2 resultados para creatinine clearance
em Bioline International
Resumo:
Background: To achieve good outcomes in critically ill obstetric patients, it is necessary to identify organ dysfunction rapidly so that life-saving interventions can be appropriately commenced. However, timely access to clinical chemistry results is problematic, even in referral institutions, in the sub-Saharan African region. Reliable point-of-care tests licensed for clinical use are now available for lactate and creatinine. Aim: We aimed to assess whether implementation of point-of-care testing for lactate and creatinine is feasible in the obstetric unit at the Queen Elizabeth Central Hospital (QECH) in Blantyre, Malawi, by obtaining the opinions of clinical staff on the use of these tests in practice. Methods: During a two-month evaluation period nurse-midwives, medical interns, clinical officers, registrars, and consultants were given the opportunity to use StatStrip® and StatSensor® (Nova Biomedical, Waltham, USA) devices, for lactate and creatinine estimation, as part of their routine clinical practice in the obstetric unit. They were subsequently asked to complete a short questionnaire. Results: Thirty-seven questionnaires were returned by participants: 22 from nurse-midwives and the remainder from clinicians. The mean satisfaction score for the devices was 7.6/10 amongst clinicians and 8.0/10 amongst nurse-midwives. The majority of participants stated that the obstetric high dependency unit (HDU) was the most suitable location for the devices. For lactate, 31 participants strongly agreed that testing should be continued and 24 strongly agreed that it would influence patient management. For creatinine, 29 strongly agreed that testing should be continued and 28 strongly agreed that it would influence their patient management. Twenty participants strongly agreed that they trust point-of-care devices. Conclusions: Point-of-care clinical chemistry testing was feasible, practical, and well received by staff, and was considered to have a useful role to play in the clinical care of sick obstetric patients at this referral centre.
Resumo:
Purpose: To observe the clinical effects of sirolimus (SRL) immunosuppressive therapy in patients with progressively increasing levels of serum creatinine (Scr) after renal transplant. Methods: In total, 180 patients whose Scr levels had been rising after renal transplant were given an oral calcineurin inhibitor (CNI): either cyclosporine A (CsA) or tacrolimus (FK506). All patients were treated at People’s Hospital of Zhengzhou, China, between January 2011 and December 2013, and were given SRL-based conversion treatment. Scr level and glomerular filtration rate (GFR) were observed before and 1, 3, and 6 months after treatment initiation. In addition, liver function, blood glucose, blood lipid levels, rejection reaction incidence, and mortality were recorded to evaluate the effects of SRL. Results: Scr levels were 116.60 ± 30.60 μmol/L and 119.00 ± 24.60 μmol/L, and GFR was 70.00 ± 19.70 mL/min and 75.90 ± 15.60 mL/min, at 3 and 6 months after treatment, respectively. The 3- and 6- month Scr and GFR values were statistically different (p < 0.05) compared to pre-treatment levels (Scr: 144.10 ± 61.70 μmol/L vs and GFR: 59.10 ± 16.20 mL/min. Acute rejection (AR) occurred in 20 patients (13.30 %) within 6 months of treatment initiation, but rejection was reversed with conventional methylprednisolone therapy. Twenty-one patients (11.70 %) developed lung infections, but all were cured. There were no significant differences in liver function before and after treatment. Conclusion: SRL-based immunosuppressive therapy is effective in treating patients with increased Scr levels after renal transplant.