplanar 5 MHz transducer was used for 3D reconstruction. RESULTS: Twenty patients were studied consecutively. The following cardiac diseases were present: valvar prostheses-6 (2 mitral, 2 aortic and 2 mitral and aortic); mitral valve prolapse- 3; mitral and aortic disease - 2; aortic valve disease- 5; congenital heart disease- 3 (2 atrial septal defect- ASD - and 1 transposition of the great arteries -TGA); arteriovenous fistula- 1. In 7 patients, color Doppler was also obtained and used for 3D flow reconstruction. Twenty five cardiac structures were acquired and 60 reconstructions generated (28 of mitral valves, 14 of aortic valves, 4 of mitral prostheses, 7 of aortic prostheses and 7 of the ASD). Fifty five of 60 (91.6%) reconstructions were considered of good quality by 2 independent observers. The 11 reconstructed mitral valves/prostheses and the 2 reconstructed ASDs provided more anatomical information than two dimensional echocardiography (2DE) alone. CONCLUSION: 3D echocardiography using a transesophageal transducer is a feasible technique, which improves detection of anatomical details of cardiac structures, particularly of the mitral valve and atrial septum.
Resumo:
OBJECTIVE: To analyze late clinical evolution after surgical treatment of children, with reparative and reconstructive techniques without annular support. METHODS: We evaluated 21 patients operated upon between 1975 and 1998. Age 4.67±3.44 years; 47.6% girls; mitral insufficiency 57.1% (12 cases), stenosis 28.6% (6 cases), and double lesion 14.3% (3 cases). The perfusion 43.10±9.50min, and ischemia time were 29.40±10.50min. The average clinical follow-up in mitral insufficiency was 41.52±53.61 months. In the stenosis group (4 patients) was 46.39±32.02 months, and in the double lesion group (3 patients), 39.41±37.5 months. The echocardiographic follow-up was in mitral insufficiency 37.17±39.51 months, stenosis 42.61±30.59 months, and in the double lesion 39.41±37.51 months. RESULTS: Operative mortality was 9.5% (2 cases). No late deaths occurred. In the group with mitral insufficiency, 10 (83.3%) patients were asymptomatic (p=0.04). The majorit y with mild reflux (p=0.002). In the follow-up of the stenosis group, all were in functional class I (NYHA); and the mean transvalve gradient varied between 8 and 12mmHg, average of 10.7mmHg. In the double lesion group, 1 patient was reoperated at 43 months. No endocarditis or thromboembolism were reported. CONCLUSION: Mitral stenosis repair has worse late results, related to the valve abnormalities and associated lesions. The correction of mitral insufficiency without annular support showed good long-term results.
Resumo:
O Dynamic Gait Index (DGI) é um teste que avalia o equilíbrio e marcha do corpo humano. OBJETIVOS: Os objetivos deste estudo foram adaptar culturalmente o DGI para o português e avaliar a sua confiabilidade. MATERIAL E MÉTODO: Seguiu-se o método de Guillemin et al. (1993) para a adaptação cultural do instrumento. Trata-se de estudo prospectivo em que 46 pacientes foram avaliados na fase de adaptação cultural e os itens que apresentaram 20% ou mais de incompreensão foram reformulados e reaplicados. A versão final do DGI em português foi aplicada em 35 idosos para examinar a confiabilidade intra e inter-observadores. O coeficiente de Spearman foi utilizado para correlacionar os escores inter e intra-observador e o teste de Wilcoxon para comparar as pontuações. A consistência interna foi analisada pelo coeficiente alfa de Cronbach. RESULTADOS: Houve correlações estatisticamente significantes entre os escores obtidos às avaliações inter e intra-observadores para todos os itens (p<0,001), classificadas como boa a muito forte (com de variação de r=0,655 a r=0,951). O DGI mostrou alta consistência interna entre seus itens nas avaliações inter e intra-observadores (variação de µ ou = 0,820 a a=0,894). CONCLUSÃO: O DGI foi adaptado culturalmente para o português brasileiro, mostrando-se um instrumento confiável.
Resumo:
In order to sustain their competitive advantage in the current increasingly globalized and turbulent context, more and more firms are competing globally in alliances and networks that oblige them to adopt new managerial paradigms and tools. However, their strategic analyses rarely take into account the strategic implications of these alliances and networks, considering their global relational characteristics, admittedly because of a lack of adequate tools to do so. This paper contributes to research that seeks to fill this gap by proposing the Global Strategic Network Analysis - SNA - framework. Its purpose is to help firms that compete globally in alliances and networks to carry out their strategic assessments and decision-making with a view to ensuring dynamic strategic fit from both a global and relational perspective.
