2 resultados para spray drying

em Bioline International


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To compare oral bioavailability and pharmacokinetic parameters of different lornoxicam formulations and to assess similarity in plasma level profiles by statistical techniques. Methods: An open-label, two-period crossover trial was followed in 24 healthy Pakistani volunteers (22 males, 2 females). Each participant received a single dose of lornoxicam controlled release (CR) microparticles and two doses (morning and evening) of conventional lornoxicam immediate release (IR) tablet formulation. The microparticles were prepared by spray drying method. The formulations were administered again in an alternate manner after a washout period of one week. Pharmacokinetic parameters were determined by Kinetica 4.0 software using plasma concentration-time data. Moreover, data were statistically analyzed at 90 % confidence interval (CI) and Schuirmann’s two one-sided t-test procedure. Results: Peak plasma concentration (Cmax) was 20.2 % lower for CR formulation compared to IR formulation (270.90 ng/ml vs 339.44 ng/ml, respectively) while time taken to attain Cmax (tmax) was 5.25 and 2.08 h, respectively. Area under the plasma drug level versus time (AUC) curve was comparable for both CR and IR formulations. The 90 % confidence interval (CI) values computed for Cmax, AUC0-24, and AUC0-∞ , after log transformation, were 87.21, 108.51 and 102.74 %, respectively, and were within predefined bioequivalence range (80 - 125 %). Conclusion: The findings suggest that CR formulation of lornoxicam did not change the overall pharmacokinetic properties of lornoxicam in terms of extent and rate of lornoxicam absorption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Tracheal intubation is extremely distressing, painful, and may influence heart rate and blood pressure. Sedatives, analgesics, and muscle relaxants are not commonly used for intubation in neonates. Objectives: This study aimed to evaluate the effects of lidocaine spray as a non-intravenous drug before neonatal intubation on blood pressure, heart rate, oxygen saturation and time of intubation. Patients and Methods: In a randomized, controlled study each neonate was randomly assigned to one of the two study groups by staffs who were not involved in the infant's care. The allocation concealment was kept in an opaque sealed envelope, and the investigators, the patient care team, and the assessors were blinded to the treatment allocation. The selected setting was NICU unit of a teaching hospital in Ilam city, Iran and participants were 60 neonates with indication of tracheal intubation with gestational age >30 weeks. Patients in the treatment group received lidocaine spray and the placebo group received spray of normal saline prior to intubation. Main outcome measurements were the mean rates of blood pressure, heart rate, oxygen saturation, intubation time and lidocaine side effects were measured before and after intubation. Results: Totally 60 newborns including 31 boys and 29 girls were entered into the study (drug group n = 30; placebo group n = 30). Boy/girl ratio in treatment and placebo groups were 1.3 and 0.88, respectively. Mean age ± SD of participants was 34.1 ± 24.8 hours (treatment: 35.3 ± 25.7; placebo: 32.9 ± 24.3; P < 0.0001). Mean weight ± SD of neonates was 2012.5 ± 969 g. Application of lidocaine spray caused a significant reduction of mean intubation time among treatment group compared with placebo group (treatment: 15.03 ± 2.2 seconds; placebo: 18.3 ± 2.3 seconds; P < 0.0001). Mean blood pressure, heart rate and oxygen saturation rate, among neonates in treatment group was reduced after intubation compared with their relevant figures before intubation; however, their differences were not statistically significant except for mean oxygen saturation rate that was reduced significantly in placebo group. No side effects were observed during study. Conclusions: Though the current study revealed some promising results in the application of lidocaine spray during neonatal intubation without any considerable side effects; however, the current investigation could only be considered as a pilot study for further attempts in different locations with higher sample sizes and in different situations.