8 resultados para newborn with LBW

em Bioline International


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim Quality of service delivery for maternal and newborn health in Malawi is influenced by human resource shortages and knowledge and care practices of the existing service providers. We assessed Malawian healthcare providers’ knowledge of management of routine labour, emergency obstetric care and emergency newborn care; correlated knowledge with reported confidence and previous study or training; and measured perception of the care they provided. Methods his study formed part of a large-scale quality of care assessment in three districts (Kasungu, Lilongwe and Salima) of Malawi. Subjects were selected purposively by their role as providers of obstetric and newborn care during routine visits to health facilities by a research assistant. Research assistants introduced and supervised the self-completed questionnaire by the service providers. Respondents included 42 nurse midwives, 1 clinical officer, 4 medical assistants and 5 other staff. Of these, 37 were staff working in facilities providing Basic Emergency Obstetric Care (BEMoC) and 15 were from staff working in facilities providing Comprehensive Emergency Obstetric Care (CEMoC). Results Knowledge regarding management of routine labour was good (80% correct responses), but knowledge of correct monitoring during routine labour (35% correct) was not in keeping with internationally recognized good practice. Questions regarding emergency obstetric care were answered correctly by 70% of respondents with significant variation depending on clinicians’ place of work. Knowledge of emergency newborn care was poor across all groups surveyed with 58% correct responses and high rates of potentially life-threatening responses from BEmOC facilities. Reported confidence and training had little impact on levels of knowledge. Staff in general reported perception of poor quality of care. Conclusion Serious deficiencies in providers’ knowledge regarding monitoring during routine labour and management of emergency newborn care were documented. These may contribute to maternal and neonatal deaths in Malawi. The knowledge gap cannot be overcome by simply providing more training.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Nosocomial sepsis (NS) in newborns (NBs) is associated with high mortality rates and low microbial recovery rates. To overcome the latter problem, new techniques in molecular biology are being used. Objectives: To evaluate the diagnostic efficacy of SeptiFast test for the diagnosis of nosocomial sepsis in the newborn. Materials and Methods: 86 blood specimens of NBs with suspected NS (NOSEP-1 Test > 8 points) were analyzed using Light Cycler SeptiFast (LC-SF) a real-time multiplex PCR instrument. The results were analyzed with the Roche SeptiFast Identification Software. Another blood sample was collected to carry out a blood culture (BC). Results: Sensitivity (Sn) and specificity (Sp) of 0.69 and 0.65 respectively, compared with blood culture (BC) were obtained for LC-SF. Kappa index concordance between LC-SF and BC was 0.21. Thirteen (15.11%) samples were BC positive and 34 (31.39%) were positive with LC-SF tests. Conclusions: Compared with BC, LC-SF allows the detection of a greater number of pathogenic species in a small blood sample (1 mL) with a shorter response time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Respiratory distress syndrome (RDS) is one of the most common causes of neonatal respiratory failure and mortality. The risk of developing RDS decreases with both increasing gestational age and birth weight. Objectives: The aim of this study was to evaluate the value of lung ultrasound in the diagnosis of respiratory distress syndrome (RDS) in newborn infants. Materials and Methods: From March 2012 to May 2013, 100 newborn infants were divided into two groups: RDS group (50 cases) and control group (50 cases). According to the findings of chest x-ray, there were 10 cases of grade II RDS, 15 grade III cases, and 25 grade IV cases in RDS group. Lung ultrasound was performed at bedside by a single expert. The ultrasound indexes observed in this study included pleural line, A-line, B-line, lung consolidation, air bronchograms, bilateral white lung, interstitial syndrome, lung sliding, lung pulse etc. Results: In all of the infants with RDS, lung ultrasound consistently showed generalized consolidation with air bronchograms, bilateral white lung or alveolar-interstitial syndrome, pleural line abnormalities, A-line disappearance, pleural effusion, lung pulse, etc. The simultaneous demonstration of lung consolidation, pleural line abnormalities and bilateral white lung, or lung consolidation, pleural line abnormalities and A-line disappearance co-exists with a sensitivity and specificity of 100%. Besides, the sensitivity was 80% and specificity 100% of lung pulse for the diagnosis of neonatal RDS. Conclusions: This study indicates that using an ultrasound to diagnose neonatal RDS is accurate and reliable too. A lung ultrasound has many advantages over other techniques. Ultrasound is non-ionizing, low-cost, easy to operate, and can be performed at bedside, making this technique ideal for use in NICU.