Resumo:
A mathematical model for the purpose of analysing the dynamic of the populations of infected hosts anf infected mosquitoes when the populations of mosquitoes are periodic in time is here presented. By the computation of a parameter lambda (the spectral radius of a certain monodromy matrix) one can state that either the infection peters out naturally) (lambda <= 1) or if lambda > 1 the infection becomes endemic. The model generalizes previous models for malaria by considering the case of periodic coefficients; it is also a variation of that for gonorrhea. The main motivation for the consideration of this present model was the recent studies on mosquitoes at an experimental rice irrigation system, in the South-Eastern region of Brazil.
Resumo:
ABSTRACT OBJECTIVE To develop an assessment tool to evaluate the efficiency of federal university general hospitals. METHODS Data envelopment analysis, a linear programming technique, creates a best practice frontier by comparing observed production given the amount of resources used. The model is output-oriented and considers variable returns to scale. Network data envelopment analysis considers link variables belonging to more than one dimension (in the model, medical residents, adjusted admissions, and research projects). Dynamic network data envelopment analysis uses carry-over variables (in the model, financing budget) to analyze frontier shift in subsequent years. Data were gathered from the information system of the Brazilian Ministry of Education (MEC), 2010-2013. RESULTS The mean scores for health care, teaching and research over the period were 58.0%, 86.0%, and 61.0%, respectively. In 2012, the best performance year, for all units to reach the frontier it would be necessary to have a mean increase of 65.0% in outpatient visits; 34.0% in admissions; 12.0% in undergraduate students; 13.0% in multi-professional residents; 48.0% in graduate students; 7.0% in research projects; besides a decrease of 9.0% in medical residents. In the same year, an increase of 0.9% in financing budget would be necessary to improve the care output frontier. In the dynamic evaluation, there was progress in teaching efficiency, oscillation in medical care and no variation in research. CONCLUSIONS The proposed model generates public health planning and programming parameters by estimating efficiency scores and making projections to reach the best practice frontier.
Resumo:
We have studied the cardiac chronotropic responses to the Valsalva maneuver and to dynamic exercise of twenty chronic chagasic patients with normal left ventricular function and no segmental wall abnormalities by two-dimensional echocardiogram. The absolute increase in heart rate of the patients (Δ = 21.5 ± 10 bpm, M±SD) during the maneuver was significantly diminished when compared to controls (Δ = 31.30 ± 70, M±SD, p = 0.03). The minimum heart rate (58.24 ± 8.90 vs. 62.80 ± 10, p = 0.68) and the absolute decrease in heart rate at the end of the maneuver (Δ = 38.30 ± 13 vs. Δ = 31.47 ± 17, p = 0.10) were not different from controls. The initial heart rate acceleration during dynamic exercise (Δ = 12 ± 7.55 vs. Δ = 19 ± 7.27, M±SD, p = 0.01) was also diminished, but the heart rate recovery during the first ten seconds was more prominent in the sero-positive patients (Median: 14, Interquartile range: (9.75-17.50 vs. 5(0-8.75, p = 0.001). The serum levels of muscarinic cardiac auto-antibodies were significantly higher in the chagasic patients (Median: 34.58, Interquartile Range: 17-46.5, Optical Density) than in controls (Median: 0, Interquartile Range: 0-22.25, p = 0.001) and correlated significantly and directly (r = 0.68, p = 0.002) with early heart rate recovery during dynamic exercise. The results of this investigation indirectly suggest that, the cardiac muscarinic auto-antibodies may have positive agonist effects on parasympathetic heart rate control of chagasic patients.
Resumo:
INTRODUCTION: Sylvatic yellow fever (SYF) is enzootic in Brazil, causing periodic outbreaks in humans living near forest borders or in rural areas. In this study, the cycling patterns of this arbovirosis were analyzed. METHODS: Spectral Fourier analysis was used to capture the periodicity patterns of SYF in time series. RESULTS: SYF outbreaks have not increased in frequency, only in the number of cases. There are two dominant cycles in SYF outbreaks, a seven year cycle for the central-western region and a 14 year cycle for the northern region. Most of the variance was concentrated in the central-western region and dominated the entire endemic region. CONCLUSIONS: The seven year cycle is predominant in the endemic region of the disease due the greater contribution of variance in the central-western region; however, it was possible identify a 14 cycle that governs SYF outbreaks in the northern region. No periodicities were identified for the remaining geographical regions.
