2 resultados para ocular ultrasonography

em Bioline International


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The work environment of cocoa farmers exposes them to several ocular hazards that predispose them to eye diseases and injuries. However, the extent of ocular injuries and health seeking patterns following these injuries are unknown among cocoa farmers in Ghana. Objectives: To determine the prevalence of ocular injuries and health seeking behaviour following injury among cocoa farmers in Ghana. Methods: Five hundred and fifty six participants were recruited through simple random sampling using a multistage approach from four cocoa growing districts in Ghana. A structured questionnaire was used to collect relevant information such as demography, ocular hazards and injuries experienced. An ocular examination was also conducted to assess the eye health of the participants. Descriptive and regression statistics were used to analyze the data. The rate of ocular injuries was calculated by using the number of injuries reported that resulted in lost work time/days divided by the number of worker years at risk of injury (sum of years worked in cocoa farms for all the participants). Results: The rate of ocular injuries was 11.3/1000 worker years (95% CI: 9.4 - 31) which led to lost work time of 37.3/1000 worker years (95% CI: 34.1 - 40.8). The major causes of ocular injury were plants/branches (n=73, 51.1%), chemicals (n=27, 18.9%), cocoa pod/husk (n=14, 9.8%) and occurred mostly during weeding, harvesting and chemical spraying. Few (n=34, 6.1%) participants reported the use of ocular protection. Fifty-five (38.5%) participants visited the local chemical shops, while 37 (25.9%) visited hospitals/clinics for ocular treatment of their injuries. Conclusion: There is a high rate of ocular injuries among cocoa farmers who make insufficient use of appropriate eye care services. There is the need for eye health education among cocoa farmers in Ghana. Keywords:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the reliability of analysis of only 0-1min clips and 1-4min clips versus the entire clips in performing contrast-enhanced ultrasonography (CEUS) of focal liver lesions (FLLs). Methods: Contrast-enhanced ultrasonography (CEUS) examinations of 43 single FLLs were performed. All clips were analyzed in three ways, the entire clips, 0-1 min clips and 1-4 min clips, benign or malignant diagnosis and pathological diagnosis of each FLL were concluded by the three ways subsequently. Results: The results of correct diagnosis were assessed using Chi-square test. There was no difference with regard to benign or malignant diagnosis, between 0-1min clips and the entire clips, or between 1-4 min clips and the entire clips (p = 0.243 and p = 0.747, respectively). Moreover, no significant differences in pathological diagnosis existed between 0-1min clips and the entire clips, and 1- 4min clips versus entire clips (p=0.808 and p = 0.808, respectively). No significant differences existed among CEUS entire clip, 0-1min clip and 1-4min clip in identifying FLLs, and based on which the diagnosis of two different FLLs during CEUS with only one injection of contrast agent can be available. Conclusion: Only 0-1min clips or 1-4 min clips can be used to instead of the entre clip in performing CEUS of FLLs.