2 resultados para Radionuclide ventriculography
em Bioline International
Resumo:
Presence and concentrations of radionuclides could be as a result of natural and human activities. This study examined the associations and differences among soil, sediment and water specific activities of long-lived radioactive element (LLRE). Gamma spectroscopy was used to measure the concentration of the LLRE along the Mini Okoro/Oginigba Creek, Port Harcourt. Specific activities of three selected LLRE were derived. Correlation analysis was carried out to examine associations among the specific activities across different substrates. A strong and a significant negative correlation exists between the specific activities of Water 40K and Soil 232Th (r =-0.721, p<0.05); Water 238U and Soil 238U (r = -0.717, p<0.05) and Water 40K and Sediment 238U (r=-0.69, p<0.05). Comparison using Mann-Whitney U test shows that, soil and sediment are similar in their specific activities with Z values of -0.408, -1.209 and -1.021 (p > 0.05) for 40K, 232Th and 238U respectively. The concentration of solid samples (soil and sediment) is different from the liquid (water) samples. These associations can be attributed to some specific underlying factors. And in other to understand them there is need for more studies.
Resumo:
Background: Perimembranous Ventricular Septal Defect (PMVSD) is the most common subtype of ventricular septal defects. Transcatheter closure of PMVSD is a challenging procedure in management of moderate or large defects. Objectives: The purpose of this study was to show that transcatheter closure of perimembranous ventricular septal defect with Amplatzer Ductal Occluder (ADO) is an effective and safe method. Patients and Methods: Between April 2012 and April 2013, 28 patients underwent percutaneous closure of PMVSD using ADO. After obtaining the size of VSD from the ventriculogram a device at least 2 mm larger than the narrowest diameter of VSD at right ventricular side was chosen. The device deployed after confirmation of its good position by echocardiography and left ventriculography. Follow up evaluations were done 1 month, 6 months, 12 months and yearly after discharge with transthoracic echocardiography and 12 lead electrocardiography. Results: The mean age of patients at procedure was 4.7 ± 6.3 (range 2 to 14) years, mean weight 14.7 ± 10.5 (range 10 to 40) kg. The mean defect size of the right ventricular side was 4.5 ± 1.6 mm. The average device size used was 7.3 ± 3.2mm (range 4 to 12 mm). The ADOs were successfully implanted in all patients. The VSD occlusion rate was 65.7% at completion of the procedure, rising up to 79.5% at discharge and 96.4% during follow-up. Small residual shunts were seen at completion of the procedure, but they disappeared during follow-up in all but one patient. The mean follow-up period was 8.3 ± 3.6 months (range 1 to 18 months). Complete atrioventricular block (CAVB), major complication or death was not observed in our study. Conclusions: Transcatheter closure of PMVSD with ADO in children is a safe and effective treatment associated with excellent success and closure rates, but long-term follow-up in a large number of patients would be warranted.