Resumo:
PURPOSE: The dura mater bioprosthesis was developed in the Department of Cardiopneumology of the Hospital das Clínicas of the University of São Paulo Medical School in 1971. Here, we present the clinical results of the dura mater bioprosthesis over 30 years of follow-up. METHODS: We studied 70 consecutive patients who underwent mitral or tricuspid valve replacement with a dura mater bioprosthesis between January 1971 and August 1972. RESULTS: The early mortality was 10% (7 patients). The follow-up was 87% complete (9 patients were lost to follow-up). Two patients were alive and asymptomatic 30 years after valve replacement; 33 patients underwent reoperations due to valve dysfunction, and 19 died during the follow-up period. At 30 years, the actuarial survival was 49.2 ± 8.6%; freedom from rupture, 27.0 ± 10.2%; freedom from calcification, 78.8 ± 8.6%; and freedom from reoperation, 18.8 ± 7.5%. CONCLUSIONS: The dura mater bioprosthesis played an important role in the treatment of patients with mitral and tricuspid valve disease. The low rate of thromboembolism and the long period of follow-up without evidence of valve dysfunction, which occurred for several of our patients, are important characteristics of these bioprosthesis.
Resumo:
Gestante com 33 anos na 28ª semana e sinais de óbito fetal foi admitida em caráter de urgência com quadro de edema pulmonar agudo secundário à estenose mitral grave. Com o insucesso do tratamento medicamentoso intensivo, a paciente foi submetida à valvoplastia mitral percutânea de emergência com melhora imediata. O agravamento subseqüente do quadro, atribuído ao óbito fetal, foi tratado através parto cesáreo com melhora clínica considerável. A paciente teve alta hospitalar no 10º dia, e 11 meses após o procedimento, encontra-se em classe funcional I, sem uso de medicação e com sinais ecocardiográficos de estenose mitral leve (área valvar: 2,0 cm²).
Resumo:
OBJETIVO: Estudar o arranjo espacial dos elementos fibrosos que constituem os folhetos da valva mitral e do seu anel fibroso. MÉTODOS: Foram utilizados 20 corações adultos, de ambos os sexos, fixados em formol a 10%. Isolaram-se a valva mitral, juntamente com o anel fibroso, e uma pequena quantidade de tecido muscular ao seu redor. Parte desse material foi incluído em parafina, submetido a cortes seriados de 40µm de espessura e corados pelo tricrômio de Azan e pela resorcina-fucsina, e o restante das peças dissecadas sob lupa estereoscópica, com ajuda de delicadas pinças e agulhas, para se observar a disposição dos feixes miocárdicos ao nível do anel mitral. RESULTADOS: Observou-se que o anel fibroso mitral era constituído por feixes colágenos de trajetória semicircular, envolvendo de forma incompleta o óstio atrioventricular, uma vez que era ausente na região ântero-medial do óstio. Verificou-se que os feixes miocárdicos ventriculares inseriam-se de forma oblíqua, na borda externa do anel, sendo que na região ântero-medial assumiam uma trajetória semicircular. Os folhetos da valva mitral eram constituídos de feixes colágenos dispostos, paralelamente, no sentido do maior eixo da válvula, recobertos pelo endocárdio atrial e ventricular. Os feixes colágenos, presentes na base dos folhetos valvares, praticamente se continuavam com os do anel fibroso. Observou-se, em alguns casos, a existência de delgados feixes miocárdios atriais no folheto valvar anterior, que praticamente eram restritos à região central das válvulas. CONCLUSÃO: Os folhetos da valva mitral e seu anel fibroso possuem uma continuidade estrutural, que demonstra que estes elementos funcionam de forma integrada no fechamento do óstio atrioventricular esquerdo durante a sístole ventricular, no que seria auxiliado pela redução do diâmetro do anel fibroso, através da contração dos feixes miocárdicos semicirculares que nele se inserem.
