2 resultados para Pull-out-test
em Bioline International
Resumo:
Objective: To estimate the prevalence and factors associated with the performance of mammography and pap smear test in women from the city of Maringá, Paraná. Methods: Population-based cross-sectional study conducted with 345 women aged over 20 years in the period from March 2011 to April 2012. An interview was carried out using a questionnaire proposed by the Ministry of Health, which addressed sociodemographic characteristics, risk factors for chronic noncommunicable diseases and issues related to mammographic and pap screening. Data were analyzed using bivariate analysis, crude analysis with odds ratio (OR) and chi-squared test using Epi Info 3.5.1 program; multivariate analysis using logistic regression was performed using the software Statistica 7.1, with a significance level of 5% and a confidence interval of 95%. Results: The mean age of the women was 52.19 (±5.27) years. The majority (56.5%) had from 0 to 8 years of education. Additionally, 84.6% (n=266) of the women underwent pap smear and 74.3% (n=169) underwent mammography. The lower performance of pap smear test was associated with women with 9-11 years of education (p=0.01), and the lower performance of mammography was associated with women without private health insurance (p<0.01). Conclusion: The coverage of mammography and pap smear test was satisfactory among the women from Maringá, Paraná. Low education level and women who depended on the public health system presented lower performance of mammography.
Resumo:
Background: Nosocomial sepsis (NS) in newborns (NBs) is associated with high mortality rates and low microbial recovery rates. To overcome the latter problem, new techniques in molecular biology are being used. Objectives: To evaluate the diagnostic efficacy of SeptiFast test for the diagnosis of nosocomial sepsis in the newborn. Materials and Methods: 86 blood specimens of NBs with suspected NS (NOSEP-1 Test > 8 points) were analyzed using Light Cycler SeptiFast (LC-SF) a real-time multiplex PCR instrument. The results were analyzed with the Roche SeptiFast Identification Software. Another blood sample was collected to carry out a blood culture (BC). Results: Sensitivity (Sn) and specificity (Sp) of 0.69 and 0.65 respectively, compared with blood culture (BC) were obtained for LC-SF. Kappa index concordance between LC-SF and BC was 0.21. Thirteen (15.11%) samples were BC positive and 34 (31.39%) were positive with LC-SF tests. Conclusions: Compared with BC, LC-SF allows the detection of a greater number of pathogenic species in a small blood sample (1 mL) with a shorter response time.