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Umbilical arterial blood gas (UABG) analysis is more objective than other methods for predicting neonatal outcome. Acidemic neonates may be at risk for unfavorable outcome after birth, but all neonates with abnormal arterial blood gas (ABG) analysis do not always have poor outcome. Objectives: This study was carried out to determine the short term outcome of the neonates born with an abnormal ABG. Patients and Methods: In a cohort prospective study 120 high risk mother-neonate pairs were enrolled and UABG was taken immediately after birth. All neonates with an umbilical cord pH less than 7.2 were considered as case group and more than 7.2 as controls. Outcomes like need to resuscitation, admission to newborn services and/or NICU), seizure occurrence, hypoxic ischemic encephalopathy (HIE), delayed initiation of oral feeding and length of hospital stay were recorded and compared between the two groups. P value less than 0.05 was considered as being significant. Results: Comparison of short term outcomes between normal and abnormal ABG groups were as the fallowing: need for advanced resuscitation 4 vs. 0 (P = 0.001), NICU admission 16 vs. 4 (P = 0.001), convulsion 2 vs. 0 (P = 0.496), HIE 17 vs. 4 (P = 0.002), delay to start oral feeding 16 vs. 4 (P = 0.001), mean hospital stay 4 vs. 3 days (P = 0.001). None of the neonates died in study groups. Conclusions: An umbilical cord PH less than 7.2 immediately after birth can be used as a prognostic factor for unfavorable short term outcome in newborns.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Although it is well described among adults, intravenous colistin use and its associated toxicities in newborns are poorly understood. Objectives: We present our experience of efficacy and safety of intravenous colistin in the treatment of sepsis in term and preterm neonates. Patients and Methods: The records of neonates who received colistin between January 2013 and February 2014 were retrospectively reviewed. All neonates with culture proven nosocomial infections due to multidrug resistant organisms and treated continuously with colistin for more than 72 hours were included in the study. Results: Patients were evaluated for clinical and microbiological response to the drug and its and side effects. Twelve newborn infants with mean 31.8 ± 3.5 weeks gestational age and median 1482 (810 - 3200) gram birth weight were included. 11/12 (91.7%) patients showed microbiological clearance with intravenous colistin. One patient who had recurrent cerebrospinal fluid positive culture was treated with intraventricular colistin. The major side effects observed was hyponatremia and hypokalemia in 2 (16.6%) patients, all infants required magnesium supplementation. Conclusions: Intravenous colistin administration appears to be safe and efficacious for multidrug-resistant gram-negative infections in neonates, including preterm infants. However, we believe that large prospective controlled studies are needed to confirm its efficacy and safety in neonates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The most common reason of respiratory distress in the newborn is transient tachypnea of the newborn (TTN). There are some reports saying that TTN is associated with increased frequencies of wheezing attacks. Objectives: The aims of this study were to determine the risk factors associated with TTN and to determine the association between TTN and the development of wheezing syndromes in early life. Materials and Methods: In a historical cohort study, we recorded the characteristics of 70 infants born at the Shohadaye Kargar Hospital in Yazd between March 2005 and March 2009 and who were hospitalized because of TTN in the neonatal intensive-care unit. We called their parents at least four years after the infants were discharged from the hospital and asked about any wheezing attacks. Seventy other infants with no health problems during the newborn period were included in the study as the control group. Results: The rate of wheezing attacks in newborns with TTN was more than patients with no TTN diagnosis (P = 0.014). TTN was found to be an independent risk factor for later wheezing attacks (relative risk [RR] = 2.8). Conclusions: The most obvious finding of this study was that TTN was an independent risk factor for wheezing attacks. So long-term medical care is suggested for these patients who may be at risk, because TTN may not be as transient as has been previously thought.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: ABCA3 glycoprotein belongs to the ATP-binding cassette (ABC) superfamily of transporters, which utilize the energy derived from hydrolysis of ATP for the translocation of a wide variety of substrates across the plasma membrane. Mutations in the ABCA3 gene are knowingly causative for fatal surfactant deficiency, particularly respiratory distress syndrome (RDS) in term babies. Case Presentation: In this study, Sanger sequencing of the whole ABCA3 gene (NCBI NM_001089) was performed in a neonatal boy with severe RDS. A homozygous mutation has been identified in the patient. Parents were heterozygous for the same missense mutation GGA > AGA at position 202 in exon 6 of the ABCA3 gene (c.604G > A; p.G202R). Furthermore, 70 normal individuals have been analyzed for the mentioned change with negative results. Conclusions: Regarding Human Genome Mutation Database (HGMD) and other literature recherche, the detected change is a novel mutation and has not been reported before. Bioinformatics mutation predicting tools prefer it as pathogenic.