Resumo:
OBJETIVO: Avaliação não invasiva das respostas cardiopulmonares ao exercício a curto e longo prazo após valvotomia mitral por cateter balão. MÉTODOS: Estudaram-se 9 pacientes do sexo feminino, 35±9 anos, com estenose mitral, tipo funcional II ou III, em uso de digitálicos e diuréticos, através de teste ergoespirométrico, eletrocardiograma e ecocardiograma, antes e após valvotomia em fase precoce (3 a 5 dias) e tardia (8 a 12 meses). RESULTADOS: Os pacientes evoluíram para tipo funcional II (44%) ou I (56%), na fase tardia. Houve redução da freqüência cardíaca de repouso (87±11bpm vs 85±7bpm vs 75±9bpm) e elevação do número de estágios (4±1 estágios vs 5±2 estágios vs 6±1 estágios); a capacidade aeróbia máxima aumentou apenas na fase tardia (16±3mL/kg/min vs 18±4mL/kg/min vs 22±7mL/kg/min). O limiar anaeróbio, a ventilação pulmonar e o equivalente ventilatório do O2 permaneceram inalterados. Nas cargas submáximas de exercício ocorreu redução da freqüência cardíaca (estágio I: 124±18bpm vs 112±13bpm vs 87±15bpm), consumo de O2 (estágio I: 10±2mL/kg/min vs 8±2mL/kg/min vs 8±mL/kg/min) e ventilação pulmonar, nas fases precoce e tardia. A área valvar mitral mostrou reduções na fase tardia (0,94cm² vs 1,66cm² vs 1,20cm² ). CONCLUSÃO: Apesar da tendência à reestenose parcial, houve melhora no tipo funcional e no desempenho cardiopulmonar com diminuição da sobrecarga circulatória no exercício submáximo.
Avaliação comparativa entre valvoplastia percutânea e comissurotomia a céu aberto na estenose mitral
Resumo:
OBJETIVO: Comparar resultados imediatos e após 12 meses de seguimento entre valvoplastia por balão e comissurotomia na estenose mitral. MÉTODOS: Oitenta e oito portadores de estenose mitral sintomáticos com anatomia favorável foram randomizados nos dois grupos. Todos os pacientes submeteram-se a avaliação clínica e Doppler ecocardiográfica antes, imediatamente após e 12 meses depois do procedimento. RESULTADOS: Gradiente médio mitral (mmHg) diminuiu (p<0,001) de 12,18±5,84 para 5,80±2,66 no grupo comissurotomia (GC) e de 11,66±6,13 para 4,98±2,40 (p<0,001) no grupo valvuloplastia (GV). Área valvar mitral (cm²) aumentou de 0,98±0,21 para 2,52±0,46 no GC e de 1,05±0,25 para 2,18±0,40 no GV (p<0,001). Em ambos os grupos ocorreu uma diminuição discreta na área valvar mitral ao final do acompanhamento. Não ocorreram óbitos. Um paciente do GV apresentou insuficiência mitral significativa e necessitou tratamento cirúrgico. Aos 12 meses de acompanhamento todos os pacientes do GC e 97,7% dos pacientes do GV estavam em classe funcional I ou II (NYHA). CONCLUSÃO: Os procedimentos foram seguros e mostraram melhora semelhante no gradiente mitral e classe funcional. A área valvar mitral aumentou expressivamente mais no GC, e apresentou, também, uma redução mais significativa após 12 meses. A maioria dos pacientes não alterou a classe funcional no acompanhamento.
Resumo:
OBJETIVO: Avaliar os resultados imediatos e complicações da valvoplastia mitral percutânea por balão (VMPB), com o balão de Inoue (BI) e com o balão único (BU). MÉTODOS: Dentre 390 procedimentos utilizaram-se o BI em 29 procedimentos e o BU de baixo perfil em 337. Não houve diferença na idade e sexo nos 2 grupos. O grupo BI era menos sintomático (p=0,0015). Não houve diferença na distribuição do escore ecocardiográfico e da área valvar mitral (AVM) pré-VMPB. RESULTADOS: Quando compararam-se os 2 grupos entre si, os resultados nos grupos BI e BU foram, respectivamente: pré-VMPB para pressão pulmonar média (PPM) 36±15 e 39±14mmHg, p=0,2033, para gradiente (GRAD) mitral médio 17±6 e 20±7mmHg, p=0,0396 e AVM 0,9±0,2 e 0,9±9,2cm², p=0,8043, enquanto os valores pós-VMPB foram PPM 25±8 e 28±10mmHg, p=0,2881, GRAD 5±3 e 5±4mmHg, p=0,2778 e AVM 2,2±0,2 e 2,0±0,4cm², p=0,0362. Pré-VMPB a válvula mitral era competente em 26 procedimentos com o BI e 280 dos com o BU e havia regurgitação mitral de +/4 em 3 do grupo BI e em 57 do BU, p=0,3591 e pós-VMPB tivemos, no grupo BI a valva mitral (VM) competente em 18, +/4 em 7 e 2+/4 em 4 e no grupo BU, a VM era competente em 218, +/4 em 80, 2+/4 em 25, 3+/4 em 5 e 4+/4 em 2, p=0,7439. Só houve complicações no grupo BU. CONCLUSÃO: As duas técnicas foram eficientes. Os resultados hemodinâmicos foram semelhantes, embora a AVM pós-VMPB do grupo do BI foi maior.